To cite this article: Mor®ni M, Cinotti S, Bellatreccia A, Paladino E, Gringeri A, Mannucci PM and the ReFacto-AICE Study Group. A multicenter pharmacokinetic study of the B-domain deleted recombinant factor VIII concentrate using different assays and standards. J Thromb Haemost 2003; 1: 2283±9.See also Lollar P. The factor VIII assay problem neither rhyme nor reason. This issue, pp. 2275±9.Summary. When the one-stage clotting assay is used in comparison with the chromogenic and immunological assays, plasma levels of factor (F)VIII are underestimated by 40±50% after infusion of B-domain deleted recombinant FVIII (BDD-rFVIII) in patients with hemophilia. A possible way to counteract the underestimation of FVIII levels by the one-stage assay is the adoption of a recombinant FVIII reference standard instead of a plasma standard. To evaluate the usefulness of such a standard [ReFacto 1 Laboratory Standard (RLS)], the pharmacokinetic parameters of a single dose of BDD-rFVIII (25 U kg À1 ) were evaluated in a multicenter study carried out in 18 patients with severe hemophilia A. The very low in vivo recovery, obtained with the combination of the one-stage assay and plasma reference standard, was increased up to the values obtained by the chromogenic assay when the results were expressed in terms of RLS. When the plasma standard was used, the one-stage/ chromogenic ratio was 0.82 AE 0.12 for FVIII levels above 25 U dL À1 and 1.42 AE 0.99 for FVIII levels below 25 U dL À1 . Using the RLS, the one-stage/chromogenic ratio increased to 1.01 AE 0.19 at FVIII levels above 25 U dL À1 , as a consequence of a complete overlap of the two decays; however, at FVIII levels below 25 U dL À1 , the one-stage/chromogenic ratio was still 1.6 AE 0.85. After the twelfth hour, FVIII concentrations obtained by chromogenic assay were always lower than those resulting from the one-stage clotting assay, independently of the standard used. Results obtained by chromogenic assay were not affected by the type of standard used. Compared with those obtained by the one-stage assay, higher values of clearance, lower volume of distribution area and shorter plasma half-life or mean residence time were obtained by chromogenic assay because of a shape change of the decay curve due to a shift to higher values in the ®rst part (time interval 0±12 h) and to lower values in the second part of the decay curve (time interval 12±48 h). As a consequence, the slope of the decay curve obtained by means of chromogenic assay was steeper. In conclusion, the more homogeneous results of in vivo recovery and pharmacokinetic analysis, due to the decrease of discrepancy between the two methods when RLS was used, make the cheaper and more widely used one-stage assay preferable to the more expensive chromogenic assay, on condition that the ReFacto speci®c standard has used.
For the creation of scaffolds in tissue engineering applications, it is essential to control the physical morphology of fibres and to choose compositions which do not disturb normal physiological function. Collagen, the most abundant protein in the human body, is a well-established biopolymer used in electrospinning compositions. It shows high in-vivo stability and is able to maintain a high biomechanical strength over time. In this study, the effects of collagen type I in polylactic acid-drug electrospun scaffolds for tissue engineering applications are examined. The samples produced were subsequently characterised using a range of techniques. Scanning electron microscopy analysis shows that the fibre morphologies varied across PLA-drug and PLA-collagen-drug samples - the addition of collagen caused a decrease in average fibre diameter by nearly half, and produced nanofibres. Atomic force microscopy imaging revealed collagen-banding patterns which show the successful integration of collagen with PLA. Solid-state characterisation suggested a chemical interaction between PLA and drug compounds, irgasan and levofloxacin, and the collagen increased the amorphous regions within the samples. Surface energy analysis of drug powders showed a higher dispersive surface energy of levofloxacin compared with irgasan, and contact angle goniometry showed an increase in hydrophobicity in PLA-collagen-drug samples. The antibacterial studies showed a high efficacy of resistance against the growth of both E. coli and S. Aureus, except with PLA-collagen-LEVO which showed a regrowth of bacteria after 48h. This can be attributed to the low drug release percentage incorporated into the nanofibre during the in vitro release study. However, the studies did show that collagen helped shift both drugs into sustained release behaviour. These ideal modifications to electrospun scaffolds may prove useful in further research regarding the acceptance of human tissue by inhibiting the potential for bacterial infection.
The chemical distribution and mechanical effects of drug compounds in loaded electrospun scaffolds, a potential material for hernia repair mesh, were characterised and the efficacy of the material was evaluated. Polycaprolactone electrospun fibres were loaded with either the antibacterial agent, irgasan, or the broad-spectrum antibiotic, levofloxacin. The samples were subsequently characterised by rheological studies, scanning electron microscopy (SEM), atomic force microscopy (AFM), contact angle goniometry (CAG), in vitro drug release studies, antibacterial studies and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Increased linear viscoelastic regions observed in the rheometry studies suggest that both irgasan and levofloxacin alter the internal structure of the native polymeric matrix. In vitro drug release studies from the loaded polymeric matrix showed significant differences in release rates for the two drug compounds under investigation. Irgasan showed sustained release, most likely driven by molecular diffusion through the scaffold. Conversely, levofloxacin exhibited a burst release profile indicative of phase separation at the edge of the fibres. Two scaffold types successfully inhibited bacterial growth when tested with strains of E. coli and S. aureus. Electrospinning drug-loaded polyester fibres is an alternative, feasible and effective method for fabricating non-woven fibrous meshes for controlled release in hernia repair.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.