The design and performance of the active complex electrode (ACE1) electrical impedance tomography system for single-ended phasic voltage measurements are presented. The design of the hardware and calibration procedures allows for reconstruction of conductivity and permittivity images. Phase measurement is achieved with the ACE1 active electrode circuit which measures the amplitude and phase of the voltage and the applied current at the location at which current is injected into the body. An evaluation of the system performance under typical operating conditions includes details of demodulation and calibration and an in-depth look at insightful metrics, such as signal-to-noise ratio variations during a single current pattern. Static and dynamic images of conductivity and permittivity are presented from ACE1 data collected on tank phantoms and human subjects to illustrate the system's utility.
EIT detected in real-time dynamic changes in pulmonary ventilation and perfusion distributions. OLV to the left lung with right-sided capnothorax caused a decrease in cardiac output, arterial oxygenation and mixed venous saturation.
Electrical Impedance Tomography (EIT) is under fast development, the present paper is a review of some procedures that are contributing to improve spatial resolution and material properties accuracy, admitivitty or impeditivity accuracy. A review of EIT medical applications is presented and they were classified into three broad categories: ARDS patients, obstructive lung diseases and perioperative patients. The use of absolute EIT image may enable the assessment of absolute lung volume, which may significantly improve the clinical acceptance of EIT. The Control Theory, the State Observers more specifically, have a developed theory that can be used for the design and operation of EIT devices. Electrode placement, current injection strategy and electrode electric potential measurements strategy should maximize the number of observable and controllable directions of the state vector space. A non-linear stochastic state observer, the Unscented Kalman Filter, is used directly for the reconstruction of absolute EIT images. Historically, difference images were explored first since they are more stable in the presence of modelling errors. Absolute images require more detailed models of contact impedance, stray capacitance and properly refined finite element mesh where the electric potential gradient is high. Parallelization of the forward *
Non-invasive acquisition of the electrical heart activity through high density mapping might allow early diagnosis of heart diseases overcoming the limitations of the traditional ECG method. This study presents a BSPM system (hardware and platform) to allow users to analyze the characteristics of morphology in up to 64 simultaneous body surface potentials (BSPs) including the 12-lead ECG and vectocardiogram (VCG). The signals undergo a preprocessing step followed by the R peak detection using previously validated techniques for heart rate variability studies. In addition, embedded 3D isopotential, 3D isochrone maps and VCG planes allow researchers to investigate the heart's the electrical activity and its patterns under different heart rhythm disorders in clinical practice.
Electrical Impedance Tomography (EIT) is a technique which can image the varying electrical properties of biological tissues. For clinical use of EIT, it can be advantageous to know both tissue conductivity and permittivity. Presented is the hardware design for the pairwise current injection active complex electrode (ACE1) EIT system which measures phasic voltages for conductivity and permittivity image reconstruction. In this system, alternating current is injected on electrodes on the boundary of a domain and single-ended voltage measurements are used in image reconstructions of the domain's interior and in calculating the current applied at the electrodes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.