Gait analysis is a useful tool to understand behavioral changes in preclinical arthritis models. While observational scoring and spatiotemporal gait parameters are the most widely performed gait analyses in rodents, commercially available systems can now provide quantitative assessments of spatiotemporal patterns. However, inconsistencies remain between testing platforms, and laboratories often select different gait pattern descriptors to report in the literature. Rodent gait can also be described through kinetic and kinematic analyses, but systems to analyze rodent kinetics and kinematics are typically custom made and often require sensitive, custom equipment. While the use of rodent gait analysis rapidly expands, it is important to remember that, while rodent gait analysis is a relatively modern behavioral assay, the study of quadrupedal gait is not new. Nearly all gait parameters are correlated, and a collection of gait parameters is needed to understand a compensatory gait pattern used by the animal. As such, a change in a single gait parameter is unlikely to tell the full biomechanical story; and to effectively use gait analysis, one must consider how multiple different parameters contribute to an altered gait pattern. The goal of this article is to review rodent gait analysis techniques and provide recommendations on how to use these technologies in rodent arthritis models, including discussions on the strengths and limitations of observational scoring, spatiotemporal, kinetic, and kinematic measures. Recognizing rodent gait analysis is an evolving tool, we also provide technical recommendations we hope will improve the utility of these analyses in the future.
Locomotive changes are often associated with disease or injury, and these changes can be quantified through gait analysis. Gait analysis has been applied to preclinical studies, providing quantitative behavioural assessment with a reasonable clinical analogue. However, available gait analysis technology for small animals is somewhat limited. Furthermore, technological and analytical challenges can limit the effectiveness of preclinical gait analysis. The Gait Analysis Instrumentation and Technology Optimized for Rodents (GAITOR) Suite is designed to increase the accessibility of preclinical gait analysis to researchers, facilitating hardware and software customization for broad applications. Here, the GAITOR Suite’s utility is demonstrated in 4 models: a monoiodoacetate (MIA) injection model of joint pain, a sciatic nerve injury model, an elbow joint contracture model, and a spinal cord injury model. The GAITOR Suite identified unique compensatory gait patterns in each model, demonstrating the software’s utility for detecting gait changes in rodent models of highly disparate injuries and diseases. Robust gait analysis may improve preclinical model selection, disease sequelae assessment, and evaluation of potential therapeutics. Our group has provided the GAITOR Suite as an open resource to the research community at www.GAITOR.org, aiming to promote and improve the implementation of gait analysis in preclinical rodent models.
A promising treatment strategy for spinal cord injury (SCI) is to reduce inhibition from chondroitin sulfate proteoglycans (CSPGs). For example, administering intracellular σ peptide (ISP) can improve the ability of axons to cross inhibitory CSPGs and improve function in rodent models of SCI. To translate such treatments into the clinic, we need robust and sensitive methods for studying rodent models. In this study, we applied a newly developed suite of quantitative gait analysis tools, GAITOR (gait analysis instrumentation and technology optimized for rodents), which consists of an arena and open-source software (AGATHA: automated gait analysis through hues and areas). We showed that GAITOR can be used to detect subtle functional improvements (measured by hindlimb duty factor imbalance) in rats following ISP administration in a T10 hemisection injury model. We demonstrated that SCI-specific parameters (right paw placement accuracy and phase dispersion) can be easily added to GAITOR to track recovery. We confirmed the gait observations via retrograde tracer uptake. We concluded that GAITOR is a powerful tool for measuring recovery after moderate/mild SCI, and could be used to replace expensive/inflexible commercially-available gait analysis techniques.
Background Detecting behaviors related to orofacial pain in rodent models often relies on subjective investigator grades or methods that place the animal in a stressful environment. In this study, an operant-based behavioral assay is presented for the assessment of orofacial tactile sensitivity in the rat. New Methods In the testing chamber, rats are provided access to a sweetened condensed milk bottle; however, a 360° array of stainless steel wire loops impedes access. To receive the reward, an animal must engage the wires across the orofacial region. Contact with the bottle triggers a motor, requiring the animal to accept increasing pressure on the face during the test. To evaluate this approach, tolerated bottle distance was measured for 10 hairless Sprague-Dawley rats at baseline and 30 minutes after application of capsaicin cream (0.1%) to the face. The experiment was repeated to evaluate the ability of morphine to reverse this effect. Results The application of capsaicin cream reduced tolerated bottle distance measures relative to baseline (p<0.05). As long as morphine did not cause reduced participation due to sedation, subcutaneous morphine dosing reduced the effects of capsaicin (p<0.001). Comparison with Existing Method For behavioral tests, experimenters often make subjective decisions of an animal’s response. Operant methods can reduce these effects by measuring an animal’s selection in a reward-conflict decision. Herein, a method to measure orofacial sensitivity is presented using an operant system. Conclusions This operant device allows for consistent measurement of heightened tactile sensitivity in the orofacial regions of the rat.
Since the meniscus has limited capacity to self-repair, creating a long-lasting meniscus replacement may help reduce the incidence of osteoarthritis (OA) after meniscus damage. As a first step toward this goal, this study evaluated the mechanical integrity of a decellularized, laser drilled (LD) meniscus as a potential scaffold for meniscal engineering. To evaluate the decellularization process, 24 porcine menisci were processed such that one half remained native tissue, while the other half was decellularized in sodium dodecyl sulphate (SDS). To evaluate the laser drilling process, 24 additional menisci were decellularized, with one half remaining intact while the other half was LD. Decellularization did not affect the tensile properties, but had significant effects on the cyclic compressive hysteresis and unconfined compressive stress relaxation. Laser drilling decreased the Young's modulus and instantaneous stress during unconfined stress relaxation and the circumferential ultimate strength during tensile testing. However, the losses in mechanical integrity in the LD menisci were generally smaller than the variance observed between samples, and thus, the material properties for the LD tissue remained within a physiological range. In the future, optimization of laser drilling patterns may improve these material properties. Moreover, reseeding the construct with cells may further improve the mechanical properties prior to implantation. As such, this work serves as a proof of concept for generating decellularized, LD menisci scaffolds for the purposes of meniscal engineering.
Post-traumatic joint contracture (PTJC) is a debilitating condition, particularly in the elbow. Previously, we established an animal model of elbow PTJC quantifying passive postmortem joint mechanics and histological changes temporally. These results showed persistent motion loss similar to what is experienced in humans. Functional assessment of PTJC in our model was not previously considered; however, these measures would provide a clinically relevant measure and would further validate our model by demonstrating persistently altered joint function. To this end, a custom bilateral grip strength device was developed, and a recently established open-source gait analysis system was used to quantify forelimb function in our unilateral injury model. In vivo joint function was shown to be altered long-term and never fully recover. Specifically, forelimb strength in the injured limbs showed persistent deficits at all time points; additionally, gait patterns remained imbalanced and asymmetric throughout the study (although a few gait parameters did return to near normal levels). A quantitative understanding of these longitudinal, functional disabilities further strengthens the clinical relevance of our rat PTJC model enabling assessment of the effectiveness of future interventions aimed at reducing or preventing PTJC.
Cartilage collagen matrix loss and osteophytes were not found in any histological image; 2 therefore, these measures were not included in the table. Other values are shown as mean 3 +/-95% confidence interval (C.I.). Comparison for MIA versus saline animals at each week 4 are from the Tukey HSD test, whereas the comparison for MIA and saline animals for all 5
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.