In contrast to the whole liver, primary hepatocytes are highly immunogenic. Thus, alternative strategies of immunomodulation after hepatocyte transplantation are of special interest. Silencing of HLA class I expression is expected to reduce the strength of allogeneic immune responses and to improve graft survival. In this study, primary human hepatocytes (PHH) were isolated using a two‐step‐collagenase perfusion‐technique and co‐cultured with allogeneic lymphocytes in terms of a mixed lymphocyte hepatocyte culture. Expression of HLA class I on PHH was silenced using lentiviral vectors encoding for β2‐microglobulin‐specific short hairpin RNA (shβ2m) or non‐specific shRNA (shNS) as control. The delivery of shβ2m into PHH caused a decrease by up to 96% in β2m transcript levels and a down‐regulation of HLA class I cell surface expression on PHH by up to 57%. Proliferative T cell alloresponses against HLA‐silenced PHH were significantly lower than those observed form fully HLA‐expressing PHH. In addition, significantly lower secretion of pro‐inflammatory cytokines was observed. Levels of albumin, urea and aspartate‐aminotransferase did not differ in supernatants of cultured PHH. In conclusion, silencing HLA class I expression on PHH might represent a promising approach for immunomodulation in the transplant setting without compromising metabolic function of silenced hepatocytes.
Animal welfare remains a very important issue in the livestock sector, but monitoring animal welfare in an objective and continuous way remains a serious challenge. Monitoring animal welfare, based upon physiological measurements instead of the audio–visual scoring of behaviour, would be a step forward. One of the obvious physiological signals related to welfare and stress is heart rate. The objective of this research was to measure heart rate (beat per minutes) in pigs with technology that soon will be affordable. Affordable heart rate monitoring is done today at large scale on humans using the Photo Plethysmography (PPG) technology. We used PPG sensors on a pig′s body to test whether it allows the retrieval of a reliable heart rate signal. A continuous wavelet transform (CWT)-based algorithm is developed to decouple the cardiac pulse waves from the pig. Three different wavelets, namely second, fourth and sixth order Derivative of Gaussian (DOG), are tested. We show the results of the developed PPG-based algorithm, against electrocardiograms (ECG) as a reference measure for heart rate, and this for an anaesthetised versus a non-anaesthetised animal. We tested three different anatomical body positions (ear, leg and tail) and give results for each body position of the sensor. In summary, it can be concluded that the agreement between the PPG-based heart rate technique and the reference sensor is between 91% and 95%. In this paper, we showed the potential of using the PPG-based technology to assess the pig′s heart rate.
Introduction Despite advances in perioperative management and surgical technique, postoperative liver failure remains a feared complication after hepatic resection. Various supportive treatment options are under current discussion, but lack of structured evaluation. We therefore established a porcine model of major liver resection to study regeneration after partial hepatectomy in a reliable and well-defined pre-clinical setting. Methods Major hepatectomy was performed on seven minipigs with the intention to set up a non-lethal but relevant transient impairment of liver function. For steady postoperative vascular access (e.g. for blood withdrawal, measurement of venous pressure), permanent catheters were implanted into the internal jugular and portal veins, respectively. Animals were followed up for 30 days; clinical and laboratory results were recorded in detail. Monitoring was enhanced by non-invasive determination of the maximum liver function capacity (LiMAx test). Results and conclusions The established porcine model appeared suitable for evaluation of postoperative liver regeneration. Clinical characteristics and progression of liver function impairment as well as subsequent recovery were comparable to courses known from surgery in humans. Laboratory parameters (e.g. liver enzymes, bilirubin, INR, coagulation factor II) showed relevant derangements during postoperative days (POD) 0 to 3 followed by normalization until POD 7. Application of the LiMAx test was feasible in minipigs, again showing values comparable to humans and kinetics in line with obtained laboratory parameters. The exteriorized portal vein catheters enabled intra- and postoperative monitoring of portal venous pressures as well as easy access for blood withdrawal without relevant risk of postoperative complications.
Animal welfare remains a very important issue in the livestock sector but monitoring animal welfare in an objective and continuous way remains a serious challenge. Monitoring animal welfare based upon physiological measurements instead of audio-visual scoring of behaviour would be a step forward. One of the obvious physiological signals related to welfare and stress is heart rate. The objective of this research was to measure heart rate (beat per minutes) on pigs with technology that soon will be affordable. Affordable heart rate monitoring is done today at large scale on humans using the Photo Plethysmography (PPG) technology. We used PPG sensors on pig’s body to test whether it allows getting reliable heart rate signal. A continuous wavelet transform (CWT)-based algorithm is developed to decouple the cardiac pulse waves from the pig. Three different wavelets, namely 2nd, 4th and 6th order Derivative of Gaussian (DOG, are tested. We show results of the developed PPG-based algorithm against electrocardiograms (ECG) as a reference measure for heart rate and this for an anesthetized versus a non-anesthetised animal. We tested three different anatomical body positions (ear, leg and tail) and give results for each body position of the sensor. In summary, it can be concluded that the agreement between PPG-based heart rate technique and reference sensor goes from 91 to 95 percentage. In this paper we showed the potential of using the PPG-based technology to assess pig’s hear rate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.