Purpose Computed tomography (CT) examinations, often using high-radiation dosages, are increasingly used in the acute management of polytrauma patients. This study compares a low-dose polytrauma multi-phase whole-body CT (WBCT) protocol on a latest generation of 16-cm detector 258-slice multi-detector CT (MDCT) scanner with advanced dose reduction techniques to a single-phase polytrauma WBCT protocol on a 64-slice MDCT scanner. Methods Between March and September 2015, 109 polytrauma patients (group A) underwent acute WBCT with a low-dose multi-phase WBCT protocol on a 258-slice MDCT whereas 110 polytrauma patients (group B) underwent single-phase trauma CT on a 64-slice MDCT. The diagnostic accuracy to trauma-related injuries, radiation dose, quantitative and semiquantitative image quality parameters, subjective image quality scorings, and workflow time parameters were compared. Results In group A, statistically significantly more arterial injuries (p = 0.04) and arterial dissections (p = 0.002) were detected. In group A, the mean (±SD) dose length product value was 1681 ± 183 mGy*cm and markedly lower when compared to group B (p < 0.001). The SDs of the mean Houndsfield unit values of the brain, liver, and abdominal aorta were lower in group A (p < 0.001). Mean signal-tonoise ratios (SNRs) for the brain, liver, and abdominal aorta were significantly higher in group A (p < 0.001). Group A had significantly higher image quality scores for all analyzed anatomical locations (p < 0.02). However, the mean time from patient registration until completion of examination was significantly longer for group A (p < 0.001). Conclusions The low-dose multi-phase CT protocol improves diagnostic accuracy and image quality at markedly reduced radiation. However, due to technical complexities and surplus electronic data provided by the newer low-dose technique, examination time increases, which reduces workflow in acute emergency situations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.