Radiomics relies on the extraction of a wide variety of quantitative image-based features to provide decision support. Magnetic resonance imaging (MRI) contributes to the personalization of patient care but suffers from being highly dependent on acquisition and reconstruction parameters. Today, there are no guidelines regarding the optimal pre-processing of MR images in the context of radiomics, which is crucial for the generalization of published image-based signatures. This study aims to assess the impact of three different intensity normalization methods (Nyul, WhiteStripe, Z-Score) typically used in MRI together with two methods for intensity discretization (fixed bin size and fixed bin number). The impact of these methods was evaluated on first-and second-order radiomics features extracted from brain MRI, establishing a unified methodology for future radiomics studies. Two independent MRI datasets were used. The first one (DATASET1) included 20 institutional patients with WHO grade II and III gliomas who underwent post-contrast 3D axial T1-weighted (T1w-gd) and axial T2-weighted fluid attenuation inversion recovery (T2w-flair) sequences on two different MR devices (1.5 T and 3.0 T) with a 1-month delay. Jensen-Shannon divergence was used to compare pairs of intensity histograms before and after normalization. The stability of first-order and secondorder features across the two acquisitions was analysed using the concordance correlation coefficient and the intra-class correlation coefficient. The second dataset (DATASET2) was extracted from the public TCIA database and included 108 patients with WHO grade II and III gliomas and 135 patients with WHO grade IV glioblastomas. The impact of normalization and discretization methods was evaluated based on a tumour grade classification task (balanced accuracy measurement) using five well-established machine learning algorithms. Intensity normalization highly improved the robustness of first-order features and the performances of subsequent classification models. For the T1w-gd sequence, the mean balanced accuracy for tumour grade classification was increased from 0.67 (95% CI 0.61-0.73) to 0.82 (95% CI 0.79-0.84, P = .006), 0.79 (95% CI 0.76-0.82, P = .021) and 0.82 (95% CI 0.80-0.85, P = .005), respectively, using the Nyul, WhiteStripe and Z-Score normalization methods compared to no normalization. The relative discretization makes unnecessary the use of intensity normalization for the second-order radiomics features. Even if the bin number for the discretization had a small impact on classification performances, a good compromise was obtained
Highlights An algorithm for automatic Covid-19 quantification based on 2D & 3D deep convolutional neural networks is presented. A Covid-19-specific holistic, highly compact multi-omics signature integrating imaging/clinical/ biological data and associated comorbidities for automatic patient staging is presented and evaluated. Short and Long-term prognosis for clinical resources optimization offering alternative/complementary means to facilitate triage for Covid-19 Clinically-relevant quantification and staging tool validated by comparison with clinical experts is reported.
BackgroundCombining radiotherapy (RT) with immuno-oncology (IO) therapy (IORT) may enhance IO-induced antitumor response. Quantitative imaging biomarkers can be used to provide prognosis, predict tumor response in a non-invasive fashion and improve patient selection for IORT. A biologically inspired CD8 T-cells-associated radiomics signature has been developed on previous cohorts. We evaluated here whether this CD8 radiomic signature is associated with lesion response, whether it may help to assess disease spatial heterogeneity for predicting outcomes of patients treated with IORT. We also evaluated differences between irradiated and non-irradiated lesions.MethodsClinical data from patients with advanced solid tumors in six independent clinical studies of IORT were investigated. Immunotherapy consisted of 4 different drugs (antiprogrammed death-ligand 1 or anticytotoxic T-lymphocyte-associated protein 4 in monotherapy). Most patients received stereotactic RT to one lesion. Irradiated and non-irradiated lesions were delineated from baseline and the first evaluation CT scans. Radiomic features were extracted from contrast-enhanced CT images and the CD8 radiomics signature was applied. A responding lesion was defined by a decrease in lesion size of at least 30%. Dispersion metrices of the radiomics signature were estimated to evaluate the impact of tumor heterogeneity in patient’s response.ResultsA total of 94 patients involving multiple lesions (100 irradiated and 189 non-irradiated lesions) were considered for a statistical interpretation. Lesions with high CD8 radiomics score at baseline were associated with significantly higher tumor response (area under the receiving operating characteristic curve (AUC)=0.63, p=0.0020). Entropy of the radiomics scores distribution on all lesions was shown to be associated with progression-free survival (HR=1.67, p=0.040), out-of-field abscopal response (AUC=0.70, p=0.014) and overall survival (HR=2.08, p=0.023), which remained significant in a multivariate analysis including clinical and biological variables.ConclusionsThese results enhance the predictive value of the biologically inspired CD8 radiomics score and suggests that tumor heterogeneity should be systematically considered in patients treated with IORT. This CD8 radiomics signature may help select patients who are most likely to benefit from IORT.
In this work we propose a novel deep learning based pipeline for the task of brain tumor segmentation. Our pipeline consists of three primary components: (i) a preprocessing stage that exploits histogram standardization to mitigate inaccuracies in measured brain modalities, (ii) a first prediction stage that uses the V-Net deep learning architecture to output dense, per voxel class probabilities, and (iii) a prediction refinement stage that uses a Conditional Random Field (CRF) with a bilateral filtering objective for better context awareness. Additionally, we compare the V-Net architecture with a custom 3D Residual Network architecture, trained on a multi-view strategy, and our ablation experiments indicate that V-Net outperforms the 3D ResNet-18 with all bells and whistles, while fully connected CRFs as post processing, boost the performance of both networks. We report competitive results on the BraTS 2018 validation and test set.
ObjectivesLumacaftor-ivacaftor is a cystic fibrosis transmembrane conductance regulator (CFTR) modulator known to improve clinical status in people with cystic fibrosis (CF). This study aimed to assess lung structural changes after one year of lumacaftor-ivacaftor treatment, and to use unsupervised machine learning to identify morphological phenotypes of lung disease that are associated with response to lumacaftor-ivacaftor.MethodsAdolescents and adults with CF from the French multicenter real-world prospective observational study evaluating the first year of treatment with lumacaftor-ivacaftor were included if they had pretherapeutic and follow-up chest computed tomography (CT)-scans available. CT scans were visually scored using a modified Bhalla score. A k-mean clustering method was performed based on 120 radiomics features extracted from unenhanced pretherapeutic chest CT scans.ResultsA total of 283 patients were included. The Bhalla score significantly decreased after 1 year of lumacaftor-ivacaftor (−1.40±1.53 points compared with pretherapeutic CT; p<0.001). This finding was related to a significant decrease in mucus plugging (−0.35±0.62 points; p<0.001), bronchial wall thickening (−0.24±0.52 points; p<0.001) and parenchymal consolidations (−0.23±0.51 points; p<0.001). Cluster analysis identified 3 morphological clusters. Patients from cluster C were more likely to experience an increase in percent predicted forced expiratory volume in 1 sec (ppFEV1) ≥5 under lumacaftor–ivacaftor than those in the other clusters (54% of responders versus 32% and 33%; p=0.01).ConclusionOne year treatment with lumacaftor-ivacaftor was associated with a significant visual improvement of bronchial disease on chest CT. Radiomics features on pretherapeutic CT scan may help in predicting lung function response under lumacaftor-ivacaftor.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.