Modest outputs of graduates by relatively few medical schools and chronic emigration contribute to low physician presence in Sub-Saharan Africa (SSA).The Sub-Saharan African Medical School Study (SAMSS) examined the challenges, innovations, and emerging trends in medical education in SSA.SAMSS identified 168 medical schools and achieved a 72% survey response rate of the 146 schools surveyed. The Study found that countries are prioritizing medical education scale up as part of health system strengthening, and identified many innovations in pre-medical preparation, the use of expatriate faculty, and creative use of scarce research support. SAMSS also noted ubiquitous faculty shortages, weak scholastic infrastructure, and limited accreditation. Trends observed include the growth of private medical schools, community-based education, and international partnerships, and the benefit of research for faculty development.Ten recommendations provide guidance for efforts to strengthen medical education in SSA. BACKGROUND
Background New approaches to ablation of atrial fibrillation (AF) include focal impulse and rotor modulation (FIRM) mapping, and initial results reported with this technique have been favorable. We sought to independently evaluate the approach by analyzing quantitative characteristics of atrial electrograms used to identify rotors and describe acute procedural outcomes of FIRM-guided ablation. Methods and Results All FIRM-guided ablation procedures (n=24; 50% paroxysmal) at University of California, Los Angeles Medical Center were included for analysis. During AF, unipolar atrial electrograms collected from a 64-pole basket catheter were used to construct phase maps and identify putative AF sources. These sites were targeted for ablation, in conjunction with pulmonary vein isolation in most patients (n=19; 79%). All patients had rotors identified (mean, 2.3±0.9 per patient; 72% in left atrium). Prespecified acute procedural end point was achieved in 12 of 24 (50%) patients: AF termination (n=1), organization (n=3), or >10% slowing of AF cycle length (n=8). Basket electrodes were within 1 cm of 54% of left atrial surface area, and a mean of 31 electrodes per patient showed interpretable atrial electrograms. Offline analysis revealed no differences between rotor and distant sites in dominant frequency or Shannon entropy. Electroanatomic mapping showed no rotational activation at FIRM-identified rotor sites in 23 of 24 patients (96%). Conclusions FIRM-identified rotor sites did not exhibit quantitative atrial electrogram characteristics expected from rotors and did not differ quantitatively from surrounding tissue. Catheter ablation at these sites, in conjunction with pulmonary vein isolation, resulted in AF termination or organization in a minority of patients (4/24; 17%). Further validation of this approach is necessary.
BACKGROUND New approaches to ablation of atrial fibrillation (AF) include focal impulse and rotor modulation (FIRM). Studies of this technology with short-term follow-up have shown favorable outcomes. OBJECTIVE The purpose of this study was to characterize the long-term results of FIRM ablation in a cohort of patients treated at 2 academic medical centers. METHODS All FIRM-guided ablation procedures (n = 43) at UCLA Medical Center and Virginia Commonwealth University Medical Center performed between January 2012 and October 2013 were included for analysis. During AF, FIRM software constructed phase maps from unipolar atrial electrograms to identify putative AF sources. These sites were targeted for ablation, along with pulmonary vein isolation in 77% of patients. RESULTS AF was paroxysmal in 56%, and 67% had prior AF ablation. All patients had rotors identified (mean 2.6 ± 1.2 per patient, 77% in LA). Prespecified acute procedural end-point was achieved in 47% of patients (n = 20): AF termination in 4, organization in 7, >10% slowing of AF cycle length in 9. Acute complications occurred in 4 patients (9.3%). At 18 ± 7 months of follow-up, 37% were free from documented recurrent AF after a 3-month blanking period; 21% were free from documented atrial tachyarrhythmias and off antiarrhythmic drugs. Multivariate analysis did not reveal any significant predictors of AF recurrence, including pattern of AF, acute procedural success, or prior failed ablation. CONCLUSION Long-term clinical results after FIRM ablation in this cohort of patients showed poor efficacy, different from previously published studies. Randomized studies are needed to evaluate the efficacy and clinical utility of this ablation approach for treating AF.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.