The extended range of vision IOL provides better distance, intermediate, and near visual acuity than the aspheric monofocal IOL, while maintaining the same level of visual quality. [J Refract Surg. 2016;32(7):436-442.].
The extended-range-of-vision IOL and +2.5 D multifocal IOL provided significantly better intermediate visual restoration after cataract surgery than the monofocal IOL and +3.0 D multifocal IOL, with significantly better quality of vision with the extended-range-of-vision IOL.
This study demonstrated that the smaller diameter XEN 45 gel implant is statistically effective in reducing IOP and medications in glaucoma patients with a low rate of complications.
ABSTRACT.Purpose: To examine the circadian intraocular pressure (IOP) patterns in healthy subjects, in primary open angle and normal tension glaucoma (POAG; NTG) using a contact lens sensor (CLS; Sensimed Triggerfish, Lausanne, Switzerland). Methods: This was an observational, nonrandomized study. Ten healthy subjects (Group 1, 10 eyes) and 20 glaucomatous patients [20 eyes, 10 with POAG (Group 2) and 10 with NTG (Group 3)] were enrolled. All patients were controlled with prostaglandin analogues. The 24-hr IOP pattern was the main outcome. The morning (6AM-11AM), afternoon/evening (noon-11PM) and night (midnight-5AM) subperiod patterns, peaks and prolonged peaks (>1 hr) were secondary outcomes. Results: Mean 24-hr IOP pattern showed a nocturnal acrophase in all groups. Patterns were significantly different among groups (p = 0.02), with highest nocturnal IOP values in POAG. Prolonged peaks were more common in patients with glaucoma (70%) than in healthy subjects (33.3%) (p < 0.001). Significant differences were found for Groups 2 and 3 in the morning versus afternoon/evening (p = 0.019 and p = 0.035, Bonferroni correction), morning versus night (p = 0.005 and p < 0.0001) and afternoon/evening versus night periods comparisons (p < 0.0001 for both groups). In Group 1, patterns significantly differed in the morning versus night and afternoon/evening versus night period comparisons (p < 0.0001). Conclusions: Continuous 24-hr IOP monitoring with the CLS revealed a nocturnal acrophase in healthy subjects and, more markedly, in glaucoma. Because the diurnal IOP profile seems not to predict the nocturnal rhythm, the circadian IOP pattern should be evaluated in clinical practice. These findings may be worthwhile for the management of glaucoma.
The femtosecond laser procedure was safe, efficient, and less damaging, as evidenced by lower central endothelial cell loss, lower increase of corneal thickness at the incision site, and better tunnel morphology compared to the manual technique.
The recent development of new devices that are significantly less invasive, collectively termed minimally invasive glaucoma surgery, offers new perspective of intraocular pressure reduction with less risk, short operating times, and rapid recovery. The aim of this work is to provide a panoramic review of the currently published clinical data to assess the potential role of XEN gel stent (Allergan PLC, Irvine, CA, USA) in the management of glaucoma, which is the only filtering minimally invasive glaucoma surgery device that allows the subconjunctival filtration. The ab interno placement of the XEN gel stent offers an alternative for lowering intraocular pressure in refractory glaucoma as a final step, and in patients intolerant to medical therapy as an early surgical approach with minimum conjunctival tissue disruption, restricted flow to avoid hypotony, and long-term safety.
Purpose To compare the functional and clinical outcomes of the iris-claw intraocular lens (IOL) placed on the anterior versus posterior surface of the iris. Patients and Methods A multicenter, retrospective study. Data on eyes that underwent anterior or retropupillary iris-claw IOL implantation because of inadequate capsular support secondary to complicated cataract surgery, trauma, and dislocated/opacified IOLs since January 2015 were analyzed. For study inclusion, evaluation results had to be available in the medical records both preoperatively and at 1 and 12 months after implantation. The following parameters were compared between the groups: best-corrected distance visual acuity (BCDVA), spherical and cylindrical refractive error, endothelial cell density (ECD), central macular thickness (CMT), and percentage and type of postoperative complications. Results In total, 60 eyes of 60 patients aged 73 ± 13 years were included: 28 eyes (47%) involved anterior, and 32 eyes (53%) retropupillary, iris-claw IOL fixations. Preoperatively, the groups were similar in all parameters except for a significantly higher proportion of retropupillary fixations in patients who had previously experienced a closed-globe trauma (p=0.03). The groups showed comparable improvements in BCDVA after surgery (final BCDVA: 0.34 ± 0.45 vs. 0.37 ± 0.50 logMAR in the anterior and retropupillary placement groups, respectively). During follow-up, no group difference was observed in refractive error or CMT. Both groups experienced similarly marked ECD loss and showed similar incidence of postoperative complications, with cystoid macular edema being the most common complication. Multivariable linear regression showed that BCDVA at 1 month was the best predictor of the final BCDVA. Conclusions Anterior chamber and posterior chamber iris-claw IOL fixations proved equally effective and safe for aphakic correction in eyes with inadequate capsular support.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.