Ahnesjö (2020): Robust treatment planning of dose painting for prostate cancer based on ADC-to-Gleason score mappings-what is the potential to increase the tumor control probability?, Acta Oncologica,
The ion recombination is examined in parallel-plate ionization chambers in scanning proton beams at the Danish Centre for Particle Therapy and the Skandion Clinic. The recombination correction factor k s is investigated for clinically relevant energies between 70 MeV and 244 MeV for dose rates below 400 Gy min −1 in air. The Boutillon formalism is used to separate the initial and general recombination. The general recombination is compared to predictions from the numerical recombination code IonTracks and the initial recombination to the Jaffé theory. k s is furthermore calculated with the two-voltage method (TVM) and extrapolation approaches, in particular the recently proposed three-voltage (3VL) method. The TVM is in agreement with the Boutillon method and IonTracks for dose rates above 100 Gy min −1 . However, the TVM calculated k s is closer related to the Jaffé theory for initial recombination for lower dose rate, indicating a limited application in scanning light ion beams. The 3VL is in turn found to generally be in agreement with Boutillon's method. The recombination is mapped as a function of the dose rate and proton energy at the two centres using the Boutillon formalism: the initial recombination parameter was found to be A = (0.10 ± 0.01) V at DCPT and A = (0.22 ± 0.13) V at Skandion, which is in better agreement with the Jaffé theory for initial recombination than previously reported values. The general recombination parameter was estimated to m 2 = (4.7 ± 0.1) • 10 3 V 2 nA −1 cm −1 and m 2 = (7.2 ± 0.1) • 10 3 V 2 nA −1 cm −1 . Furthermore, the numerical algorithm IonTracks is demonstrated to correctly predict the initial recombination at low dose rates and the general recombination at high dose rates.
Ionization quenching in ion beam dosimetry is often related to the fluence-or dose-averaged linear energy transfer (LET). Both quantities are however averaged over a wide LET range and a mixed field of primary and secondary ions. We propose a novel method to correct the quenched luminescence in scintillators exposed to ion beams. The method uses the energy spectrum of the primaries and accounts for the varying quenched luminescence in heavy, secondary ion tracks through amorphous track structure theory. The new method is assessed against more traditional approaches by correcting the quenched luminescence response from the BCF-12, BCF-60, and 81-0084 plastic scintillators exposed to a 100 MeV pristine proton beam in order to compare the effects of the averaged LET quantities and the secondary ions. Calculations and measurements show that primary protons constitute more than 92 % of the energy deposition but account for more than 95 % of the luminescence signal in the scintilllators. The quenching corrected luminescence signal is in better agreement with the dose measurement when the secondary particles are taken into account. The Birks model provided the overall best quenching corrections, when the quenching corrected signal is adjusted for the number of free model parameters. The quenching parameter k B for the BCF-12 and BCF-60 scintillators is in agreement with literature values and was found to be k B = (10.6 ± 0.1) × 10 −2 µm keV −1 for the 81-0084 scintillator. Finally, a fluence threshold for the 100 MeV proton beam was calculated to be of the order of 10 10 cm −2 , corresponding to 110 Gy, above which the quenching increases non-linearly and the Birks model no longer is applicable.
The origin of photons emitted in optical fibres under proton irradiation has been attributed to either entirely Čerenkov radiation or light consisting of fluorescence with a substantial amount of Čerenkov radiation. The source of the light emission is assessed in order to understand why the signal from optical fibres irradiated with protons is reportedly quenching-free. The present study uses the directional emittance of Čerenkov photons in 12 MeV and 20 MeV electron beams to validate a Monte Carlo model for simulating the emittance and transmission of Čerenkov radiation in optical fibres. We show that fewer than 0.01 Čerenkov photons are emitted and guided per 225 MeV proton penetrating the optical fibre, and that the Čerenkov signal in the optical fibre is completely negligible at the Bragg peak. Furthermore, on taking the emittance and guidance of both fluorescence and Čerenkov photons into account, it becomes evident that the reported quenching-free signal in PMMA-based optical fibres during proton irradiation is due to fluorescence.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.