This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Background:
Breast implants are frequently used in cosmetic and reconstructive breast surgery. Capsular contracture, the most common long-term complication, is usually graded using the Baker classification. Despite its widespread use, the reliability of the Baker classification has never been established. The aim of this study was to determine the interobserver reliability and agreement of the Baker classification.
Methods:
Sixty women who had undergone cosmetic breast augmentation were included. They were examined independently by two plastic surgeons from an observer pool. The Baker score was determined, along with firmness, dislocation, symmetry, and pain using four-point scales. Patients were asked to complete the BREAST-Q postaugmentation module. The interobserver reliability and agreement were calculated for all variables with a quadratic weighted kappa.
Results:
The interobserver reliability of the Baker classification was poor (kappa, 0.55; 95 percent CI, 0.37 to 0.72). Interobserver reliability of the clinical parameters firmness (0.64; 95 percent CI, 0.49 to 0.79), dislocation (0.49; 95 percent CI, 0.26 to 0.73), and symmetry (0.61; 95 percent CI, 0.34 to 0.88) was also poor. Pain scores seemed more reliable (0.72; 95 percent CI, 0.56 to 0.89); however, most patients had no pain. The interobserver agreement for the Baker score was 48 percent; in 43 percent, the observers differed one category; and in 12 percent, the difference was more than one category.
Conclusions:
Interobserver reliability and observer agreement of the Baker classification for capsular contracture were poor. Consensus about how to adequately rate the symptoms of capsular complaints is lacking. A more reliable method of measurement or description is needed, especially for scientific research purposes, to assess the long-term problems associated with breast implants.
CLINICAL QUESTION/LEVEL OF EVIDENCE:
Diagnostic, IV.
Millions of women worldwide have silicone breast implants. It has been reported that implant failure occurs in approximately a tenth of patients within 10 years, and the consequences of dissemination of silicone debris are poorly understood. Currently, silicone detection in histopathological slides is based on morphological features as no specific immunohistochemical technique is available. Here, we show the feasibility and sensitivity of stimulated Raman scattering (SRS) imaging to specifically detect silicone material in stained histopathological slides, without additional sample treatment. Histology slides of four periprosthetic capsules from different implant types were obtained after explantation, as well as an enlarged axillary lymph node from a patient with a ruptured implant.Abbreviations: CC, connected component; OPO, optical parametric oscillator; PDMS, polydimethylsiloxane; PU, polyurethane; RMSE, root mean square error; ROI, region of interest; SRS, stimulated Raman scattering.Ludo van Haasterecht and Liron Zada contributed equally to this work.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.