The addition of traction radiographs appeared to affect surgeons' interobserver reliability in the evaluation of distal radial fractures. In addition, traction radiographs changed the rate of detection of intra-articular fragments requiring reduction and the perceived need for computed tomography. These data indicate that traction radiographs may provide some of the same information as computed tomographic scans at a lower cost and argue for additional research comparing computed tomographic scans and traction radiographs of the distal part of the radius.
Accurate reduction of ankle syndesmosis following injury is essential to minimize tibiofibular diastasis and optimize patient outcomes. Although several radiographic parameters have been described in the coronal plane to assist in reduction, tibiofibular diastasis following syndesmotic injury often occurs in the sagittal plane, with the fibula displacing posterior relative to the tibia. A technique using lateral fluoroscopic assessment of the uninjured contralateral ankle as a comparison and guide for accurate syndesmotic reduction is described.
In this series of patients, we demonstrate that a fascia iliaca block can reliably be utilized as the primary anesthetic for patients undergoing surgical fixation of intertrochanteric hip fractures, with an acceptable perioperative complication profile. Although concomitant sedation was provided with the block, this anesthesia strategy has the potential to reduce preoperative delays and minimize the overall burden of sedative and anesthetic medications in a geriatric population. These initial findings may serve as a basis for future, higher-quality prospective and comparative studies.
Background The coronavirus disease 19 (COVID-19) pandemic had a devastating effect on New York City in the spring of 2020. Several global reports suggested worse early outcomes among COVID-positive patients with hip fractures. However, there is limited data comparing baseline comorbidities among patients treated during the pandemic relative to those treated in non-pandemic conditions. Materials and Methods A multicenter retrospective cohort study was performed at two Level 1 Trauma centers and one orthopedic specialty hospital to assess demographics, comorbidities, and outcomes among 67 hip fracture patients treated (OTA/AO 31, 32.1) during the peak of the COVID-19 pandemic in New York City (March 20, 2020 to April 24, 2020), including 9 who were diagnosed with COVID-19. These patients were compared to a cohort of 76 hip fracture patients treated 1 year prior (March 20, 2019 to April 24, 2019). Baseline demographics, comorbidities, treatment characteristics, and respiratory symptomatology were evaluated. The primary outcome was inpatient mortality. Results Relative to patients treated in 2019, patients with hip fractures during the pandemic had worse Charlson Comorbidity Indices (median 5.0 vs 6.0, P = .03) and American Society of Anesthesiologists (ASA) scores (mean 2.4 vs 2.7, P = .04). Patients during the COVID-19 pandemic were more likely to have decreased ambulatory status ( P<.01) and a smoking history ( P = .04). Patients in 2020 had longer inpatient stays (median 5 vs 7 days, P = .01), and were more likely to be discharged home (61% vs 9%, P<.01). Inpatient mortality was significantly increased during the COVID-19 pandemic (12% vs 0%, P = .002). Conclusions Patients with hip fractures during the COVID-19 pandemic had worse comorbidity profiles and decreased functional status compared to patients treated the year prior. This information may be relevant in negotiations regarding reimbursement for cost of care of hip fracture patients with COVID-19, as these patients may require more expensive care.
Restoration of volar tilt is critical when performing open reduction and internal fixation of distal radius fractures. A reproducible technique is required to consistently achieve this goal. A simple technique using the locking plate and an electrocautery scratch pad as reduction tools can reliably generate volar tilt. This technique can be performed with minimal aid from surgical assistants.
Treatment of distal metaphyseal tibia fractures is often challenging. Newer tibial intramedullary (IM) nails are designed with a wider variety of distal locking options to offer greater stability in treating these fractures. In this study we attempted to determine the most biomechanically stable number and configuration of distal locking screws when treating distal metaphyseal tibia fractures with IM nails. A transverse osteotomy was created 4 cm from the tibial plafond in identical composite saw bones models (Type 43A fracture) as well as in human cadaveric bones. Each specimen was nailed using a tibial nail (Stryker T2). Distal locking was performed in one of the three configurations: (a) Group I: two screws in the medial lateral (ML) direction; (b) Group II: one ML screw and one screw in the anterior posterior (AP) direction; (c) Group 111: two ML screws and one AP screw. The specimens were then mounted onto a uniaxial material testing machine (Instron) and tested in compression. Our results showed that there was no statistical difference in the load-carrying capacity of Group 1 and Group II. This suggests that the treating surgeon can choose either of these two configurations depending on the wound or other considerations without sacrificing the compressive load-carrying capacity of the IM nail fixation. The load-carrying capacity of the Group III samples with these locking screws was higher than those of Group I & II, although this difference was not statistically significant. This work is being continued to compare the load-carrying capacity of the bone samples with the cortical thickness of bone. We also plan to examine the relationship between the load-carrying capacity of these surgical constructs with the bone mineral density of the metaphysis of these tibial specimens.
Treatment options for patients infected with multi-drug resistant gram-negative bacteria harboring metallo-beta-lactamases (MBLs) requires precision therapy. We present the case of a 20 year-old male with a right distal femoral peri-prosthetic abscess with presumed infected hardware and osteomyelitis in whom four multi-drug resistant gram negative bacteria were isolated. The rapid identification of an MBL producing organism, novel combination of therapy, and prompt infection prevention enforcement and education led to appropriate treatment of our patient as well as prevention of spread of organisms during and after hospitalization. This case illustrated successful management of multiple challenges faced by patients infected and/or harboring extensively resistant bacteria.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.