We report here a simple, rapid, homogeneous fluorescence assay, the molecular beacon assay, for the detection and quantification of sequence-specific DNA-binding proteins. The central feature of the assay is the protein-dependent association of two DNA fragments each containing about half of a DNA sequence defining a protein-binding site. Protein-dependent association of DNA fragments can be detected by any proximity-based spectroscopic signal, such as fluorescence resonance energy transfer (FRET) between fluorochromes introduced into these DNA molecules. The assay is fully homogeneous and requires no manipulations aside from mixing of the sample and the test solution. It offers flexibility with respect to the mode of signal detection and the fluorescence probe, and is compatible with multicolor simultaneous detection of several proteins. The assay can be used in research and medical diagnosis and for high-throughput screening of drugs targeted to DNA-binding proteins.
We report here development of a rapid, homogeneous, aptamer-based fluorescence assay ("molecular beacons") for detecting proteins. The assay involves protein-induced coassociation of two aptamers recognizing two distinct epitopes of the protein. The aptamers contain short fluorophore-labeled complementary "signaling" oligonucleotides attached to the aptamer by non-DNA linker. Coassociation of the two aptamers with the protein results in bringing the two "signaling" oligonucleotides into proximity, producing a large change of fluorescence resonance energy transfer between the fluorophores. We used thrombin as a model system to provide proof-of-principle evidence validating this molecular beacon design. Thrombin beacon was capable of detecting the protein with high selectivity (also in complex biological mixtures), picomolar sensitivity, and high signal-to-background ratio. This is a homogeneous assay requiring no sample manipulation. Since the design of molecular beacons described here is not limited to any specific protein, it will be possible to develop these beacons to detect a variety of target proteins of biomedical importance.
During transcription initiation by bacterial RNA polymerase, the sigma subunit recognizes the -35 and -10 promoter elements; free sigma, however, does not bind DNA. We selected ssDNA aptamers that strongly and specifically bound free sigma(A) from Thermus aquaticus. A consensus sequence, GTA(C/T)AATGGGA, was required for aptamer binding to sigma(A), with the TA(C/T)AAT segment making interactions similar to those made by the -10 promoter element (consensus sequence TATAAT) in the context of RNA polymerase holoenzyme. When in dsDNA form, the aptamers function as strong promoters for the T. aquaticus RNA polymerase sigma(A) holoenzyme. Recognition of the aptamer-based promoters depends on the downstream GGGA motif from the aptamers' common sequence, which is contacted by sigma(A) region 1.2 and directs transcription initiation even in the absence of the -35 promoter element. Thus, recognition of bacterial promoters is controlled by independent interactions of sigma with multiple basal promoter elements.
Luminescence resonance energy transfer measurements were used to show that binding of E. coli core RNA polymerase induced major changes in interdomain distances in the sigma 70 subunit. The simplest model describing core-induced changes in sigma 70 involves a movement of the conserved region 1 by approximately 20 A and the conserved region 4.2 by approximately 15 A with respect to conserved region 2. The core-induced movement of region 1 (autoinhibition domain) and region 4.2 (DNA-binding domain) provides structural rationale for allosteric regulation of sigma 70 DNA binding properties by the core and suggests that this regulation may not only involve directly the autoinhibition domain of sigma 70 but also could involve a modulation of spacing between DNA-binding domains of sigma 70 induced by binding of core RNAP.
We describe here a new homogeneous antibody-based protein sensor design (molecular pincers) that allows rapid and sensitive detection of a specific protein in solution. In the presence of the target protein these sensors produce fluorescence signal derived from target-dependent annealing of short complementary fluorochrome-labeled oligonucleotides attached to a pair of target-specific antibodies via nanometer-scale flexible linkers. The sensors allow near-instantaneous detection of the target with sensitivity and specificity approaching that of enzyme-linked immunosorbent assay (ELISA) but requiring no sample manipulation other then the addition of the sample to the sensor mix. We used cardiac troponin I and C-reactive protein as the targets to validate these desirable properties of the sensors. Due to the availability of antibodies to thousands of interesting targets and the straightforward design blueprint of the sensors we expect their wide-ranging applications in research and medical diagnosis, especially when simplicity, high throughput, and short detection time are essential.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.