AimsTo evaluate the accuracy of the ISNT rule (I=inferior, S=superior, N=nasal, T=temporal) and its variants with neuroretinal rim width and retinal nerve fibre layer (RNFL) thickness measurements differentiating normal from glaucomatous eyes.MethodsThe diagnosis accuracy of the ISNT rule and its variants was evaluated in a population-based study. Neuroretinal rim widths were measured on monoscopic optic disc photographs with an image-processing program. RNFL thickness measurements were obtained with spectral-domain optical coherence tomography (SD-OCT).ResultsIn this study including 940 normal subjects and 93 patients with glaucoma, the sensitivity of the ISNT rule with optic disc photographs was 94.1% (95% CI 90.2 to 98.1), whereas its specificity was 49.2% (46.9 to 51.6). When using the IST rule, the sensitivity decreased to 69.9% (62.1 to 77.6) with a higher specificity, 87.0% (85.3 to 88.6). All the diagnosis indicators were somewhat lower for the different rules using RNFL thickness: the sensitivity of the ISNT rule was 79.4% (72.6 to 86.2) and its specificity was 34.1% (31.9 to 36.4). With the IST rule, the sensitivity decreased to 50.0% (41.6 to 58.4) while the specificity increased to 64.9% (62.7 to 67.2).ConclusionsThe ISNT and IST rules applied to neuroretinal rim width measurement by optic disc photographs are useful and simple tools for differentiating normal from glaucomatous eyes. The translation of these rules to RNFL thickness by SD-OCT is of limited value.
Purpose To develop a risk‐prediction nomogram based on baseline variables for good functional response during the 1st year of treatment with anti‐VEGF agents in naive diabetic macular oedema (DME). Methods This retrospective study included patients presenting naive‐DME treated with anti‐VEGF therapy at Dijon University Hospital (France) between 1 February 2012 and 31 March 2015 (derivation cohort). We studied baseline variables that had significant associations with a good functional response to anti‐VEGF agents during the 1st year of treatment. We used a program to generate a nomogram based on a binary logistic regression predictive model. Then, this nomogram was tested on data from a separate cohort of naive‐DME patients from a multicenter study involving 20 French ophthalmologic centres between January 2014 and June 2015 (validation cohort). Results Age, baseline BCVA and ellipsoid zone integrity on spectral‐domain optical coherence tomography (SD‐OCT) are functional prognostic factors and were used to build a nomogram. The nomogram showed excellent discrimination for good functional responders (area under the curve (AUC) = 0.906, 95% confidence interval (95% CI) = [0.849–0.964], p = 0.004). The discriminative power of this nomogram was tested on the validation cohort data, demonstrating good discrimination of good functional responders (AUC = 0.942, 95% CI = [0.898–0.986], p < 0.001). Conclusion This nomogram provides a useful estimation of a good functional response in naive‐DME patients treated with anti‐VEGF agents.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.