The results of a new method for arthroscopic all-inside meniscus repair using a biodegradable cannulated screw (Clearfix meniscal screw) were assessed in a medium-term follow-up prospective study. The Clearfix meniscal screw system consists of delivery cannulae, screw driver, and screw implants. After tear debridement, a screw is located on the driver and passed through the cannula to the insertion site, holding the two sides of the tear together under linear compression. Forty-eight patients (48 repairs) with a mean age of 32.7 years were included in the study. Ligament stabilizing procedures were done in 39 patients (81%) who had anterior cruciate ligament deficient knees. Only longitudinal lesions in the red/red or red/white zone were repaired. Follow-up averaged 19 months, with a range from 12 to 48 months. Patients were evaluated using clinical examination, the "Orthopaedische Arbeitsgemeinschaft Knie (OAK)" knee evaluation scheme and magnetic resonance imaging (MRI). Criteria for clinical success included absence of joint-line tenderness, absence of swelling and a negative McMurray test. Postoperatively, there were no complications directly associated with the device. Twelve of 48 repaired menisci (25%) were considered failures according to the above-mentioned criteria. According to the OAK knee evaluation scheme, 38 patients (79%) had an excellent or good result. MRI, however, showed persisting grade III or IV lesions in 35 patients (73%). Analysis showed that age, length of tear, and simultaneous anterior cruciate ligament reconstruction did not affect the clinical outcome. In contrast, risk factors for failure of meniscus repair are chronicity of injury, location of tear more than 3 mm from the meniscosynovial junction and meniscus side (medial).
A patient with a unique combination of ipsilateral midradial shaft (AO/OTA 22-A2), radial head (21-A2), and medial epicondyle (13-A1) fractures, without a recorded elbow dislocation or distal radioulnar joint disruption, is presented. The injury was treated surgically with a dorsal approach to the forearm and a lateral approach to the elbow through a single dorsolateral skin incision. The radial shaft fracture was stabilized using a 3.5-mm limited contact, dynamic compression plate; the radial head, using a 1.2-mm Luhr plate; and the medial epicondyle, using a partially threaded cancellous screw through a limited medial approach. The shaft fracture consolidated by 10 weeks, whereas radiographic consolidation of the radial head fracture was seen at 7 months. At the 15-month follow-up, the patient had achieved an excellent functional result. Awareness of the possibility of double injuries even in yet-unrecognized patterns is warranted when evaluating forearm and elbow trauma.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.