Background: Four-dimensional flow magnetic resonance imaging (4D flow MRI) can accurately visualize and quantify flow and provide hemodynamic information such as wall shear stress (WSS). This imaging technique can be used to obtain more insight in the hemodynamic changes during cardiac cycle in the true and false lumen of uncomplicated acute Type B Aortic Dissection (TBAD). Gaining more insight of these forces in the false lumen in uncomplicated TBAD during optimal medical treatment, might result in prediction of adverse outcomes. Methods: A porcine aorta dissection model with an artificial dissection was positioned in a validated ex-vivo circulatory system with physiological pulsatile flow. 4D flow MR images with 3 set heartrates (HR; 60 bpm, 80 bpm and 100 bpm) were acquired. False lumen volume per cycle (FLV), mean and peak systolic WSS were determined from 4D flow MRI data. For validation, the experiment was repeated with a second porcine aorta dissection model. Results: During both experiments an increase in FLV (initial experiment: ΔFLV = 2.05 ml, p < 0.001, repeated experiment: ΔFLV = 1.08 ml, p = 0.005) and peak WSS (initial experiment: ΔWSS = 1.2 Pa, p = 0.004, repeated experiment: ΔWSS = 1.79 Pa, p = 0.016) was observed when HR increased from 60 to 80 bpm. Raising the HR from 80 to 100 bpm, no significant increase in FLV ( p = 0.073, p = 0.139) was seen during both experiments. The false lumen mean WSS increased significant during initial (2.71 to 3.85 Pa; p = 0.013) and non-significant during repeated experiment (3.22 to 4.00 Pa; p = 0.320). Conclusion: 4D flow MRI provides insight into hemodynamic dimensions including WSS. Our ex-vivo experiments showed that an increase in HR from 60 to 80 bpm resulted in a significant increase of FLV and WSS of the false lumen. We suggest that strict heart rate control is of major importance to reduce the mean and peak WSS in uncomplicated acute TBAD. Because of the limitations of an ex-vivo study, 4D flow MRI will have to be performed in clinical setting to determine whether this imaging model would be of value to predict the course of uncomplicated TBAD.
Background: Hemodynamics, dissection morphology, and aortic wall elasticity have a major influence on the pressure in the false lumen. In contrast to aortic wall elasticity, the influence of hemodynamics and dissection morphology have been investigated often in multiple in vitro and ex vivo studies. The purpose of this study was to evaluate the influence of aortic wall elasticity on the diameter and pressure of the false lumen in aortic dissection. Methods: An artificial dissection was created in 3 ex vivo porcine aortas. The aorta models were consecutively positioned in a validated in vitro circulatory system with physiological pulsatile flow. Each model was imaged with ultrasound on 4 positions along the aorta and the dissection. At these 4 locations, pressure measurement was also performed in the true and false lumen with an arterial catheter. After baseline experiments, the aortic wall elasticity was adjusted with silicon and the experiments were repeated. Results: The aortic wall elasticity was decreased in all 3 models after siliconizing. In all 3 siliconized models, the diameters of the true and false lumen increased at proximal, mid, and distal location, while the mean arterial pressure did not significantly change. Conclusions: In this in vitro study, we showed that aortic wall elasticity is an important parameter altering the false lumen. An aortic wall with reduced elasticity results in an increased false lumen diameter in the mid and distal part of the false lumen. These results can only be transferred to corresponding clinical situations to a limited extent.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.