Introduction: There is a great variety of orthodontic brackets in the Brazilian market, and constantly evaluating them is critical for professionals to know their properties, so as to be able to choose which product best suits their clinical practice. Objectives:To evaluate the bond strength and the adhesive remnant index (ARI) of different brands of metal brackets. Material and Methods:A total of 105 bovine incisors were used, and brackets of different brands were bonded to teeth. Seven different bracket brands were tested (MorelliTM, American OrthodonticsTM, TP OrthodonticsTM, Abzil-3MTM, OrthometricTM, TecnidentTM and UNIDENTM). Twenty-four hours after bonding, shear bond strength test was performed; and after debonding, the ARI was determined by using an optical microscope at a 10-fold increase. Results: Mean shear bond strength values ranged from 3.845 ± 3.997 (MorelliTM) to 9.871 ± 5.106 MPa (TecnidentTM). The majority of the ARI index scores was 0 and 1. Conclusion:Among the evaluated brackets, the one with the lowest mean shear bond strength values was MorelliTM. General evaluation of groups indicated that a greater number of bond failure occurred at the enamel/adhesive interface.
Aim: The aim of this study was to evaluate the influence of acrylic resin immersion in different mouthwashes on hardness, roughness and color. Methods: Specimens of an orthodontic selfcured acrylic resin (Orto Clas ®) were produced and immersed in five mouthwashes: Plax ® Classic (Colgate ®); Plax ® alcohol-free (Colgate ®); Listerine ® (Johnson & Johnson ®); Periogard ® (Colgate ®) and Periogard ® alcohol-free (Colgate ®). Nine different immersion times were studied:
OBJECTIVE: To evaluate the response of elastomeric ligatures in several colors for a 4 mm traction over time. METHODS: Morelli® elastomeric ligatures, were submitted to traction forces using two rods of circular cross section, until a 4 mm distance was reached, matching the approximate diameter of an upper central incisor bracket of the same manufacturer. The ligatures were kept in artificial saliva immersion at 37 ºC. Forces levels were measured immediately (0 h), 2, 4, 6, 8, 10, 12, 24, 48, 72, 96 hours, 1, 2, 3, 4 weeks and results were submitted to two-way repeated-measures ANOVA statistical analysis. RESULTS: The gray samples showed the higher initial values of tensile strength. The lowest values were presented by purple, light pink, green, black and red groups. The greater tensile strength instability was presented by red, black, silver, green and gray groups. The greater tensile strength stability was presented by deep pink, dark blue, blue, purple and light pink groups. CONCLUSION: Elastomeric ligatures do not present stable behavior when suffering traction forces over time and different colors display different behaviors. Deep pink, dark blue, blue, purple and light pink groups, displayed the most stable forces, suggesting that they should be used during the treatment to obtain constant forces
Purpose: To evaluate the influence of peracetic acid immersion on water sorption, solubility and microhardness of heat and self-cured acrylic resins.Methods: Thirty specimens of each type of acrylic resin were produced for sorption, solubility and microhardness evaluation. Sorption and solubility were evaluated based on ISO1567. For the microhardness test, specimens (20.0×5.0×10.0 mm) were made and evaluated under a 100 g load for 15 s. The test groups were submitted to a peracetic acid 0.2% immersion for 10 minutes. Data of sorption and solubility were analyzed by two way ANOVA and, hardness values, by paired t-test.Results: Values of sorption and solubility were in agreement with ISO1567 requirements to both groups and ranged, in μg/mm 3 , for sorption from 22.28 (±4.40) to 24.25 (±3.27), and from 1.09 (±0.16) to 1.29 (±0.10) for solubility. Solubility showed a statistically significant difference between the two types of resin at test group. There was no statistical significant difference at the microhardness values.Conclusion: In this study, immersion in peracetic acid solution 0.2% showed no alterations at acrylic resin properties tested.Peracetic acid could be recommended to replace the conventional agents for the disinfection of acrylic resin devices.Key words: Acrylic resin; denture cleanser; prosthodontics ResumoObjetivo: Avaliar a influência da imersão em ácido peracético sobre a sorção, solubilidade e microdureza de resinas acrílicas termo e autopolimerizada.Metodologia: Trinta corpos de prova de cada resina acrílica foram confeccionados para avaliação da sorção, solubilidade e microdureza. A sorção e a solubilidade foram avaliadas de acordo com a ISO 1567. Para a determinação da microdureza, os corpos de prova (20×5×10 mm) foram confeccionados e avaliados com uma carga de 100 g por 15 s. Os grupos teste foram imersos em ácido peracético 0,2% por 10 minutos. Os dados de sorção e solubilidade foram analisados com ANOVA de duas vias e de dureza por teste t pareado.Resultados: Os valores de sorção e solubilidade ficaram de acordo com as especificações da ISO 1567 para ambos os grupos e no ensaio de sorção variaram entre 22,28 (±4,40) até 24,25 (±3,27), e de 1,09 (±0,16) até 1,29 (±0,10) para solubilidade, em μg/mm 3 . A solubilidade apresentou diferença estatisticamente significativa entre os dois tipos de resina após imersão em ácido peracético. Os valores de microdureza não apresentaram diferença estatisticamente significativa entre os grupos.Conclusão: A imersão em ácido peracético 0,2% não alterou as propriedades avaliadas das resinas acrílicas.
Objective: The objective of this study was to evaluate the behavior of intra-arch latex elastic of different brands and colors when subjected to disinfection procedures. Methods: A total of 320 units of American Orthodontics elastic; Morelli and Uniden were selected and divided into four groups according to the performed disinfection process: autoclave -15 minutes; hypochlorite -20 minutes; glutaraldehyde -30 minutes and control. The disinfecting agents and the disinfection time were defined by a prior microbiological test. Before and after disinfection, by means of a universal trial machine, the maximum generated strength -until the rupture occurred -was evaluated. Results: The autoclave disinfection reduced significantly the strength generated by elastic, in 75% of the brands. The disinfection in hypochlorite increased significantly the strength generated by Morelli elastic; probably the alteration to its elastic property increased its rigidity. Neither the Yellow Uniden nor the American elastic suffered any significant reduction in strength as the result of hypochlorite disinfection. The glutaraldehyde was the disinfectant solution with less significant effect on the strength of the bands, affecting only the Green Uniden. Conclusion:The results suggest that the 2% glutaraldehyde is the disinfectant less aggressive to the elastic performance.
<p><strong>Introdução:</strong> As principais análises cefalométricas utilizadas para o planejamento do tratamento ortodôntico são baseadas nas características da população de raça branca, no entanto as características morfológicas parecem diferir entre os diferentes grupos étnicos. Assim, não parece lógico que os planos de tratamento de pacientes melanodermas sejam baseados em análises cefalométricas com valores de normalidade para leucodermas. <strong>Objetivos: </strong>Avaliar se há diferenças nas medidas cefalométricas entre leucodermas e melanodermas e quais os valores de normalidade para os melanodermas. <strong>Metodologia:</strong> revisão de publicações científicas que apresentem as características esqueléticas, dentárias e tegumentares de indivíduos melanodermas e leucodermas até o presente momento através de descritores específicos. <strong>Resultados:</strong> os melanodermas apresentam medidas cefalométricas que indicam a maxila e mandíbula avançadas em relação à base do crânio, um plano mandibular mais inclinado, terço inferior da face aumentado, maior convexidade facial, incisivos superiores protruídos e levemente proclinados, incisivos inferiores acentuadamente protruídos e proclinados, lábios superior e inferior mais proeminentes, quando comparados aos leucodermas. <strong>Conclusão:</strong> existem diferenças entre as medidas cefalométricas de leucodermas e melanodermas e isso deve ser levado em consideração nos tratamentos ortodônticos no momento do planejamento e da análise dos resultados.<strong>RESUMO</strong></p><p class="PriscilaCxSpMiddle"> </p><p class="PriscilaCxSpLast"> </p>
<p><strong>Introdução:</strong> A proposta deste estudo foi comparar medidas cefalométricas, lineares e angulares, obtidas de cefalogramas sobre telerradiografias de perfil digitais e reconstruções tomográficas, no plano médio sagital, a partir da tomografia computadorizada de feixe cônico (TCFC). <strong>Materiais e métodos:</strong> Foram selecionadas 108 documentações iniciais de pacientes ortodônticos que continham telerradiografia de perfil digital e tomografia computadorizada de feixe cônico. Para reconstrução tomográfica a largura da base do osso nasal foi adotada como padrão para definição da espessura a ser utilizada. O examinador determinou 17 pontos anatômicos no plano médio sagital para a obtenção de 16 medidas cefalométricas utilizando o Dolphin Imaging Cephalometric and Tracing Software sobre os dois exames analisados. <strong>Resultados:</strong> A análise de reprodutividade do examinador foi feita através do coeficiente de correlação intraclasse (ICC) e constatou-se excelente reprodutibilidade (ICC <span style="text-decoration: underline;">></span> 0,75) para todas as medidas cefalométricas utilizadas. A média das medidas cefalométricas no plano médio sagital, dos dois tipos de exames, foram submetidas ao teste t pareado e ao teste de Wilcoxon quando não foi obtida normalidade dos dados. Do total de medidas analisadas 9 (nove) foram diferentes estatisticamente, entre os dois grupos: SNA, SNB, SND, 1.NA, S-L, N-Me e SN apresentaram valores de p<0,01 enquanto Pog-NB e S-Li apresentaram valor de p<0,05. <strong>Conclusões:</strong> O estudo mostrou que houve diferenças significativas entre as medidas cefalométricas no plano médio sagital obtidas a partir da telerradiografia digital e a tomografia computadorizada de feixe cônico quando utilizada a base do osso nasal como referência de espessura para a reconstrução tomográfica. </p>
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.