Q-space imaging (QSI), a diffusion MRI technique, can provide quantitative tissue architecture information at cellular dimensions not amenable by conventional diffusion MRI. By exploiting regularities in molecular diffusion barriers, QSI can estimate the average barrier spacing such as the mean axon diameter in white matter (WM). In this work, we performed ex vivo QSI on cervical spinal cord sections from healthy C57BL/6 mice at 400MHz using a custom-designed uniaxial 50T/m gradient probe delivering a 0.6 µm displacement resolution capable of measuring axon diameters on the scale of 1 µm. After generating QSI-derived axon diameter maps, diameters were calculated using histology from seven WM tracts (dorsal corticospinal, gracilis, cuneatus, rubrospinal, spinothalamic, reticulospinal, and vestibulospinal tracts) each with different axon diameters. We found QSI-derived diameters from regions drawn in the seven WM tracts (1.1 to 2.1 µm) to be highly correlated (r 2 = 0.95) with those calculated from histology (0.8 to 1.8 µm). The QSI-derived values overestimated those obtained by histology by approximately 20%, which is likely due to the presence of extracellular signal. Finally, simulations on images of synthetic circular axons and axons from histology suggest that QSI-derived diameters are informative despite diameter and axon shape variation and the presence of intra-cellular and extra-cellular signal. QSI may be able to quantify nondestructively changes in WM axon architecture due to pathology or injury at the cellular level.
Following spinal cord injury, diffusion MRI (DWI) has been shown to detect injury and functionally significant neuroprotection following treatment that otherwise would go undetected with conventional MRI. The underlying histologic correlates to directional apparent diffusion coefficients (ADC) obtained with DWI have not been determined, however, and we address this issue by directly correlating ADC values with corresponding axon morphometry in the normal rat cervical spinal cord. ADC values transverse (perpendicular) and longitudinal (parallel) to axons both correlate with axon counts, however each directional ADC reflects distinct histologic parameters. DWI may therefore be capable of providing specific histologic data regarding the integrity of white matter.
Lynx, one of the four strategic mission concepts under study for the 2020 Astrophysics Decadal Survey, provides leaps in capability over previous and planned x-ray missions and provides synergistic observations in the 2030s to a multitude of space-and ground-based observatories across all wavelengths. Lynx provides orders of magnitude improvement in sensitivity, on-axis subarcsecond imaging with arcsecond angular resolution over a large field of view, and high-resolution spectroscopy for point-like and extended sources in the 0.2-to 10-keV range. The Lynx architecture enables a broad range of unique and compelling science to be carried out mainly through a General Observer Program. This program is envisioned to include detecting the very first seed black holes, revealing the high-energy drivers of galaxy formation and evolution, and characterizing the mechanisms that govern stellar evolution and stellar ecosystems. The Lynx optics and science instruments are carefully designed to optimize the science capability and, when combined, form an exciting architecture that utilizes relatively mature technologies for a cost that is compatible with the projected NASA Astrophysics budget. © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
Objective: To perform an evidence-based review of the literature on neuroimaging techniques utilized in spinal cord injury clinical practice and research.Methods: A search of the medical literature for articles on specific neuroimaging techniques used in SCI resulted in 2,302 published reports. Review at the abstract and full report level yielded 99 clinical and preclinical articles that were evaluated in detail. Sixty nine were clinical research studies subjected to quality of evidence grading. Twenty-three articles were drawn from the pre-clinical animal model literature and used for supportive evidence. Seven review articles were included to add an element of previous syntheses of current thinking on neuroimaging topics to the committee process (the review articles were not graded for quality of evidence). A list of clinical and research questions that might be answered on a variety of neuroimaging topics was created for use in article review. Recommendations on the use of neuroimaging in spinal cord injury treatment and research were made based on the quality of evidence.Results: Of the 69 original clinical research articles covering a range of neuroimaging questions, only one was judged to provide Class I evidence, 22 provided Class II evidence, 17 Class III evidence, and 29 Class IV evidence.Recommendations: MRI should be used as the imaging modality of choice for evaluation of the spinal cord after injury. CT and plain radiography should be used to assess the bony anatomy of the spine in patients with SCI. MRI may be used to identify the location of spinal cord injury. MRI may be used to demonstrate the degree of spinal cord compression after SCI. MRI findings of parenchymal hemorrhage/ contusion, edema, and spinal cord disruption in acute and subacute SCI may contribute to the understanding of severity of injury and prognosis for neurological improvement. MRI-Diffusion Weighted Imaging may be useful in quantifying the extent of axonal loss after spinal cord injury. Functional MRI may be useful in measuring the anatomic functional/metabolic correlates of sensory-motor activities in persons with SCI. MR Spectroscopy may be used to measure the biochemical characteristics of the brain and spinal cord following SCI. Intraoperative Spinal Sonography may be used to identify spinal and spinal cord anatomy and gross pathology during surgical procedures. Further research in these areas is warranted to improve the strength of evidence supporting the use of neuroimaging modalities. Positron Emission Tomography may be used to assess metabolic activity of CNS tissue (brain and spinal cord) in patients with SCI.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.