The French energy company EDF has experienced in the last years some problems in managing reactor coolant pumps (RCP) seals in operation. That’s why a thermo-elasto-hydrodynamical model of the seal has been developed. The present model is a steady two-dimensional approach so as to characterize the normal operating mode of the seal. Numerical results are successfully compared to experimental results of leak-flow rate. The influence of pressure drop and injection temperature is described. The influence of the conicity of the faceplates is underlined. The friction is introduced in the model in order to reproduce the hysteretic behavior of the seal. The development of this model leads to a better knowledge of the behavior of a critical component.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.