Pelvic fixation is still associated with a very high rate of mechanical failure. Major risk factors appear to be age and type of fixation. Although could not be shown to be statistically significant, failure to restore the optimal sagittal balance may be a contributing factor as well. So in conclusion, in cases with suboptimal sagittal plane correction, S2AI with polyaxial screws seem to have higher risk of short-term acute failure compared to IwL.
ObjectiveThe aim of this study was to compare the functional and radiological outcomes of vertebroplasty and kyphoplasty in patients with osteoporotic vertebra fractures.MethodsThe files of the patients who underwent vertebroplasty or kyphoplasty for osteoporotic vertebrae fractures were retrieved from the archives. Forty-three patients with complete follow-up data were included in the study group. The patients were evaluated for radiological outcomes in terms of local kyphosis angle, wedging index, compression ratio, visual analog pain scale (VAS) and Oswestry Disability Index (ODI).ResultsIn the study group, kyphoplasty was performed on 24 vertebrae of 22 patients (17 females, 5 males; mean age: 73 years) whereas vertebroplasty was applied on 24 vertebrae of 21 (16 females, 5 males; mean age: 74.7 years) patients. The mean follow-up time was 26 months. When the VAS and ODI values of the groups were analyzed, both groups showed statistically significant progress after the operation. Radiological data showed that the kyphoplasty group showed statistically significant improvement in the sagittal index values whereas the vertebroplasty group did not. The overall complication ratio was 4%.ConclusionBoth vertebroplasty and kyphoplasty are effective treatment methods for functional recovery and pain relief in osteoporotic fractures of the vertebra. Although radiological outcomes of the kyphoplasty seem to be better, this does not have any clinical relevance. We suggest vertebroplasty over kyphoplasty since it is an easier method to manage.Level of evidenceLevel III, Therapeutic study.
ObjectivePostoperative dynamic cryo-compression (DC) therapy has been proposed as a method of reducing pain and the inflammatory response in the early postoperative period after orthopedic joint reconstruction surgery. Our aim was to analyze the analgesic efficacy of DC therapy after adult lumbar spinal surgery.MethodsDC was applied for 30 minutes every 6 hours after surgery. Pain was measured by a visual analogue scale (VAS) in the preoperative period, immediately after surgery, and every 6 hours postoperatively for the first 72 hours of the hospital stay. Patients’ pain medication requirements were monitored using the patient-controlled analgesia system and patient charts. Twenty patients who received DC therapy were compared to 20 historical controls who were matched for demographic and surgical variables.
ResultsIn the postanesthesia care unit, the mean VAS back pain score was 5.87 ± 0.9 in the DC group and 6.95±1.0 (p=0.001) in the control group. The corresponding mean VAS scores for the DC vs. control groups were 3.8±1.1 vs. 5.4±0.7 (p < 0.001) at 6 hours postoperatively, and 2.7±0.7 vs. 6.25±0.9 (p<0.001) at discharge, respectively. The cumulative mean analgesic consumption of paracetamol, tenoxicam, and tramadol in the DC group vs. control group was 3,733.3±562.7 mg vs. 4,633.3±693.5 mg (p<0.005), 53.3±19.5 mg vs. 85.3±33.4 mg (p<0.005), and 63.3±83.4 mg vs. 393.3±79.9 mg (p<0.0001), respectively.
ConclusionThe results of this study demonstrated a positive association between the use of DC therapy and accelerated improvement in patients during early rehabilitation after adult spine surgery compared to patients who were treated with painkillers only.
Introduction. Polyaxial screws had been only tested according to the ASTM standards (when they were perpendicularly positioned to the rod). In this study, effects of the pedicle screws angled fixation to the rod on the mechanical properties of fixation were investigated. Materials and Method. 30 vertically fixed screws and 30 screws fixed with angle were used in the study. Screws were used in three different diameters which were 6.5 mm, 7.0 mm, and 7.5 mm, in equal numbers. Axial pull-out and flexion moment tests were performed. Test results compared with each other using appropriate statistical methods. Results. In pull-out test, vertically fixed screws, in 6.5 mm and 7.0 mm diameter, had significantly higher maximum load values than angled fixed screws with the same diameters (P < 0.01). Additionally, vertically fixed screws, in all diameters, had significantly greater stiffness according to corresponding size fixed with angle (P < 0.005). Conclusion. Fixing the pedicle screw to the rod with angle significantly decreased the pull-out stiffness in all diameters. Similarly, pedicle screw instrumentation fixed with angle decreased the minimum sagittal angle between the rod and the screw in all diameters for flexion moment test but the differences were not significant.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.