To examine whether transplantation of human mesenchymal stem cells (MSCs) could reconstruct the corneal damage and also whether grafted MSCs could differentiate into corneal epithelial cells, we isolated MSCs from healthy donors. After growth and expansion on amniotic membrane, cells were transplanted into rat corneas 7 days after chemical burns. Reconstruction of the damaged cornea and the rat vision were measured once a week by slit lamp and by an optokinetic head-tracking instrument, respectively. Corneas were then cut out, fixed, and imbedded for immunofluorescent study of the expression of keratin 3 and keratin-pan as epithelial cell markers. Expression of CD45, interleukin 2, and metalloproteinase-2 was also investigated for inflammation and inflammation-related angiogenesis. The data showed that transplantation of MSCs, like limbal epithelial stem cells, successfully reconstructed damaged rat corneal surface. Interestingly, the therapeutic effect of the transplantation may be associated with the inhibition of inflammation and angiogenesis after transplantation of MSCs rather than the epithelial differentiation from MSCs. This study provides the first line of evidence that MSCs can be used for reconstruction of damaged corneas, presenting a new source for autotransplantation in the treatment of corneal disorders. STEM CELLS 2006;24:315-321
Targeted cell delivery by a magnetically actuated microrobot with a porous structure is a promising technique to enhance the low targeting efficiency of mesenchymal stem cell (MSC) in tissue regeneration. However, the relevant research performed to date is only in its proof-of-concept stage. To use the microrobot in a clinical stage, biocompatibility and biodegradation materials should be considered in the microrobot, and its efficacy needs to be verified using an in vivo model. In this study, we propose a human adipose–derived MSC–based medical microrobot system for knee cartilage regeneration and present an in vivo trial to verify the efficacy of the microrobot using the cartilage defect model. The microrobot system consists of a microrobot body capable of supporting MSCs, an electromagnetic actuation system for three-dimensional targeting of the microrobot, and a magnet for fixation of the microrobot to the damaged cartilage. Each component was designed and fabricated considering the accessibility of the patient and medical staff, as well as clinical safety. The efficacy of the microrobot system was then assessed in the cartilage defect model of rabbit knee with the aim to obtain clinical trial approval.
Purpose The purpose of this study was to assess, in anterior cruciate ligament (ACL)-injured and -uninjured population, tibial plateau anatomic variables [medial and lateral tibial plateau slopes (MTPS and LTPS) and medial tibial plateau depth (MTPD)] on conventional magnetic resonance imaging (MRI) using a novel combined method and to determine whether these variables are risk factors for ACL injury. Methods Seventy-three isolated ACL-injury patients (20 women and 53 men) were compared with 51 control group patients (19 women and 32 men). Results The combined method had very high interrater and intrarater reliability compared with previously described methods. LTPS was significantly steeper in the overall injured group and injured men compared with the control group, with odds ratio (OR) of 3.031 and 5.89, respectively. Women with ACL injury had significantly shallower MTPD than uninjured women, with OR of 4.13. Conclusions We conclude that the new combined method is accurate and reproducible for assessing the tibial plateau anatomy. Women with shallower MTPD and men with steeper LTPS are at higher risk of sustaining ACL injury. Overall, steeper LTPS is a significant risk factor for sustaining ACL injury.
BackgroundThis study compared clinical and radiological results between robotic total knee arthroplasty (TKA) and conventional TKA with a cruciate-retaining implant at 10-year follow-up. The hypothesis was that robotic TKA would allow for more accurate leg alignment and component placement, and thus enhance clinical and radiological results and long-term survival rates.MethodsA total of 113 primary TKAs performed using a cruciate-retaining implant in 102 patients from 2004 to 2007 were reviewed retrospectively. Of the 113 TKAs, 71 were robotic TKAs and 42 were conventional TKAs. Clinical outcomes (visual analogue scale pain score, Hospital for Special Surgery score, Western Ontario and McMaster University score, range of motion, and complications), radiological outcomes, and long-term survival rates were evaluated at a mean follow-up of 10 years.ResultsClinical outcomes and long-term survival rates were similar between the two groups. Regarding the radiological outcomes, the robotic TKA group had significantly fewer postoperative leg alignment outliers (femoral coronal inclination, tibial coronal inclination, femoral sagittal inclination, tibial sagittal inclination, and mechanical axis) and fewer radiolucent lines than the conventional TKA group.ConclusionsBoth robotic and conventional TKAs resulted in good clinical outcomes and postoperative leg alignments. Robotic TKA appeared to reduce the incidence of leg alignment outliers and radiolucent lines compared to conventional TKA.
We studied 58 knees that underwent anterior cruciate ligament (ACL) reconstruction using a patella tendon autograft. The mean age at reconstruction was 30.4 (18-58) years, and the average follow-up was 11.2 (8.6-13.8) years. The presence of osteoarthritis was assessed radiographically using Kellgren and Lawrence's classification. Osteoarthritis was detected in the medial compartment in 25 cases and in the lateral compartment in 14 cases. Significant independent predictors of osteoarthritis were: accompanying meniscal injury [odds ratio (OR) 9.19), p<0.001], an interval of more than 6 months from injury to reconstruction (OR 4.77, p=0.021), and age more than 25 years at reconstruction (OR 3.37, p=0.034). However, no statistically significant correlation was found between the development of osteoarthritis and clinical outcome or radiological stability.
This study provides a robust measuring method of the femoral neck anteversion angle for use in a total hip replacement pre-planning program. The femora of 24 patients (69.3 +/- 6.3 years old) were CT-scanned and converted into three-dimensionally volume-rendered models in ORTHODOC (ISS Inc., CA, USA) which is the pre-planning software for ROBODOC surgery. The Mod.ISS method (the modified ISS method), designed by authors, measures the anteversion angle of the proximal-most femoral neck confluence on the plane perpendicular to the femoral mechanical axis. 3D FNC method proposed by the authors of the present study involves measurement of the anteversion angle of three-dimensional femoral neck center on a plane perpendicular to the posterior femoral plane and parallel to the posterior condylar axis. Here, we found that interobserver reproducibility was 1.8 degrees (SD = 1.3) for the Mod.ISS method and 2.4 (SD = 1.9) for the proposed 3D FNC method. The anteversion angle of the local femoral neck axis was measured as theta = 25.3(L/D) + [corrected] 5.4 in L/D = 0.1-0.6, where L/D is distance (L) from the proximal-most neck confluence along the femoral mechanical axis, normalized with respect to the diameter of the femoral head (D). At L/D = 0.5, the anteversion angle of the femoral neck axis was coincident with the average femoral neck anteversion determined by the 3D FNC method. We conclude that the 3D FNC method is a gold standard for measuring the femoral neck anteversion applicable during both pre-operative and post-operative stages, because its femoral neck center can be determined in three-dimensional space during both stages.
Our results indicate that distal chevron osteotomy with a distal soft tissue procedure provides an effective and reliable means of correcting moderate to severe hallux valgus deformity, and that it does so with high levels of patient satisfaction and low incidence of complications.
Background The intent of double-bundle anterior cruciate ligament reconstruction is to reproduce the normal anterior cruciate ligament anatomy and improve knee joint rotational stability. However, no consensus has been reached on the advantages of this technique over the single-bundle technique. Hypothesis We hypothesized that double-bundle anterior cruciate ligament reconstruction could provide better intraoperative stability and clinical outcome than single-bundle reconstruction. Type of study Cohort study; Level of evidence, 2. Methods Forty patients with anterior cruciate ligament injury in one knee were recruited; 20 were allocated to a double-bundle anterior cruciate ligament reconstruction group and 20 to a single-bundle anterior cruciate ligament reconstruction group. Intraoperative stabilities at 30° of knee flexion were compared between the 2 groups using a navigation system. Clinical outcomes including Lysholm knee scores, Tegner activity scores, Lachman and pivot-shift test results, and radiographic stabilities were also compared between the 2 groups after a minimum of 2 years of follow-up. Results Intraoperative anterior and rotational stabilities after anterior cruciate ligament reconstruction in the double-bundle group were significantly better than those in single-bundle group (P = .020 and P < .001, respectively). Nineteen patients (95%) in each group were available at a minimum 2-year follow-up. Clinical outcomes including Lysholm knee and Tegner activity scores were similar in the 2 groups at 2-year follow-up (P > .05). Furthermore, stability results of the Lachman and pivot-shift tests, and radiologic findings at 2-year follow-up failed to reveal any significant intergroup differences (P > .05). Conclusion Although double-bundle anterior cruciate ligament reconstruction produces better intraoperative stabilities than single-bundle anterior cruciate ligament reconstruction, the 2 modalities were found to be similar in terms of clinical outcomes and postoperative stabilities after a minimum of 2 years of follow-up.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.