The dark adaptation of drivers’ eyes at a tunnel entrance seriously affects traffic safety. This can be improved by the design of tunnel lighting. Light-Emitting Diode (LEDs) have been applied as a new type of luminaire in tunnel lighting in recent years, but at present, there are few studies on the influence of color rendering of LEDs on tunnel traffic safety, and there is no explicit indicator for the selection of appropriate color rendering parameters in tunnel lighting specifications, which has aroused researchers’ concern. In this article, several new color rendering evaluation indexes were compared, and as a result, it is considered that CRI2012 (a color difference-based color rendering index) is more suitable for evaluating the color rendering of LEDs used at tunnel entrances. The dark adaptation phenomenon was simulated in the laboratory. Four CRI2012s, three color temperatures and eight colored targets were used in the experiments. The results showed that yellow, silver and white can provide shorter reaction times, while red and brown lead to longer reaction times, which can provide a reference for the design of road and warning signs at tunnel entrances. The effect of target color on reaction time was greater than that of color rendering. Under most target colors, the higher the CRI2012, the shorter the reaction time. When designing the color rendering of the LEDs at a tunnel entrance, the value should thus be as large as possible (close to 100), and a lower color temperature value (about 2800 K) should be selected. This paper provides technical support for tunnel lighting design and a reference for tunnel lighting specifications, which is of significance to improve driving safety and avoid traffic accidents in highway tunnels.
LEDs are widely applied in highways and tunnels for their long life, low light attenuation, and being environment friendly in recent years. The influence of correlated color temperature (CCT) of LED on lighting safety has attracted people’s attention as the demand increased. In this paper, a calculation model of perception luminance of human eye considering mesopic vision and fog concentration was proposed. The influence of different CCTs on perception luminance of human eye under different levels of fog concentration and luminance was calculated and analyzed. The CCT of LED employed in the interior zone of a tunnel was selected based on the highest perception luminance in mesopic vision. Seven kinds of LEDs with different CCTs (3000–6500K) were applied in the experimental system with adjustable fog concentrations. The results showed that the main factors affecting visual perception are luminance and fog concentration. Higher luminance or lower fog concentration provides drivers with higher perception luminance. In contrast, although CCT has a less effect on perception luminance, LEDs with higher CCT (about 6500K) can provide higher perception luminance considering fog in mesopic vision. This paper provides technical support for tunnel lighting and guaranteeing traffic safety.
Infrared maritime target detection is a key technology in the field of maritime search and rescue, which usually requires high detection accuracy. Despite the promising progress of principal component analysis methods, it is still challenging to detect small targets of unknown polarity (bright or dark) with strong edge interference. Using the partial sum of tubal nuclear norm to estimate low-rank background components and weighted l1 norm to estimate sparse components is an effective method for target extraction. In order to suppress the strong edge interference, considering that the uniformity of the target scattering field is significantly higher than that of the background scattering field in the eigenvalue of the structure tensor, a prior weight based on the multidirectional uniformity of structure tensor eigenvalue was proposed and applied to the optimization model. In order to detect targets with unknown polarity, the images with opposite polarity were substituted into the optimization model, respectively, and the sparse-weight similarity is used to judge the polarity of the target. In order to make the method more efficient, the polarity judgment is made in the second iteration, and then, the false iteration will stop. The proposed method is compared with nine advanced baseline methods on 14 datasets and shows significant strong robustness, which is beneficial to engineering applications.
LED lights are widely used in highways and tunnels because of their long life, low light attenuation in recent years. The influence of color rendering (CRI) on lighting safety has attracted people's attention as the increase in demand. In this paper, the influence of different CRI on perception luminance of human eyes under different fog transmittance and different luminance was calculated and analyzed. A calculation model of human eye perception luminance considering mesopic vision and fog concentration was proposed. An experiment was conducted by observing different colored targets in a fog chamber. The results showed that yellow targets and high CRI can provide higher perception luminance and the latter is recommended for tunnel lighting in interior zone.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.