BackgroundGold NanoParticle (GNP) dose‐enhanced radiation therapy (GNPT) requires consideration of physics across macro‐ to microscopic length scales, however, this presents computational challenges that have limited previous investigations.PurposeTo develop and apply multiscale Monte Carlo (MC) simulations to assess variations in nucleus and cytoplasm dose enhancement factors (n,cDEFs) over tumor‐scale volumes.MethodsThe intrinsic variation of n,cDEFs (due to fluctuations in local gold concentration and cell/nucleus size variation) are estimated via MC modeling of varied cellular GNP uptake and cell/nucleus sizes. Then, the Heterogeneous MultiScale (HetMS) model is implemented in MC simulations by combining detailed models of populations of cells containing GNPs within simplified macroscopic tissue models to evaluate n,cDEFs. Simulations of tumors with spatially uniform gold concentrations (5, 10, or 20 mgAu/gtissue) and spatially varying gold concentrations eluted from a point are performed to determine n,cDEFs as a function of distance from the source for 10 to 370 keV photons. All simulations are performed for three different intracellular GNP configurations: GNPs distributed on the surface of the nucleus (perinuclear) and GNPs packed into one or four endosome(s).ResultsIntrinsic variations in n,cDEFs can be substantial, for example, if GNP uptake and cell/nucleus radii are varied by 20%, variations of up to 52% in nDEF and 25% in cDEF are observed compared to the nominal values for uniform cell/nucleus size and GNP concentration. In HetMS models of macroscopic tumors, subunity n,cDEFs (i.e., dose decreases) can occur for low energies and high gold concentrations due to attenuation of primary photons through the gold‐filled volumes, for example, n,cDEF<1 is observed 3 mm from a 20 keV source for the four endosome configuration. In HetMS simulations of tumors with spatially uniform gold concentrations, n,cDEFs decrease with depth into the tumor as photons are attenuated, with relative differences between GNP models remaining approximately constant with depth in the tumor. Similar initial n,cDEF decreases with radius are seen in the tumors with spatially varying gold concentrations, but the n,cDEFs for all of the GNP configurations converge to a single value for each energy as gold concentration reaches zero.ConclusionsThe HetMS framework has been implemented for multiscale MC simulations of GNPT to compute n,cDEFs over tumor‐scale volumes, with results demonstrating that cellular doses are highly sensitive to cell/nucleus size, GNP intracellular distribution, gold concentration, and cell position in tumor. This work demonstrates the importance of proper choice of computational model when simulating GNPT scenarios and the need to account for intrinsic variations in n,cDEFs due to variations in cell/nucleus size and gold concentration.
Background: The introduction of Gold NanoParticles (GNPs) in radiotherapy treatments necessitates considerations such as GNP size, location, and quantity, as well as patient geometry and beam quality. Physics considerations span length scales across many orders of magnitude (nanometer-to-centimeter), presenting challenges that often limit the scope of dosimetric studies to either micro-or macroscopic scales. Purpose: To investigate GNP dose-enhanced radiation Therapy (GNPT) through Monte Carlo (MC) simulations that bridge micro-to-macroscopic scales. The work is presented in two parts, with Part I (this work) investigating accurate and efficient MC modeling at the single cell level to calculate nucleus and cytoplasm Dose Enhancement Factors (n,cDEFs), considering a broad parameter space including GNP concentration, GNP intracellular distribution, cell size, and incident photon energy. Part II then evaluates cell dose enhancement factors across macroscopic (tumor) length scales. Methods: Different methods of modeling gold within cells are compared, from a contiguous volume of either pure gold or gold-tissue mixture to discrete GNPs in a hexagonal close-packed lattice. MC simulations with EGSnrc are performed to calculate n,cDEF for a cell with radius r cell = 7.35 µm and nucleus r nuc = 5 µm considering 10 to 370 keV incident photons, gold concentrations from 4 to 24 mg Au /g tissue , and three different GNP configurations within the cell: GNPs distributed around the surface of the nucleus (perinuclear) or GNPs packed into one (or four) endosome(s). Select simulations are extended to cells with different cell (and nucleus) sizes: 5 µm (2, 3, and 4 µm), 7.35 µm (4 and 6 µm), and 10 µm (7, 8, and 9 µm). Results: n,cDEFs are sensitive to the method of modeling gold in the cell, with differences of up to 17% observed; the hexagonal lattice of GNPs is chosen (as the most realistic model) for all subsequent simulations. Across cell/nucleus radii, source energies, and gold concentrations, both nDEF and cDEF are highest for GNPs in the perinuclear configuration, compared with GNPs in one (or four) endosome(s). Across all simulations of the (r cell , r nuc ) = (7.35, 5) µm cell, nDEFs and cDEFs range from unity to 6.83 and 3.87, respectively. Including different cell sizes, nDEFs and cDEFs as
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.