Interictal ripples propagate across iEEG contacts in children with MRE. The association between the onset-ripple-zone resection and good outcome indicates that onset-ripples are promising epilepsy biomarkers, which estimate the epileptogenic tissue better than spread-ripples or onset-spikes. Ann Neurol 2018;84:331-346.
BACKGROUNDA critical conceptual step in epilepsy surgery is to locate the causal region of seizures. In practice, the causal region may be inferred from the set of electrodes showing early ictal activity. There would be advantages in deriving information about causal regions from interictal data as well. We applied Granger's statistical approach to baseline interictal data to calculate causal interactions. We hypothesized that maps of the Granger causality network (or GC maps) from interictal data might inform about the seizure network, and set out to see if “causality” in the Granger sense correlated with surgical targets.OBJECTIVETo determine whether interictal baseline data could produce GC maps, and whether the regions of high GC would statistically resemble the topography of the ictally active electrode (IAE) set and resection.METHODSTwenty-minute interictal baselines obtained from 25 consecutive patients were analyzed. The “GC maps” were quantitatively compared to conventionally constructed surgical plans, by using rank order and Cartesian distance statistics.RESULTSIn 16 of 25 cases, the interictal GC rankings of the electrodes in the IAE set were lower than predicted by chance (P < .05). The aggregate probability of such a match by chance alone is very small (P < 10−20) suggesting that interictal GC maps correlated with ictal networks. The distance of the highest GC electrode to the IAE set and to the resection averaged 4 and 6 mm (Wilcoxon P < .001).CONCLUSIONGC analysis has the potential to help localize ictal networks from interictal data.
The results suggest that the human intracranial system shows frequency dependence as seen in animal experiments. There is an inverse relationship between CPA index and ICP amplitude, indicating that higher amplitudes may occur with a reduced performance of the pulsation absorber. Our findings show that frequency dependence can be observed in humans and imply that reduced frequency-dependent compliance may be responsible for elevated ICP amplitude observed in patients who respond to CSF shunting.
BACKGROUND
Thermal flow evaluation (TFE) is a non-invasive method to assess ventriculoperitoneal shunt function. Flow detected by TFE is a negative predictor of the need for revision surgery. Further optimization of testing protocols, evaluation in multiple centers, and integration with clinical and imaging impressions prompted the current study.
OBJECTIVE
To compare the diagnostic accuracy of 2 TFE protocols, with micropumper (TFE+MP) or without (TFE-only), to neuro-imaging in patients emergently presenting with symptoms concerning for shunt malfunction.
METHODS
We performed a prospective multicenter operator-blinded trial of a consecutive series of patients who underwent evaluation for shunt malfunction. TFE was performed, and preimaging clinician impressions and imaging results were recorded. The primary outcome was shunt obstruction requiring neurosurgical revision within 7 d. Non-inferiority of the sensitivity of TFE vs neuro-imaging for detecting shunt obstruction was tested using a prospectively determined a priori margin of −2.5%.
RESULTS
We enrolled 406 patients at 10 centers. Of these, 68/348 (20%) evaluated with TFE+MP and 30/215 (14%) with TFE-only had shunt obstruction. The sensitivity for detecting obstruction was 100% (95% CI: 88%-100%) for TFE-only, 90% (95% CI: 80%-96%) for TFE+MP, 76% (95% CI: 65%-86%) for imaging in TFE+MP cohort, and 77% (95% CI: 58%-90%) for imaging in the TFE-only cohort. Difference in sensitivities between TFE methods and imaging did not exceed the non-inferiority margin.
CONCLUSION
TFE is non-inferior to imaging in ruling out shunt malfunction and may help avoid imaging and other steps. For this purpose, TFE only is favored over TFE+MP.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.