One year after surgery, TE shows better results than the BGI. The final IOP, IOP reduction and failure rate are similar, but the need for additional IOP lowering medication in the BGI group is higher as well as the complication rate. The increased risk of developing diplopia after placement of a BGI must be taken into consideration.
Purpose: Although the Baerveldt glaucoma implant (BGI) initially was reserved for refractory glaucoma, its role in the surgical management of glaucoma has shifted towards a primary treatment choice. We performed a randomized prospective study to compare BGI surgery and trabeculectomy (TE) in patients without previous ocular surgery. Methods: We included 119 glaucoma patients without previous ocular surgery. One eye of each subject was randomized to either a BGI or TE. Follow-up visits were at 1 day, 2 weeks, 6 weeks, 3 months, 6 months and 1, 2, 3, 4 and 5 years postoperatively. Primary outcomes were intraocular pressure (IOP) and failure rate. Secondary outcomes were medication, anterior chamber laser flare value and complications. Results: After 5 years, an IOP of 12.7 AE 3.9 mmHg (mean AE SD) was achieved in the TE group and 12.9 AE 3.9 mmHg in the BGI group. We found no statistically significant difference in failure rate between the groups (p = 0.72). More BGI patients needed additional medication to control their IOP (85%; 1.9 AE 1.2 types of glaucoma medication) compared to the TE patients (57%; 0.5 AE 0.9 types of glaucoma medication). Diplopia was significantly more present in the BGI group than in the TE group (27% versus 4%; p < 0.001). The self-limiting complication rate was similar in both groups. Conclusions: Our study demonstrates that, in the long term, the final IOP and failure rate are similar after TE and BGI surgery. However, the need for additional medication after BGI surgery is higher than after TE. Also, the increased risk of developing diplopia after BGI surgery must be taken into consideration.
PurposeThe purpose of this study was to quantify any diplopia and motility changes after the implantation of a Baerveldt glaucoma implant (BGI) or after trabeculectomy (TE).MethodsWe analyzed 51 patients with a BGI and 52 patients with a TE from a prospective cohort study. To quantify any diplopia, we asked patients about the presence of diplopia at 1 year after surgery. To quantify any ocular motility changes, we measured ductions in eight gaze directions, the patients' ocular alignment and their fusion range before and 1 year after surgery.ResultsIn the BGI group, 14 patients (28%) experienced diplopia compared with one patient (2%) in the TE group (P < 0.001). Duction changes were more commonly observed in the BGI group (35%) than in the TE group (19%). In the BGI group, ductions were mostly restricted in elevation (13%; P < 0.001), in abduction (13%), in elevation in 25° adduction (13%; P = 0.044), and in elevation in 25° abduction (25%; P < 0.001). In 32% of the patients, their near horizontal ocular alignment shifted, notably in exodirection (P = 0.04). The fusion range decreased significantly in the horizontal direction (−12.6° ± 10.3°, mean ± standard deviation; P = 0.01).ConclusionsBGI surgery was significantly associated with postoperative diplopia and impaired eye motility (reduced ductions), mostly present in abduction, elevation, elevation in 25° adduction, and elevation in 25° abduction. Even without impaired ductions, diplopia could come about.Translational RelevanceBy studying diplopia across glaucoma patients prospectively with diplopia questionnaires and extensive orthoptic measurements, we gain better insight into its occurrence.
Corneal guttae, which are the abnormal growth of extracellular matrix in the corneal endothelium, are observed in specular images as black droplets that occlude the endothelial cells. To estimate the corneal parameters (endothelial cell density [ECD], coefficient of variation [CV], and hexagonality [HEX]), we propose a new deep learning method that includes a novel attention mechanism (named fNLA), which helps to infer the cell edges in the occluded areas. The approach first derives the cell edges, then infers the well-detected cells, and finally employs a postprocessing method to fix mistakes. This results in a binary segmentation from which the corneal parameters are estimated. We analyzed 1203 images (500 contained guttae) obtained with a Topcon SP-1P microscope. To generate the ground truth, we performed manual segmentation in all images. Several networks were evaluated (UNet, ResUNeXt, DenseUNets, UNet++, etc.) and we found that DenseUNets with fNLA provided the lowest error: a mean absolute error of 23.16 [cells/mm$$^{2}$$ 2 ] in ECD, 1.28 [%] in CV, and 3.13 [%] in HEX. Compared with Topcon’s built-in software, our error was 3–6 times smaller. Overall, our approach handled notably well the cells affected by guttae, detecting cell edges partially occluded by small guttae and discarding large areas covered by extensive guttae.
Purpose: To determine whether the postoperative corneal endothelial cell density (ECD) differs between glaucoma patients who underwent Baerveldt implant (BGI) surgery and patients who underwent a trabeculectomy (TE) over 5 years ago. Methods: Cross-sectional, observational study including 34 patients who underwent TE and 36 patients who underwent BGI surgery 5-11 years ago, as part of a randomized clinical trial. None of the patients had a history of intraocular surgery prior to their glaucoma surgery. Central and peripheral ECD was measured by using a non-contact specular microscope. Results: Central and peripheral ECD in the TE group was 2285 AE 371 cells/ mm 2 (mean AE SD) and 2463 AE 476 cells/mm 2 , respectively. Central and peripheral ECD in the BGI group was 1813 AE 745 cells/mm 2 and 1876 AE 764 cells/mm 2 , respectively. The central and peripheral ECD was statistically significantly higher in the TE group than in the BGI group (p = 0.001 for both). Additional intraocular surgical interventions were more prevalent in the BGI group (23) than in the TE group (5) (p < 0.001). In a subanalysis, without eyes that had undergone additional surgical interventions, only the peripheral ECD was statistically significantly higher in the TE group compared with the BGI group (p = 0.011). For the BGI group, a longer postoperative period resulted in a lower central ECD (r = À0.614, p = 0.004). Conclusion: Long-term ECD in eyes that underwent a BGI was considerably lower compared with eyes that underwent a TE, mainly in the peripheral cornea. This suggests that BGI causes a larger decrease of ECD than TE. Additionally, the decrease after BGI appears to continue for a longer period than after TE.
Purpose To assess if ocular motility impairment, and the ensuing diplopia, after Baerveldt Glaucoma device (BGI) implantation, is related to the presence of a large fluid reservoir (bleb), using Magnetic Resonance Imaging (MRI). Methods In a masked observational study (CCMO-registry number: NL65633.058.18), the eyes of 30 glaucoma patients with (n = 12) or without diplopia (n = 18) who had previously undergone BGI implantation were scanned with a 7 Tesla MRI-scanner. The substructures of the BGI-complex, including both blebs and plate, were segmented in 3D. Primary outcomes were a comparison of volume and height of the BGI-complex between patients with and without diplopia. Comparisons were performed by using an unpaired t-test, Fisher’s Exact or Mann-Whitney test. Correlations were determined by using Spearman correlation. Results The median volume and height of the BGI-complex was significantly higher in patients with compared to patients without diplopia (p = 0.007 and p = 0.025, respectively). Six patients had an excessively large total bleb volume (median of 1736.5mm3, interquartile range 1486.3–1933.9mm3), four of whom experienced diplopia (33% of the diplopia patients). Fibrotic strands through the BGI plate, intended to limit the height of the bleb, could be visualized but were not related to diplopia (75% versus 88%; p = 0.28). Conclusions With MRI, we show that in a significant number of diplopia cases a large bleb is present in the orbit. Given the large volume of these blebs, they are a likely explanation of the development of diplopia in at least some of the patients with diplopia after BGI implantation. Additionally, the MR-images confirm the presence of fibrotic strands. As these strands are also visible in patients with a large bleb, they are apparently not sufficient to restrict the bleb height.
To estimate the corneal endothelial parameters from specular microscopy images depicting cornea guttata (Fuchs dystrophy), we propose a new deep learning methodology that includes a novel attention mechanism named feedback non-local attention (fNLA). Our approach first infers the cell edges, then selects the cells that are well detected, and finally applies a postprocessing method to correct mistakes and provide the binary segmentation from which the corneal parameters are estimated ( cell density [ECD], coefficient of variation [CV], and hexagonality [HEX]). In this study, we analyzed 1203 images acquired with a Topcon SP-1P microscope, 500 of which contained guttae. Manual segmentation was performed in all images. We compared the results of different networks (UNet, ResUNeXt, DenseUNets, UNet++) and found that DenseUNets with fNLA provided the best performance, with a mean absolute error of 23.16 [cells/mm 2 ] in ECD, 1.28 [%] in CV, and 3.13 [%] in HEX, which was 3-6 times smaller than the error obtained by Topcon's built-in software. Our approach handled the cells affected by guttae remarkably well, detecting cell edges occluded by small guttae while discarding areas covered by large guttae. Overall, the proposed method obtained accurate estimations in extremely challenging specular images.
Purpose To investigate the effect of two surgical techniques in primary Baerveldt glaucoma implant (BGI) surgery, that is the sutured technique and the unsutured (free) plate technique, on the ocular motility and prevalence of diplopia. We hypothesize that the free plate technique results in a lower diplopia prevalence. Methods We performed a prospective study of patients who underwent BGI surgery with the free plate technique and compared them with patients from a previous study who had undergone BGI surgery with the sutured technique. Their ductions, ocular alignment and fusion range and the prevalence of diplopia were measured before surgery and at 3 months, 6 months and 1 year postoperatively. Results We analysed 57 free plate and 51 sutured plate patients. One year postoperatively, we found no statistically significant difference in the prevalence of diplopia between the two techniques. All duction changes between baseline and 1‐year follow‐up were restrictions and occurred statistically significantly more frequently in the free plate than in the sutured plate group (p = 0.03; 60% versus 34%). About the ocular alignment, in the horizontal direction, a change in exodirection was more common in both groups, while in the vertical direction, a hyperdeviation of the operated eye was more common. The vertical ocular alignment change was smaller in the free plate group than in the sutured plate group (p = 0.04 at near and p = 0.02 at distance). Conclusions One year postoperatively, the prevalence of diplopia was not significantly different between patients with the sutured plate and patients with the free plate technique. Both surgical techniques induce diplopia and changes in ocular motility and/or in ocular alignment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.