BACKGROUNDTranscatheter device closure of ventricular septal defect (VSD) has become an attractive alternative to surgery. We report here on our early experiences of transcatheter closure of VSD using Cocoon devices, which are now available in Korea.METHODSWe reviewed the medical records and angiographic images of 13 patients who underwent transcatheter closure of VSD with a Cocoon occluder at Samsung Medical Center. The median patient age was 5.8 years, and the median patient weight was 20.3 kg.RESULTSThe device was successfully implanted in all patients. The follow-up period was 10 ± 6 months, and no mortality was observed. An immediate residual leak on the next day was detected in 7 patients (including 4 with perimembranous VSD). However, 6 months later, a residual leak was observed only in 2 patients with perimembranous VSD and 1 patient with muscular VSD. Early conduction abnormalities were observed in 3 patients, all of whom had perimembranous VSD, but no significant complete atrioventricular block was observed. One patient experienced newly developed significant aortic regurgitation that decreased spontaneously but still existed at the 6 month follow-up. No hemolysis or embolization was noted on the next day or during the follow-up period.CONCLUSIONSCocoon devices can be used safely and effectively for VSD closure. However, residual leaks and conduction abnormalities may occur early after implantation, especially in patients with perimembranous VSD. Although normal conduction was recovered, long-term evaluation remains essential.
Implantable cardioverter defibrillator as a treatment for massive left ventricular fibroma-induced ventricular arrhythmia in a childPediatric cardiac tumors are rare. Among these, cardiac fibroma is the second most common. Its clinical manifestations depend on size and location of the tumor and include arrhythmia or obstruction to blood flow. Symptomatic cardiac fibroma is generally treated with surgical resection or cardiac transplantation. We present the case of a 12-year-old boy with a lethal ventricular arrhythmia induced by a remnant tumor that was previously partially resected. An implantable cardioverter defibrillator was inserted as the arrhythmia was resistant to medical treatment. He was discharged in stable condition with an implantable cardioverter defibrillator generator and followed up in the outpatient clinic.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.