Background UW Medicine was one of the first health systems to encounter and treat COVID-19 patients in the United States, starting in late February 2020. Objective Here we describe the rapid rollout of capabilities by UW Medicine Information Technology Services (ITS) to support our clinical response to the COVID-19 pandemic and provide recommendations for health systems to urgently consider, as they plan their own response to this and potentially other future pandemics. Methods Our recommendations include establishing a hospital incident command structure that includes tight integration with IT, creating automated dashboards for incident command, optimizing emergency communication to staff and patients, and preparing human resources, security, other policies, and equipment to support the transition of all nonessential staff to telework. We describe how UW Medicine quickly expanded telemedicine capabilities to include most primary care providers and increasing numbers of specialty providers. We look at how we managed expedited change control processes to quickly update electronic health records (EHR) with new COVID-19 laboratory and clinical workflows. We also examine the integration of new technology such as tele-intensive care (ICU) equipment and improved integration with teleconferencing software into our EHR. To
Nano-optic imagers that modulate light at sub-wavelength scales could enable new applications in diverse domains ranging from robotics to medicine. Although metasurface optics offer a path to such ultra-small imagers, existing methods have achieved image quality far worse than bulky refractive alternatives, fundamentally limited by aberrations at large apertures and low f-numbers. In this work, we close this performance gap by introducing a neural nano-optics imager. We devise a fully differentiable learning framework that learns a metasurface physical structure in conjunction with a neural feature-based image reconstruction algorithm. Experimentally validating the proposed method, we achieve an order of magnitude lower reconstruction error than existing approaches. As such, we present a high-quality, nano-optic imager that combines the widest field-of-view for full-color metasurface operation while simultaneously achieving the largest demonstrated aperture of 0.5 mm at an f-number of 2.
Holography is arguably the most promising technology to provide wide field-of-view compact eyeglasses-style near-eye displays for augmented and virtual reality. However, the image quality of existing holographic displays is far from that of current generation conventional displays, effectively making today's holographic display systems impractical. This gap stems predominantly from the severe deviations in the idealized approximations of the "unknown" light transport model in a real holographic display, used for computing holograms. In this work, we depart from such approximate "ideal" coherent light transport models for computing holograms. Instead, we learn the deviations of the real display from the ideal light transport from the images measured using a display-camera hardware system. After this unknown light propagation is learned, we use it to compensate for severe aberrations in real holographic imagery. The proposed hardware-in-the-loop approach is robust to spatial, temporal and hardware deviations, and improves the image quality of existing methods qualitatively and quantitatively in SNR and perceptual quality. We validate our approach on a holographic display prototype and show that the method can fully compensate unknown aberrations and erroneous and non-linear SLM phase delays, without explicitly modeling them. As a result, the proposed method significantly outperforms existing state-of-the-art methods in simulation and experimentation - just by observing captured holographic images.
Nearly every commodity imaging system we directly interact with, or indirectly rely on, leverages power efficient, application-adjustable black-box hardware image signal processing (ISPs) units, running either in dedicated hardware blocks, or as proprietary software modules on programmable hardware. The configuration parameters of these black-box ISPs often have complex interactions with the output image, and must be adjusted prior to deployment according to application-specific quality and performance metrics. Today, this search is commonly performed manually by "golden eye" experts or algorithm developers leveraging domain expertise. We present a fully automatic system to optimize the parameters of black-box hardware and software image processing pipelines according to any arbitrary (i.e., application-specific) metric. We leverage a differentiable mapping between the configuration space and evaluation metrics, parameterized by a convolutional neural network that we train in an end-to-end fashion with imaging hardware in-the-loop. Unlike prior art, our differentiable proxies allow for high-dimension parameter search with stochastic first-order optimizers, without explicitly modeling any lower-level image processing transformations. As such, we can efficiently optimize black-box image processing pipelines for a variety of imaging applications, reducing application-specific configuration times from months to hours. Our optimization method is fully automatic, even with black-box hardware in the loop. We validate our method on experimental data for real-time display applications, object detection, and extreme low-light imaging. The proposed approach outperforms manual search qualitatively and quantitatively for all domain-specific applications tested. When applied to traditional denoisers, we demonstrate that---just by changing hyperparameters---traditional algorithms can outperform recent deep learning methods by a substantial margin on recent benchmarks.
High-dynamic range (HDR) imaging is an essential imaging modality for a wide range of applications in uncontrolled environments, including autonomous driving, robotics, and mobile phone cameras. However, existing HDR techniques in commodity devices struggle with dynamic scenes due to multi-shot acquisition and postprocessing time, e.g. mobile phone burst photography, making such approaches unsuitable for real-time applications. In this work, we propose a method for snapshot HDR imaging by learning an optical HDR encoding in a single image which maps saturated highlights into neighboring unsaturated areas using a diffractive optical element (DOE). We propose a novel rank-1 parameterization of the DOE which drastically reduces the optical search space while allowing us to efficiently encode high-frequency detail. We propose a reconstruction network tailored to this rank-1 parametrization for the recovery of clipped information from the encoded measurements. The proposed end-to-end framework is validated through simulation and real-world experiments and improves the PSNR by more than 7 dB over state-ofthe-art end-to-end designs.
Most modern commodity imaging systems we use directly for photography—or indirectly rely on for downstream applications—employ optical systems of multiple lenses that must balance deviations from perfect optics, manufacturing constraints, tolerances, cost, and footprint. Although optical designs often have complex interactions with downstream image processing or analysis tasks, today’s compound optics are designed in isolation from these interactions. Existing optical design tools aim to minimize optical aberrations, such as deviations from Gauss’ linear model of optics, instead of application-specific losses, precluding joint optimization with hardware image signal processing (ISP) and highly parameterized neural network processing. In this article, we propose an optimization method for compound optics that lifts these limitations. We optimize entire lens systems jointly with hardware and software image processing pipelines, downstream neural network processing, and application-specific end-to-end losses. To this end, we propose a learned, differentiable forward model for compound optics and an alternating proximal optimization method that handles function compositions with highly varying parameter dimensions for optics, hardware ISP, and neural nets. Our method integrates seamlessly atop existing optical design tools, such as Zemax . We can thus assess our method across many camera system designs and end-to-end applications. We validate our approach in an automotive camera optics setting—together with hardware ISP post processing and detection—outperforming classical optics designs for automotive object detection and traffic light state detection. For human viewing tasks, we optimize optics and processing pipelines for dynamic outdoor scenarios and dynamic low-light imaging. We outperform existing compartmentalized design or fine-tuning methods qualitatively and quantitatively, across all domain-specific applications tested.
Purpose Quantification of myocardial perfusion has the potential to improve the detection of regional and global flow reduction. Significant effort has been made to automate the workflow, where one essential step is the arterial input function (AIF) extraction. Failure to accurately identify the left ventricle (LV) prevents AIF estimation required for quantification, therefore high detection accuracy is required. This study presents a robust LV detection method using the convolutional neural network (CNN). Methods CNN models were trained by assembling 25,027 scans (N = 12,984 patients) from three hospitals, seven scanners. Performance was evaluated using a hold‐out test set of 5721 scans (N = 2805 patients). Model inputs were a time series of AIF images (2D+T). Two variations were investigated: (1) two classes (2CS) for background and foreground (LV mask), and (2) three classes (3CS) for background, LV, and RV. The final model was deployed on MRI scanners using the Gadgetron reconstruction software framework. Results Model loading on the MRI scanner took ~340 ms and applying the model took ~180 ms. The 3CS model successfully detected the LV in 99.98% of all test cases (1 failure out of 5721). The mean Dice ratio for 3CS was 0.87 ± 0.08 with 92.0% of all cases having Dice >0.75. The 2CS model gave a lower Dice ratio of 0.82 ± 0.22 (P < 1e−5). There was no significant difference in foot‐time, peak‐time, first‐pass duration, peak value, and area‐under‐curve (P > .2) comparing automatically extracted AIF signals with signals from manually drawn contours. Conclusions A CNN‐based solution to detect the LV blood pool from the arterial input function image series was developed, validated, and deployed. A high LV detection accuracy of 99.98% was achieved.
Holographic displays promise to deliver unprecedented display capabilities in augmented reality applications, featuring a wide field of view, wide color gamut, spatial resolution, and depth cues all in a compact form factor. While emerging holographic display approaches have been successful in achieving large étendue and high image quality as seen by a camera, the large étendue also reveals a problem that makes existing displays impractical: the sampling of the holographic field by the eye pupil. Existing methods have not investigated this issue due to the lack of displays with large enough étendue, and, as such, they suffer from severe artifacts with varying eye pupil size and location. We show that the holographic field as sampled by the eye pupil is highly varying for existing display setups, and we propose pupil-aware holography that maximizes the perceptual image quality irrespective of the size, location, and orientation of the eye pupil in a near-eye holographic display. We validate the proposed approach both in simulations and on a prototype holographic display and show that our method eliminates severe artifacts and significantly outperforms existing approaches.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.