Non-healing chronic wounds present a major biological, psychological, social, and financial burden on both individual patients and the broader health system. Pathologically extensive inflammation plays a major role in the disruption of the normal healing cascade. The causes of chronic wounds (venous, arterial, pressure, and diabetic ulcers) can be examined through a juxtaposition of normal healing and the rogue inflammatory response created by the common components within chronic wounds (ageing, hypoxia, ischaemia-reperfusion injury, and bacterial colonisation). Wound bed care through debridement, dressings, and antibiotics currently form the basic mode of treatment. Despite recent setbacks, pharmaceutical adjuncts form an interesting area of research.
Non-technical summary Relaxed skeletal muscles behave like springs that resist joint motion.There have been few in vivo studies of the spring-like properties of relaxed muscles. In this study, ultrasound was used to image human calf muscles while muscle length was changed by rotating the ankle of relaxed subjects. The muscles of some subjects buckled at short lengths. At short lengths most muscle fascicles (bundles of muscle cells) are slack. As the muscle is lengthened the slack is progressively taken up, first in some fascicles then in others. The increase in muscle length is due partly to increases in the length of muscle fascicles but most of the increase in muscle length occurs in the tendons.Abstract Ultrasound imaging was used to measure the length of muscle fascicles in human gastrocnemius muscles while the muscle was passively lengthened and shortened by moving the ankle. In some subjects the muscle belly 'buckled' at short lengths. When the gastrocnemius muscle-tendon unit was passively lengthened from its shortest in vivo length by dorsiflexing the ankle, increases in muscle-tendon length were not initially accompanied by increases in muscle fascicle lengths (fascicle length remained constant), indicating muscle fascicles were slack at short muscle-tendon lengths. The muscle-tendon length at which slack is taken up differs among fascicles: some fascicles begin to lengthen at very short muscle-tendon lengths whereas other fascicles remain slack over a large range of muscle-tendon lengths. This suggests muscle fascicles are progressively 'recruited' and contribute sequentially to muscle-tendon stiffness during passive lengthening of the muscle-tendon unit. Even above their slack lengths muscle fascicles contribute only a small part (<∼30%) of the total change in muscle-tendon length. The contribution of muscle fascicles to muscle-tendon length increases with muscle length. The novelty of this work is that it reveals a previously unrecognised phenomenon (buckling at short lengths), posits a new mechanism of passive mechanical properties of muscle (recruitment of muscle fascicles), and confirms with high-resolution measurements that the passive compliance of human gastrocnemius muscle-tendon units is due largely to the tendon. It would be interesting to investigate if adaptations of passive properties of muscles are associated with changes in the distribution of muscle lengths at which fascicles fall slack.
BackgroundMost data on the architecture of the human soleus muscle have been obtained from cadaveric dissection or two-dimensional ultrasound imaging. We present the first comprehensive, quantitative study on the three-dimensional anatomy of the human soleus muscle in vivo using diffusion tensor imaging (DTI) techniques.MethodsWe report three-dimensional fascicle lengths, pennation angles, fascicle curvatures, physiological cross-sectional areas and volumes in four compartments of the soleus at ankle joint angles of 69 ± 12° (plantarflexion, short muscle length; average ± SD across subjects) and 108 ± 7° (dorsiflexion, long muscle length) of six healthy young adults. Microdissection and three-dimensional digitisation on two cadaveric muscles corroborated the compartmentalised structure of the soleus, and confirmed the validity of DTI-based muscle fascicle reconstructions.ResultsThe posterior compartments of the soleus comprised 80 ± 5% of the total muscle volume (356 ± 58 cm3). At the short muscle length, the average fascicle length, pennation angle and curvature was 37 ± 8 mm, 31 ± 3° and 17 ± 4 /m, respectively. We did not find differences in fascicle lengths between compartments. However, pennation angles were on average 12° larger (p < 0.01) in the posterior compartments than in the anterior compartments. For every centimetre that the muscle-tendon unit lengthened, fascicle lengths increased by 3.7 ± 0.8 mm, pennation angles decreased by −3.2 ± 0.9° and curvatures decreased by −2.7 ± 0.8 /m. Fascicles in the posterior compartments rotated almost twice as much as in the anterior compartments during passive lengthening.DiscussionThe homogeneity in fascicle lengths and inhomogeneity in pennation angles of the soleus may indicate a functionally different role for the anterior and posterior compartments. The data and techniques presented here demonstrate how DTI can be used to obtain detailed, quantitative measurements of the anatomy of complex skeletal muscles in living humans.
Snus is an oral smokeless tobacco product which is usually placed behind the upper lip, either in a loose form or in portioned sachets, and is primarily used in Sweden and Norway. The purpose of this review is to examine the reported effects of snus use in relation to specified health effects, namely lung cancer, cardiovascular disease, pancreatic cancer, diabetes, oral cancer and non-neoplastic oral disease. The review also examines the harm reduction potential of snus as an alternative to cigarettes by comparing the prevalence of snus use and cigarette smoking, and the reported incidence of tobacco-related diseases across European Union countries. The scientific literature generally indicates that the use of snus is not a significant risk factor for developing lung cancer, cardiovascular disease, pancreatic cancer or oral cancer. Studies investigating snus use and diabetes have reported that high consumption of snus (estimated as being four or more cans per week) may be associated with a higher risk of developing diabetes or components of metabolic syndrome; however, overall results are not conclusive. Snus use is associated with the presence of non-neoplastic oral mucosal lesions which are reported to heal rapidly once use has stopped. The most recent Eurobarometer data from 2017 reported that Sweden had the lowest prevalence of daily cigarette use in the European Union at 5% whilst daily “oral tobacco” use was reported to be 20%. European data published by the World Health Organisation in 2018 indicated that Sweden had the lowest rate of tobacco-related mortality and the lowest incidence of male lung cancer. Overall, prevalence statistics and epidemiological data indicate that the use of snus confers a significant harm reduction benefit which is reflected in the comparatively low levels of tobacco-related disease in Sweden when compared with the rest of Europe. The available scientific data, including long-term population studies conducted by independent bodies, demonstrates that the health risks associated with snus are considerably lower than those associated with cigarette smoking.
Post-traumatic osteoarthritis (PTOA) is defined by its development after joint injury. Factors contributing to the risk of PTOA occurring, the rate of progression, and degree of associated disability in any individual, remain incompletely understood. What constitutes an "OA-inducing injury" is not defined. In line with advances in the traumatic brain injury field, we propose the scope of PTOA-inducing injuries be expanded to include not only those causing immediate structural damage and instability (Type I), but also those without initial instability/damage from moderate (Type II) or minor (Type III) loading severity. A review of the literature revealed this full spectrum of potential PTOA subtypes can be modeled in mice, with 27 Type I, 6 Type II, and 4 Type III models identified. Despite limitations due to cartilage anatomy, joint size, and bio-fluid availability, mice offer advantages as preclinical models to study PTOA, particularly genetically modified strains. Histopathology was the most common disease outcome, cartilage more frequently studied than bone or synovium, and meniscus and ligaments rarely evaluated. Other methods used to examine PTOA included gene expression, protein analysis, and imaging. Despite the major issues reported by patients being pain and biomechanical dysfunction, these were the least commonly measured outcomes in mouse models. Informative correlations of simultaneously measured disease outcomes in individual animals, was rarely done in any mouse PTOA model. This review has identified knowledge gaps that need to be addressed to increase understanding and improve prevention and management of PTOA. Preclinical mouse models play a critical role in these endeavors. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:424-439, 2017.
Muscle moment arms are used widely in biomechanical analyses. Often they are measured in 2D or at a series of static joint positions. In the present study we demonstrate a simple MRI method for measuring muscle moment arms dynamically in 3D from a single range-of-motion cycle. We demonstrate this method in the Achilles tendon for comparison with other methods, and validate the method using a custom apparatus. The method involves registration of high-resolution joint geometry from MRI scans of the stationary joint with low-resolution geometries from ultrafast MRI scans of the slowly moving joint. Tibio-talar helical axes and 3D Achilles tendon moment arms were calculated throughout passive rotation for 10 adult subjects, and compared with recently published data. A simple validation was conducted by comparing MRI measurements with direct physical measurements made on a phantom. The moment arms measured using our method and those of others were similar and there was good agreement between physical measurements (mean 41.0mm) and MRI measurements (mean 39.5mm) made on the phantom. This new method can accurately measure muscle moment arms from a single range-of-motion cycle without the need to control rotation rate or gate the scanning. Supplementary data includes custom software to assist implementation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.