Host response biomarkers can accurately distinguish between influenza and bacterial infection. However, published biomarkers require the measurement of many genes, thereby making it difficult to implement them in clinical practice. This study aims to identify a single-gene biomarker with a high diagnostic accuracy equivalent to multi-gene biomarkers.In this study, we combined an integrated genomic analysis of 1071 individuals with experiments using well-established infection models.We identified a single-gene biomarker,, which had a high prediction accuracy (91%) equivalent to that obtained by multi-gene biomarkers. studies showed that was upregulated by TLR7 in plasmacytoid dendritic cells, antigen-presenting cells that responded to influenza virus rather than bacteria. studies confirmed that was expressed in influenza patients but not in bacterial infection, as demonstrated in multiple patient cohorts (n=521). In a large prospective study (n=439) of patients presented with undifferentiated respiratory illness (aetiologies included viral, bacterial and non-infectious conditions), displayed 88% diagnostic accuracy (AUC) and 90% specificity in discriminating between influenza and bacterial infections. represents a significant step forward in overcoming a translational barrier in applying genomic assay in clinical setting; its implementation may improve the diagnosis and management of respiratory infection.
Erythropoietin (EPO) is a 30.4 kDa glycoprotein produced by the kidney, and is mostly well-known for its physiological function in regulating red blood cell production in the bone marrow. Accumulating evidence, however, suggests that EPO has additional organ protective effects, which may be useful in the prevention or treatment of acute kidney injury. These protective mechanisms are multifactorial in nature and include inhibition of apoptotic cell death, stimulation of cellular regeneration, inhibition of deleterious pathways, and promotion of recovery.In this article, we review the physiology of EPO, assess previous work that supports the role of EPO as a general tissue protective agent, and explain the mechanisms by which it may achieve this tissue protective effect. We then focus on experimental and clinical data that suggest that EPO has a kidney protective effect.
There is limited information on the incidence of acute kidney injury (AKI) in patients with traumatic brain injury (TBI) although AKI may contribute to morbidity and mortality. We investigated the incidence of AKI in patients with moderate and severe TBI and the association of AKI with risk factors and outcomes in these patients. We studied all TBI patients over 16 years of age admitted to the two designated trauma hospitals in the state of Victoria, Australia from 1 January to 31 December 2008. Patients were included if they had head trauma and presented with a Glasgow coma scale (GCS) <13. Prospectively collected data from the hospital trauma registries, ICUs, and pathology databases were analyzed retrospectively. Risk injury failure loss end (RIFLE) criteria were used to categorize renal function. The incidence of AKI was 9.2% (19/207). Patients who developed AKI were older, had higher severity of illness scores, and a lower GCS. Overall 42.1% of these patients died in hospital compared with 18.1% in patients without AKI. In univariable linear regression analysis, age, severity of illness, and admitting hospital were associated with AKI. After multivariable logistic regression, the occurrence of AKI was associated with age (p < 0.001) and higher APACHE III scores (p = 0.016). AKI is relatively common even in patients with TBI. Its association with age and APACHE III scores helps identify patients at higher risk of AKI.
This work describes the development of a quality control protocol, which can be implemented to assess the accuracy, precision and reproducibility of the apparent diffusion coefficient (ADC) measurement on a clinical magnetic resonance imaging (MRI) system. The precision and accuracy of the ADC measurement are analysed with regard to MRI system noise, signal reproducibility and differences between nominal and effective b values. Two aqueous test-solutions of CuSO4 and sucrose are prepared for the quality control protocol. ADC measurement with the CuSO4 solution is more sensitive to differences between nominal and effective b values, on account of the solution's high ADC. ADC measurement with the sucrose solution is more sensitive to signal reproducibility due to the solution's low baseline signal intensity. The ADC of the test-solutions is measured on an MRI system at our centre with a sequence used for clinical studies using diffusion imaging. Two parameters, Q and R, are defined for the analysis of the quality control ADC values. The Q parameter is the ratio of the standard deviation of the quality control mean ADC values over time to the optimal standard deviation, as derived from the effect of thermal noise on the ADC measurement uncertainty. Analysis with the Q parameter indicates that signal reproducibility errors contribute to ADC variations on our MRI system when imaging with high b values (b > 500 mm s(-2)), whereas differences between nominal and effective b values have a greater impact on the ADC measurement when imaging with low b values (b < 500 mm s(-2)). The R parameter is defined as the ratio of the directional variation of the ADC quality control values to the uncertainty of the ADC measurement. Analysis with the R parameter shows that the effect of directional variation of the ADC measurement on our MRI system is more pronounced when imaging with low b values. The quality control protocol identified a systematic error, which introduced a small system-induced anisotropy in the ADC measurement. This error is currently taken into account in the analysis of clinical studies employing the diffusion imaging sequence used in this quality control protocol.
This systematic review of multidisciplinary literature synthesizes evidence of the prevalence and patterns of sensory processing disorder (SPD) in children ages birth-3 yr born preterm. Forty-five articles including physiological, behavioral, temperament, and SPD research met the inclusion criteria and provided 295 findings related to SPD-130 (44%) positive (evidence of SPD) and 165 (56%) negative (no evidence of SPD). The majority of findings related to sensory modulation disorder (SMD; 43% positive). The most prevalent subcategory of SMD was sensory overresponsivity (82% of findings positive). Evidence of sensory underresponsivity and sensory-seeking SMD, sensory discrimination disorder, and sensory-based motor disorder was limited. This study supports the education of neonatologists, pediatricians, and caregivers about the symptoms and potential consequences of SPD and helps justify the need for follow-up screening for SPD in children ages birth-3 yr born preterm. Research using measures based on sensory processing theory is needed.
60 patients underwent emergency surgical repair of the aortic arch (mean age years, men) for AAD. All operations were performed under hypothermic circulatory arrest with antegrade selective cerebral perfusion. Preoperatively, 20% n=12 patients were in cardiogenic shock and n=10 patients showed malperfusion (3 cerebral, 2 limbs, 3 renal, 2 Gut). The average duration before surgical intervention was 12Â AE 3.5 hours Results: Circulatory arrest time was 25Â AE 15 mins and that of myocardial ischaemia was 110Â AE24 mins. Total aortic arch replacement was done in 44 patients and hemiarch aortic replacement in 16 patients Dual cannulation reduced cooling and warming time by 30mins compared to single cannulation techniques, flow was distributed 45%Â AE5.5 axillary, 55%Â AE4.5 femoral and line pressure was 40%Â AE4.5% less than single cannula. The hospital mortality rate was 17% (n=10); the fatal cases were among those who were in shock preoperatively n=5 2 presented with coronary malperfusion. The perioperative stroke rate was n=2, one presented with preoperative coma. The hospital mortality rate of the patients with preoperative malperfusion was 30% n=3/10 1 cerebral 1 coronary, 1 gut. Our approach for AAD was associated with a low mortality even in patients with malperfusion at presentation.Conclusions: Our results suggest that dual axillary and femoral artery cannulation with side graft was successful in 100% of patients, reduces the drawbacks of single site cannulation, provides flexibility to adapt to changing circumstances, perfuses both lumens until repair is established, and may be the optimal technique for reducing perfusion-related morbidity and adverse outcome in operations for acute dissection, atherosclerotic, and degenerative aneurysmal disease. It deserves serious consideration in all patients.http://dx.
In patients with TBI, intravenous fluids are integral to management; they may be both a source of harm and a potential therapy to limit secondary brain injury. They should be prescribed in accordance with other pharmaceutical or therapeutic interventions. Refined usage may improve patient outcomes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.