The attenuating properties of several types of lead (Pb)-based and non-Pb radiation shielding materials were studied and a correlation was made of radiation attenuation, materials properties, calculated spectra and ambient dose equivalent. Utilizing the well-characterized x-ray and gamma ray beams at the National Research Council of Canada, air kerma measurements were used to compare a variety of commercial and pre-commercial radiation shielding materials over mean energy ranges from 39 to 205 keV. The EGSnrc Monte Carlo user code cavity. cpp was extended to provide computed spectra for a variety of elements that have been used as a replacement for Pb in radiation shielding garments. Computed air kerma values were compared with experimental values and with the SRS-30 catalogue of diagnostic spectra available through the Institute of Physics and Engineering in Medicine Report 78. In addition to garment materials, measurements also included pure Pb sheets, allowing direct comparisons to the common industry standards of 0.25 and 0.5 mm "lead equivalent." The parameter "lead equivalent" is misleading, since photon attenuation properties for all materials (including Pb) vary significantly over the energy spectrum, with the largest variations occurring in the diagnostic imaging range. Furthermore, air kerma measurements are typically made to determine attenuation properties without reference to the measures of biological damage such as ambient dose equivalent, which also vary significantly with air kerma over the diagnostic imaging energy range. A single material or combination cannot provide optimum shielding for all energy ranges. However, appropriate choice of materials for a particular energy range can offer significantly improved shielding per unit mass over traditional Pb-based materials.
The use of Monte Carlo simulations in diagnostic medical imaging research is widespread due to its flexibility and ability to estimate quantities that are challenging to measure empirically. However, any new Monte Carlo simulation code needs to be validated before it can be used reliably. The type and degree of validation required depends on the goals of the research project, but, typically, such validation involves either comparison of simulation results to physical measurements or to previously published results obtained with established Monte Carlo codes. The former is complicated due to nuances of experimental conditions and uncertainty, while the latter is challenging due to typical graphical presentation and lack of simulation details in previous publications. In addition, entering the field of Monte Carlo simulations in general involves a steep learning curve. It is not a simple task to learn how to program and interpret a Monte Carlo simulation, even when using one of the publicly available code packages. This Task Group report provides a common reference for benchmarking Monte Carlo simulations across a range of Monte Carlo codes and simulation scenarios. In the report, all simulation conditions are provided for six different Monte Carlo simulation cases that involve common x-ray based imaging research areas. The results obtained for the six cases using four publicly available Monte Carlo software packages are included in tabular form. In addition to a full description of all simulation conditions and results, a discussion and comparison of results among the Monte Carlo packages and the lessons learned during the compilation of these results are included. This abridged version of the report includes only an introductory description of the six cases and a brief example of the results of one of the cases. This work provides an investigator the necessary information to benchmark his/her Monte Carlo simulation software against the reference cases included here before performing his/her own novel research. In addition, an investigator entering the field of Monte Carlo simulations can use these descriptions and results as a self-teaching tool to ensure that he/she is able to perform a specific simulation correctly. Finally, educators can assign these cases as learning projects as part of course objectives or training programs.
This article describes an efficiency study of directional bremsstrahlung splitting (DBS) for x-ray tube modeling. DBS is shown to be up to five or six orders of magnitude more efficient at 50 or 135 kV tube potential than a simulation without splitting, and 60 times more efficient compared to uniform bremsstrahlung splitting. A methodology is presented to determine the optimum splitting number for a given situation using a second degree polynomial expression derived from theoretical considerations. Very large optimum splitting numbers are found for small fields (5 mm radius) at 1 m from the x-ray source, which are relevant for half-value layer (HVL) calculations and for simulations related to primary air kerma standards. Two approaches for the calculation of kerma at a plane and inside a volume using track-length estimation are implemented in BEAMnrc, a user-code from the EGSnrc Monte Carlo simulation system for photon and electron transport. A practical application of DBS to HVL calculations for a Comet MXR-320 x-ray tube is reported. The agreement with measured HVLs at different constant tube potentials is found to be better than 2.3%.
Effects of changes in the physics of EGSnrc compared to EGS4/PRESTA on energy deposition kernels for monoenergetic photons and on dose point kernels for beta sources in water are investigated. In the diagnostic energy range, Compton binding corrections were found to increase the primary energy fraction up to 4.5% at 30 keV with a corresponding reduction of the scatter component of the kernels. Rayleigh scattered photons significantly increase the scatter component of the kernels and reduce the primary energy fraction with a maximum 12% reduction also at 30 keV where the Rayleigh cross section in water has its maximum value. Sampling the photo-electron angular distribution produces a redistribution of the energy deposited by primaries around the interaction site causing differences of up to 2.7 times in the backscattered energy fraction at 20 keV. Above the pair production threshold, the dose distribution versus angle of the primary dose component is significantly different from the EGS4 results. This is related to the more accurate angular sampling of the electron-positron pair direction in EGSnrc as opposed to using a fixed angle approximation in default EGS4. Total energy fractions for photon beams obtained with EGSnrc and EGS4 are almost the same within 0.2%. This fact suggests that the estimate of the total dose at a given point inside an infinite homogeneous water phantom irradiated by broad beams of photons will be very similar for kernels calculated with both codes. However, at interfaces or near boundaries results can be very different especially in the diagnostic energy range. EGSnrc calculated kernels for monoenergetic electrons (50 keV, 100 keV, and 1 MeV) and beta spectra (32P and 90Y) are in excellent agreement with reported EGS4 values except at 1 MeV where inclusion of spin effects in EGSnrc produces an increase of the effective range of electrons. Comparison at 1 MeV with an ETRAN calculation of the electron dose point kernel shows excellent agreement.
The EGSnrc Monte Carlo simulation system is used to obtain, for 10 plane-parallel ionization chambers in 60Co beams, the correction factors Kcomp and Pwall that account for the nonequivalence of the chamber wall material to the buildup cap and the phantom material, respectively. A more robust calculation method has been used compared to that used in previous works. A minor conceptual error related to the axial nonuniformity correction factor, Kan, has been identified and shown to have an effect of about 0.2%. The assumption that Pwall in-phantom is numerically equal to Kcomp calculated for a water buildup cap is shown to be accurate to better than 0.06%, thereby justifying the use of Kcomp calculations which are much more efficient. The effect on the calculated dose to the air in the cavity of the particle production threshold and transport energies used in the simulations is studied. Uncertainties in the calculated correction factors due to uncertainties in the photon and electron cross-section data are studied. They are 0.14% and 0.24%, respectively (1 standard deviation), for Kcomp factors. The uncertainties on Kwall factors are 0.03% from photon cross-section uncertainties and negligible from electron cross-section uncertainties. A comparison with previous EGS4/PRESTA calculations shows that present results are systematically higher by an average of 0.8%, ranging from 0.4% up to 1.4%. The present results are in better agreement with reported experimental values.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.