Several vomiting episodes were reported in December 2007 by the management of a beach club in Calvià. The subsequent case investigation confirmed tuna fish consumption a few hours before onset of emesis in all cases. Microbiological analyses detected high bacterial levels in ready-to-eat fish samples, indicating inappropriate cooking procedures. More important, elevated levels of Bacillus cereus were present both in raw and cooked fish. No other pathogens were detected, indicating B. cereus as the etiological agent. To our knowledge, this is the first case of emetic disease by B. cereus likely to be associated with fish consumption.
The aim of this study was to survey the microbial levels of food contact surfaces in hotels. Microbiological levels of 4611 surfaces (chopping machines, kitchenware, knives, worktops, and cutting boards) from 280 different facilities in Spain were determined in a 3-year period. The contact-plate technique was used throughout the survey. Overall, the mean of the log of total aerobic count cm(-2) was 0.62, better than those reported for child-care and assisted living facilities. Significant differences were detected among different types of surfaces, time of sampling, season, and year. The majority (74%) of food contact surfaces sampled in Spanish hotels was within the recommended standard of <1.3 log CFU cm(-2), and differences depend on several factors. Our results set a representative picture of the actual situation in our resorts and establish the basis for the development of educational programs to improve food handlers' knowledge of foodborne diseases and their transmission via food contact surfaces.
Background
Legionnaires’ disease is a respiratory illness often associated with hotels and travel. Spain is a major tourist destination and one of the European countries with most cases of Legionnaires’ disease , both community- and travel-associated. However, the prevalence of Legionella in tourist facilities is unknown.
Aim
The present investigation aimed to survey the tourist facilities in the Balearic Islands, Spain, for Legionella prevalence.
Methods
We visited tourist facilities in the Balearic Islands in two different periods (2006–2010 and 2015–2018) and took water samples following national and international guidelines. Legionella was investigated by culture methods following international standards (ISO 11731:1998).
Results
We evaluated 13,472 samples from 465 facilities. Bacteria of the Legionella genus were detected in 65.4% of the surveyed facilities. Contamination of the facilities was significantly higher during the second decade (54.5 vs 78.6%). The most frequent colonisers were L. pneumophila serogroup 2–14. We detected the pathogen in 15.9% and 6.9% of hot and cold water distribution systems samples, respectively. The Legionella contamination rate in cold water systems samples was higher when free chlorine levels were < 0.2 mg/L and at > 25 °C temperatures, while in the hot water systems samples, the contamination rate was higher at < 50 °C. Of the samples from hot tubs, 10.9% were contaminated.
Conclusion
Legionella prevalence in hotels in the Balearic Islands was high but the contamination rates depended on the installations. Corrective measures are still needed to improve Legionella control.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.