The aim of this retrospective cohort study was to identify any difference in femoral offset as measured on pre-operative anteroposterior (AP) radiographs of the pelvis, AP radiographs of the hip and corresponding CT scans in a consecutive series of 100 patients with primary end-stage osteoarthritis of the hip (43 men and 57 women with a mean age of 61 years (45 to 74) and a mean body mass index of 28 kg/m(2) (20 to 45)). Patients were positioned according to a standardised protocol to achieve reproducible projection and all images were calibrated. Inter- and intra-observer reliability was evaluated and agreement between methods was assessed using Bland-Altman plots. In the entire cohort, the mean femoral offset was 39.0 mm (95% confidence interval (CI) 37.4 to 40.6) on radiographs of the pelvis, 44.0 mm (95% CI 42.4 to 45.6) on radiographs of the hip and 44.7 mm (95% CI 43.5 to 45.9) on CT scans. AP radiographs of the pelvis underestimated femoral offset by 13% when compared with CT (p < 0.001). No difference in mean femoral offset was seen between AP radiographs of the hip and CT (p = 0.191). Our results suggest that femoral offset is significantly underestimated on AP radiographs of the pelvis but can be reliably and accurately assessed on AP radiographs of the hip in patients with primary end-stage hip osteoarthritis. We, therefore, recommend that additional AP radiographs of the hip are obtained routinely for the pre-operative assessment of femoral offset when templating before total hip replacement.
Persistent pain is an important cause of patient dissatisfaction after unicompartmental knee replacement (UKR) and has been correlated with localised tibial strain. However, the factors that influence these strains are not well understood. To address this issue, we created finite element models to examine the effect on tibial strain of: (1) muscle forces (estimated using instrumented knee data) acting on attachment sites on the proximal tibia, (2) UKR implantation, (3) loading position, and (4) changes in gait pattern. Muscle forces acting on the tibia had no significant influence on strains within the periprosthetic region, but UKR implantation increased strain by 20%. Strain also significantly increased if the region of load application was moved >3 mm medially. The strain within the periprosthetic region was found to be dependent on gait pattern and was influenced by both medial and lateral loads, with the medial load having a greater effect (regression coefficients: medial=0.74, lateral=0.30). These findings suggest that tibial strain is increased after UKR and may be a cause of pain. It may be possible to reduce pain through modification of surgical factors or through altered gait patterns.
The occurrence of pseudotumours (soft tissue masses relating to the hip joint) following metal-on-metal hip resurfacing arthroplasty has been associated with higher than normal bearing wear and high serum metal ion levels although both these findings do not necessarily coexist. The purpose of this study was to examine patient activity patterns and their influence on acetabular component edge loading in a group of subjects with known serum metal ion levels. Fifteen subjects with metal-on-metal hip resurfacing arthroplasty (eight males and seven females) were recruited for motion analysis followed by computed tomography scans. They were divided into three groups based on their serum metal ion levels and the orientation of their acetabular component: well-positioned acetabular component with low metal ions, mal-positioned acetabular component with low metal ions and mal-positioned acetabular component with high ions. A combination of motion analysis, subject-specific modelling (AnyBody Modeling System, Aalborg, Denmark) and computed tomography measurements was used to calculate dynamically the contact patch-to-rim distance for each subject during gait and sit-to-stand. The contact-pitch-to-rim distance for the high ion group was significantly lower (p<0.001) than for the two low ion groups (well-positioned and mal-positioned) during the stance phase of gait (0%-60%) and loading phase of sit-to-stand (20%-80%). The results of this study, in particular, the significant difference between the two mal-positioned groups, suggest that wear of metal-on-metal hip resurfacing arthroplasty is not only affected by acetabular cup orientation but also influenced by individual patient activity patterns.
The successful short-term results of the ACLD group suggest ACL deficiency may not always be a contraindication to Oxford UKA as previously thought. Until long-term data is available, however, we maintain our recommendation that ACLD be considered a contraindication.
The present findings of native acetabular and femoral orientation in patients with primary hip osteoarthritis support intraoperative component positioning for total hip arthroplasty.
Since the Oxford knee was first used unicompartmentally in 1982, a small number of bearings have fractured. Of 14 retrieved bearings, we examined ten samples with known durations in situ (four Phase 1, four Phase 2 and two Phase 3). Evidence of impingement and associated abnormally high wear (> 0.05 mm per year) as well as oxidation was observed in all bearings. In four samples the fracture was associated with the posterior radio-opaque wire. Fracture surfaces indicated fatigue failure, and scanning electron microscopy suggested that the crack initiated in the thinnest region. The estimated incidence of fracture was 3.20% for Phase 1, 0.74% for Phase 2, 0.35% for Phase 3, and 0% for Phase 3 without the posterior marker wire. The important aetiological factors for bearing fracture are impingement leading to high wear, oxidation, and the posterior marker wire. With improved surgical technique, impingement and high wear should be prevented and modern polyethylene may reduce the oxidation risk. A posterior marker wire is no longer used in the polyethylene meniscus. Therefore, the rate of fracture, which is now very low, should be reduced to a negligible level.
Knee replacement is one of the commonest surgical procedures performed in older adults, and its incidence is increasing rapidly. It is the only curative procedure for knee osteoarthritis, and it has excellent outcomes overall in terms of reoperation, functional outcomes and cost-effectiveness. However, a significant proportion of patients are dissatisfied after knee replacement surgery and there is a growing body of research into predictors of poor outcome and dissatisfaction.In this review, we discuss the place of total knee replacement (TKR) in the management of osteoarthritis, together with operative and non-operative alternatives to TKR. We discuss the different ways in which outcome can be measured, and the influence of patient and surgical factors on the success or failure of knee replacement surgery.
This study explores the extent of bearing overhang following mobile bearing Oxford unicompartmental knee replacement (OUKR) (Oxford Phase 3, Zimmer Biomet). The Oxford components are designed to be fully congruent, however knee movements involve femoral rollback, which may result in bearing overhang at the posterior margin of the tibial implant, with potential implications for; pain, wear, and dislocation. Movement is known to be greater, and therefore posterior overhang more likely to occur, with; lateral compared to medial implants, anterior cruciate ligament (ACL) deficiency (ACLD) compared to ACL intact (ALCI), and at extremes of movement. Twenty-four medial, and 20 domed lateral, OUKRs underwent sagittal plane knee fluoroscopy during step-up and forward lunge exercises. The bearing position was inferred from the relative position of the femoral and tibial components. On the basis of the individual component sizes and geometry the extent the posterior part of the bearing which overhung the posterior part of the tibial component was calculated. There was no significant posterior overhang in knees with medial implants. Knees with lateral domed implants exhibited overhang at flexion angles beyond 60°, the magnitude of which increased with increasing flexion angle, reaching a maximum of 50% of the bearing length at 140°(range 0-140°). This demonstrates a clear difference between the kinematics, and prevalence and extent of posterior bearing overhang between medial and lateral OUKRs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.