Background: Thyroid-stimulating antibodies (TSAb) are known to be responsible for hyperthyroidism in Graves' disease (GD). The conventional methods to measure TSAb depend on cell-based assays that require cumbersome procedures and a sterilized tissue culture technique. The aim of the present study was to develop a ready-to-use cell-based assay for measuring TSAb activity without requiring sterilized conditions. Methods: We developed a new assay kit using a frozen Chinese hamster ovary cell line expressing the thyroid-stimulating hormone receptor, cyclic adenosine monophosphate (cAMP)-gated calcium channel and aequorin, tentatively named the aequorin TSAb assay. Activated stimulatory G-protein-coupled adenylate cyclase increases intracellular cAMP, which then binds to the cyclic nucleotide-gated calcium channel. Activation of this channel allows Ca2+ to enter the cell, and the influx of Ca2+ can be measured with aequorin, which is quantified by a luminometer. Results can be obtained in only 4 h without sterilized conditions. TSAb activities were expressed by international units using the NIBSC 08/204 standard. Results: Positive results of aequorin TSAb were obtained in 197 of 199 (98.9%) of untreated patients with GD. Only 1 of 42 (2.3%) patients with painless thyroiditis had a weakly positive aequorin TSAb. All 45 patients with subacute thyroiditis and 185 normal subjects showed negative aequorin TSAb. As for chronic thyroiditis, all 52 euthyroid patients showed negative aequorin TSAb, but 8 of 50 (16.0%) hypothyroid patients had a positive reaction. However, these positive reactions were not induced by serum thyroid-stimulating hormone (TSH) and were thought to be induced by the stimulating activity of anti-TSH receptor immunoglobulins. Conventional porcine TSAb and Elecsys thyroid-stimulating hormone receptor antibodies were positive in 69.3 and 95.5% of GD, respectively. Conclusion: The aequorin TSAb assay was positive in 98.9% of GD and was more sensitive than the conventional assay. This assay can be conducted in only 4 h without sterilized conditions and is practically useful in general clinical laboratories.
Objective: Finding agranulocytosis (AG) at an early stage is important to improve outcome, but periodic granulocyte count monitoring is not generally recommended for patients with Graves' disease, because AG develops suddenly. Method: At the Kuma Hospital, Graves' patients under antithyroid drug (ATD) treatment in an outpatient clinic have a granulocyte count examination during each visit, and if it is <1,000/μl, a warning is immediately sent to the patient's physician. We evaluated the usefulness of this system. Results: We investigated 25 AG and 33 granulocytopenia (GP) cases over a recent 5-year period, excluding patients who developed AG or GP at another hospital and were referred to us for treatment. Among the 25 AG patients, 16 patients (64%; 9 asymptomatic and 7 very mild symptomatic cases) were discovered by the periodic granulocyte count examination at an outpatient clinic. The remaining 9 patients visited the Kuma Hospital or other hospitals because of infection symptoms. Most of the AG patients were given granulocyte colony-stimulating factor injections immediately and were admitted if a prompt increase in granulocytes could not be obtained. The final treatments for Graves' disease were 131I-radioisotope therapy (19 patients), thyroidectomy (2 patients), inorganic iodine (1 patient), or another ATD (1 patient). Among the 33 GP patients, 31 (94%), including 20 asymptomatic cases, were discovered during periodic granulocyte count monitoring. Most of them stopped ATD, and other treatments for Graves' disease were selected. Conclusion: Periodic monitoring of granulocyte counts is useful for identifying AG and GP patients with no or minimum infection symptoms.
The thyrotropin receptor (TSHR) plays critical roles in thyroid growth and function and in the pathogenesis of several thyroid diseases including Graves' hyperthyroidism and ophthalmopathy, non-autoimmune hyperthyroidism and thyroid cancer. Several low-molecular weight compounds (LMWCs) and anti-TSHR monoclonal antibodies (mAbs) with receptor antagonistic and inverse agonistic activities have been reported. The former binds to the pocket formed by the receptor transmembrane bundle, and the latter to the extracellular TSH binding site. Both are effective inhibitors of TSH/ thyroid stimulating antibody-stimulated cAMP and/or hyaluronic acid production in TSHR-expressing cells. Anti-insulin-like growth factor 1 inhibitors are also found to inhibit TSHR signaling. Each agent has advantages and disadvantages; for example, mAbs have a higher affinity and longer half-life but are more costly than LMWCs. At present, mAbs appear most promising, yet the development of more efficacious LMWCs is desirable. These agents are anticipated to be efficacious not only for the above-mentioned diseases but also for resistance to thyroid hormone and have utility for thyroid cancer radionuclide scintigraphy/therapy as a new theranostic.
Objective: This study aimed to elucidate disproportionately low serum thyroglobulin (Tg) values in Tg antibody (TgAb)-positive patients with structural recurrence of papillary thyroid carcinoma (PTC) using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Design: A retrospective study was performed on 176 patients in whom Tg and TgAb levels were measured between 2016 and 2021. Several comprehensive analyses of Tg-LC-MS/MS with an electrochemiluminescence immunoassay for Tg (Tg-ECLIA) were conducted using serum samples. Methods: TgAb-positive patients who underwent total thyroidectomy with multiple lung metastases due to PTC were evaluated using Tg-LC-MS/MS and Tg-ECLIA. Tg expression in lymph node metastases and metastatic lesions was evaluated by immunohistochemistry and Tg levels of aspiration washouts. Two in vitro assays were performed to elucidate TgAb interference. Results: Tg concentrations of negative TgAb in both assays were similar (R2=0.99; n=52). Patients with structural recurrence showed higher Tg values with Tg-LC-MS/MS than with Tg-ECLIA. The undetectable proportion was significantly lower with Tg-LC-MS/MS (31.6%, 6/19) than with Tg-ECLIA (68.4%, 13/19; p=0.023). The spike-recovery rate and Tg concentrations determined by the serum mixture text (n=29) were significantly reduced to 75.0% (118.3% to 88.7%) and 81.3% (107.0% to 87.0%), respectively, with TgAb using Tg-ECLIA (both p<0.001) confirming assay interference, but not using Tg-LC-MS/MS (91.8 to 92.3%, p=0.77 and 98.4 to 100.8%, p=0.18, respectively). Conclusions: TgAb had no effect on the Tg-LC-MS/MS assay, but yielded 19%–25% lower values in Tg-ECLIA. Tg-LC-MS/MS is preferable for monitoring serum Tg levels in TgAb-positive patients, although those with structural recurrence often had disproportionally low Tg values.
Nephrotic syndrome (NS) is characterized by massive urinary protein leakage and associated hypoproteinemia due to increased protein permeability caused by impaired renal glomerular connections. Although there have been several sporadic reports regarding the relationship between NS and thyroid dysfunction, a consensus has yet to be reached. The mechanism of hypothyroidism in NS is attributed to the loss of protein-bound thyroid hormones, such as thyroxine-binding globulin, transthyretin, and albumin, into the urine. Herein, we report four adults with hypothyroidism that developed or worsened due to the onset of NS. The patients' underlying thyroid status was post-total thyroidectomy with supplemental levothyroxine (L-T 4 ) in two patients, hypothyroidism with supplemental L-T 4 due to Hashimoto's disease in one patient, and Hashimoto's disease with normal thyroid function in one patient. Our results suggest that the presence of a reduced thyroid reserve may predispose patients to hypothyroidism in NS. We conclude that NS may cause or exacerbate hypothyroidism. In such cases, an NS assessment, including a urine test, is required.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.