Introduction: Rapid diagnosis is fundamental for epidemiological control of Cholera disease. Contradictorily the gold standard test (stool culture) takes several days. Finlay Vaccine Institute obtained an Immunoagglutination test for rapid diagnosis of Cholera (FCIT), based on a monoclonal antibody anti-LPS O1 coupled to latex particles. FCIT, includes a positive control (LPS O1 Ogawa), which quantifi cation is mandatory to obtain the registration of the test.The objective of the work was to develop a quantitative Dot Blot to determine the LPS O1 concentration in FCIT Positive control, using a peroxidase-conjugated mAb. Materials and Methods:Conjugation of mAb anti LPS O1 to peroxidase enzyme was carry out by periodate method. Quantitation of LPS O1 was accomplish by quantity Dot Blot. For capture Vibrio cholerae 569B Lipopolysaccharides from Sigma, was used as standard of the curve (40 μg/mL to 0.6 μg/ mL) and fi ve lots of FCIT positive control were applied as sample. For detection conjugated mAb-HRP was employed at dilution 1:5000. The development of the reaction was carried out using SIGMAFAST™ DAB Tablet. The images were captured using the GS-800 densitometer and the spots density (Int/mm 2 ) were calculated using the ImageJ software. The LPS concentration in positive control lots was calculated employed Ascent Software. Results:The mAb was conjugated to the HRP effi ciently with working dilutions range from 1:2500 to 1:10,000. A four-parameter fi t model curve was obtained with R 2 of 0.99. Of the fi ve FCIT positive control lots evaluated, four complied with 30% of the expected concentration, for an 80% effectiveness of the technique. Conclusions:These results suggest that the quantitative Dot Blot using the mAbC anti Vibrio cholerae LPS O1, can be employed for the quantifi cation of LPS in batches of the FCIT positive control, from the purifi cation and production stages, as well as for the stability evaluation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.