Chimeric T. cruzi antigens have been proposed as a diagnostic tool for chronic Chagas disease (CD) in both settings where Chagas disease is endemic and those where it is not endemic. Antibody response varies in accordance to each T. cruzi strain, presenting challenges to the use of antigens lacking demonstrated cross-reactivity with Leishmania spp. Our group expressed four chimeric proteins (IBMP-8.1, IBMP-8.2, IBMP-8.3, and IBMP-8.4) and previously assessed their diagnostic performance to determine cross-reactivity with Leishmania spp. Here, we validated our findings using serum samples from different Brazilian geographic areas reporting endemic Chagas disease, endemic visceral or American cutaneous leishmaniasis (ACL), or both. Overall, 829 serum samples were evaluated using commercial and IBMP enzyme-linked immunosorbent assays. Due to the absence of a reference assay to diagnosis CD, latent class analysis (LCA) was performed through the use of a statistical model. The incidence of cross-reactivity for ACL-positive samples varied from 0.35% (IBMP-8.3) to 0.70% (IBMP-8.1 and IBMP-8.2). Regarding visceral leishmaniasis (VL)-positive samples, the IBMP-8.2 and IBMP-8.3 antigens cross-reacted with six (3.49%) and with only one sample (0.58%), respectively. No cross-reactivity with either ACL or VL was observed for the IBMP-8.4 antigen. Similarly, no cross-reactions were found when VL-positive samples were assayed with IBMP-8.1. The agreement among the results obtained using IBMP antigens ranged from 97.3% for IBMP-8.2 and 99% for IBMP-8.1 and IBMP-8.3 to 100% for IBMP-8.4, demonstrating almost perfect agreement with LCA. Accordingly, in light of the negligible cross-reactivity with both ACL and VL, we suggest the use of IBMP antigens in regions where T. cruzi and Leishmania spp. are coendemic.
Despite several available methodologies for Chagas disease (CD) serological screening, the main limitation of chronic CD diagnosis is the lack of effective tools for large-scale screening and point-of-care diagnosis to be used in different CD epidemiological scenarios. Taking into account that developing such a diagnostic tool will significantly improve the ability to identify CD carriers, we aimed at performing a proof-of-concept study (phase I study) to assess the use of these proteins in a point-of-care platform using serum samples from different geographical settings of Brazil and distinct clinical presentations. The diagnostic accuracy study was conducted on a panel of two WHO International Standards (IS) and 14 sera from T. cruzi-positive and 16 from T. cruzi-negative individuals. The results obtained with the test strips were converted to digital images, allowing quantitative comparison expressed as a relative band intensity ratio (RBI). The diagnostic potential and performance were also determined. Regardless of the geographical origin or clinical presentation, all sera with T. cruzi antibodies returned positive both for IBMP-8.1 and IBMP-8.4 chimeric antigens. The area under the ROC curve (AUC) values was 100% for both antigens, demonstrating an outstanding overall diagnostic accuracy (100%). Based on the data, we believe that the lateral flow assays based on these antigens are promising methodologies for screening CD.
Background In Brazil, acute Chagas disease (ACD) surveillance involves mandatory notification, which allows for population-based epidemiological studies. We conducted a nationwide population-based ecological analysis of the spatiotemporal patterns of ACD notifications in Brazil using secondary surveillance data obtained from the Notifiable Diseases Information System (SINAN) maintained by Brazilian Ministry of Health. Methodology/Principal findings In this nationwide population-based ecological all cases of ACD reported in Brazil between 2001 and 2018 were included. Epidemiological characteristics and time trends were analyzed through joinpoint regression models and spatial distribution using microregions as the unit of analysis. A total of 5,184 cases of ACD were recorded during the period under study. The annual incidence rate in Brazil was 0.16 per 100,000 inhabitants/year. Three statistically significant changes in time trends were identified: a rapid increase prior to 2005 (Period 1), a stable drop from 2005 to 2009 (Period 2), followed by another increasing trend after 2009 (Period 3). Higher frequencies were noted in males and females in the North (all three periods) and in females in Northeast (Periods 1 and 2) macroregions, as well as in individuals aged between 20–64 years in the Northeast, and children, adolescents and the elderly in the North macroregion. Vectorial transmission was the main route reported during Period 1, while oral transmission was found to increase significantly in the North during the other periods. Spatiotemporal distribution was heterogeneous in Brazil over time. Despite regional differences, over time cases of ACD decreased significantly nationwide. An increasing trend was noted in the North (especially after 2007), and significant decreases occurred after 2008 among all microregions other than those in the North, especially those in the Northeast and Central-West macroregions. Conclusions/Significance In light of the newly identified epidemiological profile of CD transmission in Brazil, we emphasize the need for strategically integrated entomological and health surveillance actions.
The performance of an immunoassay relies on antigen-antibody interaction; hence, antigen chemical stability and structural integrity are paramount for an efficient assay. We conducted a functional, thermostability and long-term stability analysis of different chimeric antigens (IBMP), in order to assess effects of adverse conditions on four antigens employed in ELISA to diagnose Chagas disease. ELISA-based immunoassays have served as a model for biosensors development, as both assess molecular interactions. To evaluate thermostability, samples were heated and cooled to verify heat-induced denaturation reversibility. In relation to storage stability, the antigens were analyzed at 25 °C at different moments. Long-term stability tests were performed using eight sets of microplates sensitized. Antigens were structurally analyzed through circular dichroism (CD), dynamic light scattering, SDS-PAGE, and functionally evaluated by ELISA. Data suggest that IBMP antigens are stable, over adverse conditions and for over a year. Daily analysis revealed minor changes in the molecular structure. Functionally, IBMP-8.2 and IBMP-8.3 antigens showed reactivity towards anti-T. cruzi antibodies, even after 72 h at 25 °C. Long-term stability tests showed that all antigens were comparable to the control group and all antigens demonstrated stability for one year. Data suggest that the antigens maintained their function and structural characteristics even in adverse conditions, making them a sturdy and reliable candidate to be employed in future in vitro diagnostic tests applicable to different models of POC devices, such as modern biosensors in development.
Background Enzyme-linked immunosorbent assays (ELISA) are generally the chosen test for Chagas disease (CD) diagnosis; however, its performance depends on the antigen preparation adsorbed to the solid phase, which may lead to false-positive results and cross-reactions. The use of chimeric recombinant antigens can overcome this limitation. Four chimeric antigens from Trypanosoma cruzi (IBMP-8.1, IBMP-8.2, IBMP-8.3 and IBMP-8.4) were developed and evaluated in phase I, II and III studies using indirect ELISA as diagnostic platform. However, peroxidase-labeled secondary anti-human IgG antibody, which is employed in indirect ELISAs, limits its use for the detection of species-specific and class-specific antibodies. To overcome this limitation, peroxidase-labeled antigens can be utilized, diagnosing both acute or chronic infection, in a species and immunoglobulin class-independent manner, through the use of a double-antigen sandwich ELISA (DAgS-ELISA). We aimed to evaluate and validate the diagnostic performance of the chimeric antigens IBMP-8.1, IBMP-8.2, IBMP-8.3 and IBMP-8.4 in the DAgS-ELISA platform. Methodology/Principal findings DAgS-ELISA was optimized by checkerboard titration. In phase I study, 207 positive and 205 negative samples were evaluated. Cross-reactivity to other infections was also assessed using 68 samples. The selected conditions for the tests utilized 25 ng of antigen per well and the conjugate diluted at 1:2,000 for all molecules. In the phase I study, the areas under the curve of IBMP-8.1, IBMP-8.2, IBMP-8.3 and IBMP-8.4 were 98.7%, 99.5%, 98.6% and 98.8%, respectively. Among the positive samples, IBMP-8.1 antigen classified 53 (25.6%) as false negative, IBMP-8.2, 27 (13%), IBMP-8.3, 24 (11.6%) and IBMP-8.4, 43 (20.8%), giving sensitivities of 74.4%, 87%, 88.4% and 79.2%, respectively. The only antigen that did not reach 100% specificity was IBMP-8.3, with 96.6%. IBMP-8.3 was also the only molecule to show cross-reactivity with HTLV. Conclusions/Significance DAgS-ELISA is a promising tool for immunodiagnosis, and despite the high AUC values, the performance of this assay was different from the values obtained by our group when using these antigens in the indirect ELISA, for this reason, improvements are being considered to increase the sensitivity of the DAgS-ELISA.
Background: Chagas disease (CD) serological screening at blood banks is usually performed by a single highly sensitive serological assay, with chemiluminescent immunoassays (CLIAs) being the method of choice. CLIAs employ recombinant, fusion peptides and/or chimeric antigens that selectively capture anti-Trypanosoma cruzi antibodies. However, despite high sensitivity, the ability of these tests to identify CD-positive cases should be evaluated against T. cruzi strains circulating in specific locales. Herein, we used a latent class analysis (LCA) approach employing an array of four chimeric antigens to assess the diagnostic performance of the Liaison XL Murex Chagas CLIA for the detection of anti-T. cruzi IgG in serum samples. Study Design and Methods:The study included a panel of 5014 serum samples collected from volunteer blood donors at the Hematology and Hemotherapy Foundation of the State of Bahia, submitted to anti-T. cruzi antibody detection using Liaison Chagas CLIA and LCA as a reference test in the absence of a gold standard.Results: LCA classified 4993 samples as negative, while positivity for T. cruzi antibodies was predicted in 21 samples. Compared with LCA, CLIA demonstrated sensitivity and specificity of 76.2% and 99.5%, respectively, providing an overall accuracy of 99.4%. Discussion: In blood banks lacking a de facto highly sensitive screening immunoassay, the low sensitivity offered by Liaison Chagas CLIA renders it unsuitable for standalone use in serological screening procedures for CD. Moreover, blood banks are encouraged to carefully assess the ability of diagnostic methods to identify local T. cruzi strains in circulation.
Chagas disease (CD) is among the top 10 causes of inability to blood donation. Blood donation centers screen for anti-Trypanosoma cruzi antibodies using highly sensitive immunoenzymatic (ELISA) or chemiluminescent methods, which can lead to false positive results. Since positive samples cannot be used, to avoid the loss of valuable blood donations, it is necessary to improve specificity without reducing the sensitivity of the tests used for blood screening. For this purpose, our group has developed four chimeric proteins (IBMP-8.1, IBMP-8.2, IBMP-8.3, and IBMP-8.4) that have been evaluated in phase I and II studies with high performance and low cross-reactivity rates. The study included a panel of 5,014 serum samples collected from volunteer blood donors at the Hematology and Hemotherapy Foundation of the State of Bahia (Brazil). They were subjected to the detection of anti-T. cruzi antibodies, using all four IBMP antigens individually and latent class analysis (LCA) as a reference test, since there is no gold standard test for this purpose. Considering the sample size analyzed, LCA classified 4,993 (99.6%) samples as T. cruzi-negative and 21 (0.42%) as T. cruzi-positive. Sensitivity values ranged from 85.71% for IBMP-8.1 and 90.48% for IBMP-8.2–95.24% for IBMP-8.3 and 100% for IBMP-8.4, while specificity ranged from 99.98% for IBMP-8.3 and IBMP-8.4–100% for IBMP-8.1 and IBMP-8.2. Accuracy values ranged from 99.4 to 99.98%. The pretest probability for the molecules was 0.42, whereas the positive posttest probability ranged from 95.24 to 99.95% and the negative posttest probability ranged from 0.00001 to 0.0006% for all antigens. The higher odds ratio diagnosis was found for IBMP-8.4, which has been shown to be a safe single antigen for serological screening of CD in blood samples. The use of chimeric IBMP antigens is an alternative to reduce the number of bags discarded due to false-positive results. These molecules have high diagnostic performance and were shown to be suitable for use in screening CD in blood banks, isolated (IBMP-8.4) or in combination; and their use in blood banks could significantly reduce unnecessary disposal of blood bags or the risk of T. cruzi transmission.
In Brazil, the notification of congenital (CS) and syphilis in pregnant women (SiP) is compulsory. Notification data provided by the Ministry of Health in combination with the mapping of vulnerable geographic areas is essential to forecasting possible outbreaks and more effectively combating infection through monitoring. We aim to evaluate the spatiotemporal distribution and epidemiological aspects of reported cases of CS and SiP in Brazil. A retrospective ecological study was carried out using secondary surveillance data obtained from the Brazilian National Notifiable Diseases Information System (SINAN) database, considering all reported cases of CS and SiP between 2001 to 2017. Epidemiological characteristics and time trends were analyzed using joinpoint regression models and spatial distribution, considering microregions or states/macroregions as units of analysis. A total of 188,630 (359/100,000 birth lives) CS and 235,895 of SiP (6.3/100,000 inhabitants) were reported during the period studied. In general, the epidemiologic profile of Brazil indicates most reported CS cases occurred in "mixed-race" newborns who were diagnosed within seven days of birth and whose mothers had received prenatal care, but the epidemiologic profile varies by Brazilian macroregion. Regarding SiP, most cases were among women who self-reported ‘mixed-race’, were aged 20–39 years, had up to eight years of formal education and were diagnosed with primary or latent syphilis. Approximately 549 (98.4%) and 558 (100%) microregions reported at least one case of CS and SiP, respectively. From 2012 to 2016, CS cases increased significantly in almost all Brazilian states, most notably in the South, Southeast, and Central-West macroregions, from 2001–2017 and the relative risk (RR) of SiP increased around 400% (RR: 1,00 to 445,50). Considering the epidemiological scenario of the infection in Brazil, it is necessary to enhance preventive, control and eradication measures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.