Background: Porous tantalum augments are versatile tools in reconstructing complex acetabular defects during revision total hip arthroplasty (THA). This study examines the clinical and radiographic outcomes of porous tantalum augments placed in the type I (flying buttress) configuration at two to 17-year followup in the largest cohort to-date in the literature. Methods: We retrospectively analyzed 59 consecutive revision THAs involving the use of flying buttress augments between 2003 and 2018. The mean patient age and follow-up duration were 63.9 ± 11.6 years (range, 35-87) and 8 years (range, 2-17), respectively. The Oxford hip score was used to assess clinical outcome. The modified Moore classification was used to assess acetabular augment and shell osseointegration. Kaplan-Meier survival analysis with 95% confidence interval (CI) was used to assess implant survivorship. Results: The mean Oxford hip score improved from 15.9 ± 6.2 preoperatively to 35.0 ± 6.5 at a mean follow-up of eight years (P < .0001). Radiographic assessment using the modified Moore classification demonstrated five signs of osseointegration in 49 hips (83.1%), four signs in six hips (10.2%), three signs in one hip (1.7%), and one sign in one hip (1.7%). Kaplan-Meier analysis demonstrated ten-year survivorship of 88.9% (95% CI 74.4-95.4) with all-cause revision as end point and 94.3% (95% CI 83.1-98.2) with revision for acetabular aseptic loosening as end point. Conclusion: Treatment of superolateral acetabular defects during revision THA using porous tantalum augments placed in the type I (flying buttress) configuration provides excellent implant survivorship and favorable clinical outcomes at mid-term follow-up.
Background As the healthcare system faced an acute shortage of personal protective equipment (PPE) during the COVID-19 pandemic, the use of 3D printing technologies became an innovative method of increasing production capacity to meet this acute need. Due to the emergence of a large number of 3D printed face shield designs and community-led PPE printing initiatives, this case study examines the methods and design best optimized for community printers who may not have the resources or experience to conduct such a thorough analysis. Case presentation We present the optimization of the production of 3D printed face shields by community 3D printers, as part of an initiative aimed at producing PPE for healthcare workers. The face shield frames were manufactured using the 3DVerkstan design and were coupled with an acetate sheet to assemble a complete face shield. Rigorous quality assurance and decontamination protocols ensured community-printed PPE was satisfactory for healthcare use. Conclusion Additive manufacturing is a promising method of producing adequate face shields for frontline health workers because of its versatility and quick up-start time. The optimization of stacking and sanitization protocols allowed 3D printing to feasibly supplement formal public health responses in the face of a global pandemic.
The COVID-19 pandemic has led to persistent supply shortages of respiratory protective equipment in many jurisdictions. Reusable industrial respirators have been proposed and deployed as an alternative, but also face severe supply limitations. In addition, industrial respirators do not filter the user’s expired breath, a major limitation in health care settings where bidirectional protection is required. We present the development and quantitative testing of a reusable silicone respirator that can be locally manufactured using low-cost desktop infrastructure. Using standardized quantitative fit-testing (QNFT including resting and activity components according to CSA Z94.4-18) in a cohort of 41 healthcare workers (HCWs), we compared the performance of the mask to the individually-fitted disposable N95 masks that the HCWs had been assigned by our institution. Overall QNFT pass rates for disposable N95 respirators were 58.5% vs. 100% for the reusable mask. For a production run of 1000 masks, unit cost is approximately $25 CAD in materials and 35 minutes in labor per mask. The device requires further testing to assess flow resistance, carbon dioxide rebreathing, and full conformance with technical standards required for regulatory approval.
Introduction The COVID-19 pandemic has led to widespread shortages of N95 respirators and other personal protective equipment (PPE). An effective, reusable, locally-manufactured respirator can mitigate this problem. We describe the development, manufacture, and preliminary testing of an open-hardware-licensed device, the “simple silicone mask” (SSM). Methods A multidisciplinary team developed a reusable silicone half facepiece respirator over 9 prototype iterations. The manufacturing process consisted of 3D printing and silicone casting. Prototypes were assessed for comfort and breathability. Filtration was assessed by user seal checks and quantitative fit-testing according to CSA Z94.4–18. Results The respirator originally included a cartridge for holding filter material; this was modified to connect to standard heat-moisture exchange (HME) filters (N95 or greater) after the cartridge showed poor filtration performance due to flow acceleration around the filter edges, which was exacerbated by high filter resistance. All 8 HME-based iterations provided an adequate seal by user seal checks and achieved a pass rate of 87.5% (N = 8) on quantitative testing, with all failures occurring in the first iteration. The overall median fit-factor was 1662 (100 = pass). Estimated unit cost for a production run of 1000 using distributed manufacturing techniques is CAD $15 in materials and 20 minutes of labor. Conclusion Small-scale manufacturing of an effective, reusable N95 respirator during a pandemic is feasible and cost-effective. Required quantities of reusables are more predictable and less vulnerable to supply chain disruption than disposables. With further evaluation, such devices may be an alternative to disposable respirators during public health emergencies. The respirator described above is an investigational device and requires further evaluation and regulatory requirements before clinical deployment. The authors and affiliates do not endorse the use of this device at present.
Resumo Objetivo Este estudo avaliou diferenças entre parafusos com rosca total ou parcial na resistência à compressão interfragmentar inicial. Nossa hipótese era de que haveria maior perda de resistência à compressão inicial com o parafuso de rosca parcial. Métodos Uma linha de fratura oblíqua de 45 graus foi criada em amostras de osso artificial. O primeiro grupo (TOTAL, n = 6) foi fixado com um parafuso de 3,5 mm de rosca total, enquanto o segundo grupo (PARCIAL, n = 6) usou um parafuso de 3,5 mm de rosca parcial. Avaliamos a rigidez à torção em ambas as direções de rotação. Os grupos foram comparados com base nos seguintes parâmetros biomecânicos: momento de rigidez-ângulo, momento de rigidez-tempo, momento de torção máxima (carga de falha) e força de compressão calibrada com base na medida do sensor de pressão. Resultados Depois da perda de uma amostra PARCIAL, não foram observadas diferenças estatisticamente significativas na força de compressão calibrada entre os 2 grupos [mediana (intervalo interquartil)]: TOTAL: 112,6 (10,5) N e PARCIAL: 106,9 (7,1) N, com p = 0,8 segundo o teste U de Mann-Whitney). Além disso, após a exclusão de 3 amostras para testes mecânicos (TOTAL, n = 5, PARCIAL, n = 4), não foram observadas diferenças estatisticamente significativas entre os construtos TOTAL e PARCIAL quanto ao momento de rigidez-ângulo, momento de rigidez-tempo ou momento de torção máxima (carga de falha). Conclusão Não há diferença aparente na força de compressão inicial (força de compressão ou rigidez do construto ou carga de falha) com o uso de parafusos de rosca total ou parcial neste modelo biomecânico em osso artificial de alta densidade. Parafusos de rosca total podem, portanto, ser mais úteis no tratamento de fraturas diafisárias. Mais pesquisas são necessárias sobre o impacto em modelos ósseos osteoporóticos ou metafisários de menor densidade e avaliação do significado clínico.
Surgical complications were classified as arterial, venous, ureteral, lymphatic, suture dehiscence, and/or need for early graft removal (defined as removal in the first 3 months after transplantation). The cause of early graft removal was noted and categorized as either a surgical or non-surgical complication.RESULTS: A total of 100 kidneys were implanted from DCD/ ECMO, 108 from DBD/SCD and 115 from DBD/ECD.Despite a higher rate of DGF in DCD/ECMO groups vs DBD/SCD and DBD/EDC (65,9% vs 28,1% vs 30,8%; p<0,001), there were no differences in renal function between groups 12 months after transplantation. There were no statistically significant differences in surgical complications. Early graft removal was lower in DBD-SCD group. DCD/ECMO group had a significantly more early graft removals of non-surgical cause due to tubular necrosis, humoral rejection or infection, while DBD/ECD had a significantly more early graft removals of surgical cause due to arterial/ venous thrombosis and hemorrhage.CONCLUSIONS: Kidney transplantation from DCD/ECMO can be a viable option. Despite higher rates of DGF in DCD/ECMO, those whose grafts survive have a similar renal function in the medium-to-long term. Early graft removal was mainly associated with a non-surgical cause, probably related to ischemia lesion caused by prolonged warm ischemia time and/or ischemia-reperfusion injury induced by the ECMO.
Appendico-vesical fistula (AVF) is an uncommon type of enterovesical fistula that can present with symptoms of recurrent or persistent urinary tract infection (UTI) and, in some instances, with gastrointestinal symptoms. AVFs occur more commonly in males and are mainly attributed to unrecognized or conservatively managed appendicitis.1 Herein, we describe a case of a 21-year-old male who presented with fevers, urgency, and hematuria and on extensive workup was found to have an AVF requiring surgical repair. Drawing from our case and the literature, we conclude that AVF occurs rarely and requires a high index of suspicion among physicians. Past medical history of previous acute appendicitis and UTIs with or without gastrointestinal symptoms should raise suspicion for AVF.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.