Surgery is currently considered the treatment of choice for patients with colorectal cancer liver metastases (CRLM) when resectable. The majority of these patients can also benefit from systemic chemotherapy. Recently, local or regional therapies such as thermal ablations have been used with acceptable outcomes. We searched the medical literature to identify studies and reviews relevant to radiofrequency (RF) ablation, microwave (MW) ablation and laser-induced thermotherapy (LITT) in terms of local progression, survival indexes and major complications in patients with CRLM. Reviewed literature showed a local progression rate between 2.8 and 29.7 % of RF-ablated liver lesions at 12-49 months follow-up, 2.7-12.5 % of MW ablated lesions at 5-19 months follow-up and 5.2 % of lesions treated with LITT at 6-month follow-up. Major complications were observed in 4-33 % of patients treated with RF ablation, 0-19 % of patients treated with MW ablation and 0.1-3.5 % of lesions treated with LITT. Although not significantly different, the mean of 1-, 3- and 5-year survival rates for RF-, MW- and laser ablated lesions was (92.6, 44.7, 31.1 %), (79, 38.6, 21 %) and (94.2, 61.5, 29.2 %), respectively. The median survival in these methods was 33.2, 29.5 and 33.7 months, respectively. Thermal ablation may be an appropriate alternative in patients with CRLM who have inoperable liver lesions or have operable lesions as an adjunct to resection. However, further competitive evaluation should clarify the efficacy and priority of these therapies in patients with colorectal cancer liver metastases.
In conclusion, RF and MW ablation therapy showed no significant difference in the treatment of HCC regarding the complete response, rates of residual foci of untreated disease, and recurrence rate.
• Few reports are available in the literature regarding robotic-assisted liver microwave ablation. • The robotic guided approach improved accuracy of localizing the target tumour. • Radiation dose on patients was reduced with the robotic guidance. • Numbers of insertions and readjustments were reduced, lowering chances of complications.
• X-ray volume imaging (XVI) systems are increasingly used for interventional radiological procedures. • More modern XVI systems use lower radiation doses compared with earlier counterparts. • Furthermore more modern XVI systems provide higher image quality. • Technological advances reduce radiation dose and improve image quality.
Faster CT gantry rotation reduces scan time and motion artifacts. However, accelerating rotation time increases image noise and streak artifacts. Therefore, a slower CT gantry rotation speed is still recommended for higher image quality in some cases.
More doses were obtained for hands of the procedural personnel compared to other anatomical regions measured. Catheter angiography showed lower dose compared with other imaging groups examined. Lesion delineation was clearly possible using CBCT. Objective and subjective analysis showed the opposite results regarding image quality because of higher noise levels and artefacts.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.