In comminuted patellar fractures, a combination of cerclage wiring and tension band fixation is said to provide good mechanical stability. This is a retrospective review of four patients treated with this method. All fractures described herein were classified as 45-C3 (based on Orthopaedic Trauma Association classification) and were fixed with a 1.25mm cerclage wire and tension band wire proximally looped through the quadriceps tendon and distally through the patellar ligament in a figure-of-eight configuration. The average follow-up period was 10 months. The Activity of Daily Living Scale (ADLS) of the Knee Outcome Survey was used to assess symptoms and functional capability of the knee. In all the cases, fracture union was achieved at an average of 11 weeks. The average ADLS score was good (92.5 %). Full range of knee motion was achieved by end of the third postoperative month. None of the patients had complications, such as infection and implant failure.
This retrospective radiographic analysis of 57 patients (62 knees) examined two possible factors involved in pin tract fractures of the femur due to navigated total knee arthroplasty (TKA): the angle of the tracker pin with respect to the lateral femoral cortex, and the distance between the tracker pin and the lateral joint line. Our findings demonstrate a relationship between postoperative pin tract induced stress fractures (3 patients), with pin tract angles exceeding 15°. Pin placement at a site more than 10cm from the lateral joint line, did not show any significant association with risk of fracture. These findings lead to enhanced understanding of the causative factors underlying pin track femoral fractures in TKAs.
This study was conducted to assess the optimum period for Kirschner wire fixation and cast immobilization for displaced lateral condylar fracture of the humerus in children. We retrospectively reviewed 12 patients with displaced lateral condyle humerus fracture, ranging in age from 3-9 y, with injuries that occurred between Jan 2005 and Dec 2006. All patients were treated with two Kirschner wire fixation and elbow immobilization. In all except 2 patients, the Kirschner wires were maintained for 3 to 4 weeks. Mean time for union was 3.78 weeks and mean humeroulnar arch motion at last review was 138.7 degrees. Only one patient had a 5 degree increased carrying angle in valgus as compared to the non-injured side, and 50% had prominent scars > 4mm. We conclude that fracture union can be expected within three to four weeks for most children after open reduction and fixation with 2 Kirschner wires.
In total knee arthroplasty, mechanical alignment guides have improved the accuracy of implant alignment, but errors are not uncommon. In the present study, an image-free computer-assisted navigation system was used to analyse the accuracy of an extramedullary (tibial) alignment system, which is based on predetermined, fixed anatomical landmarks. Comparisons were made between two surgeons, with different levels of competency in order to determine if experience affected the accuracy of extramedullary tibial jig placement, in either the coronal and sagittal planes or both planes. The results showed that the accuracy of the extramedullary tibial alignment system, in the coronal plane (in up to 80-87% of cases) was much better than for posterior slope, and sagittal plane. Surgeon experience was not a significant factor.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.