A nocturnal maximum in rainfall and thunderstorm activity over the central Great Plains has been widely documented, but the mechanisms for the development of thunderstorms over that region at night are still not well understood. Elevated convection above a surface frontal boundary is one explanation, but this study shows that many thunderstorms form at night without the presence of an elevated frontal inversion or nearby surface boundary. This study documents convection initiation (CI) events at night over the central Great Plains from 1996 to 2015 during the months of April–July. Storm characteristics such as storm type, linear system orientation, initiation time and location, and others were documented. Once all of the cases were documented, surface data were examined to locate any nearby surface boundaries. The event’s initiation location relative to these boundaries (if a boundary existed) was documented. Two main initiation locations relative to a surface boundary were identified: on a surface boundary and on the cold side of a surface boundary; CI events also occur without any nearby surface boundary. There are many differences among the different nocturnal CI modes. For example, there appear to be two main peaks of initiation time at night: one early at night and one later at night. The later peak is likely due to the events that form without a nearby surface boundary. Finally, a case study of three nocturnal CI events that occurred during the Plains Elevated Convection At Night (PECAN) field project when there was no nearby surface boundary is discussed.
During the Plains Elevated Convection at Night (PECAN) experiment, an isolated hailstorm developed on the western side of the PECAN study area on the night of 3–4 July 2015. One of the objectives of PECAN was to advance knowledge of the processes and conditions leading to pristine nocturnal convection initiation (CI). This nocturnal hailstorm developed more than 160 km from any other convective storms and in the absence of any surface fronts or bores. The storm initiated within 110 km of the S-Pol radar; directly over a vertically pointing Doppler lidar; within 25 km of the University of Wyoming King Air flight track; within a network of nine sounding sites taking 2-hourly soundings; and near a mobile mesonet track. Importantly, even beyond 100 km in range, S-Pol observed the preconvection initiation cloud that was collocated with the satellite infrared cloud image and provided information on the evolution of cloud growth. The multiple observations of cloud base, thermodynamic stability, and direct updraft observations were used to determine that the updraft roots were elevated. Diagnostic analysis presented in the paper suggests that CI was aided by lower-tropospheric gravity waves occurring in an environment of weak but persistent mesoscale lifting.
Polarimetric measurements recorded by a mobile X-band radar are combined with photographs of the Dodge City, Kansas, tornado to quantitatively document the evolving debris cloud. An inner annulus or tube of high radar reflectivity encircled the tornado at low levels. A column of low cross-correlation coefficient ρhv was centered on the funnel cloud during the early stage of the tornado’s life cycle. In addition, two areas of low ρhv were located near the inner annulus of high radar reflectivity and were hypothesized to be regions of high debris loading that have been reproduced in simulations of lofted debris. Another column of low ρhv was a result of strong wind speeds that were progressively lofting small debris and dust as inflow rotated around and within the weak echo notch of the hook echo. A column of negative differential reflectivity ZDR was also centered on the tornado and was hypothesized to result from common debris alignment. The polarimetric structure undergoes a dramatic transition when the debris cloud was prominent and enveloped most of the funnel cloud. The weak echo column (WEC) began to fill at lower levels as large amounts of debris were lofted into the circulation. The axis of minimum ρhv shifted to a radius just beyond the funnel cloud. A column of positive ZDR was collocated with the funnel surrounded by negative ZDR. The negative ZDR and low ρhv within the debris cloud were likely the result of some common debris alignment from wheat stems. The positive ZDR within the funnel signified the presence of a few hydrometeors.
The number of case studies in the literature of nocturnal convection has increased during the past decade, especially those that utilize high-spatiotemporal-resolution datasets from field experiments such as the International H2O Project (IHOP_2002) and Plains Elevated Convection at Night (PECAN). However, there are few case studies of events for convection initiation without a nearby surface boundary. These events account for approximately 25% of all nocturnal convection initiation (CI) events. Unique characteristics of these events include a peak initiation time later at night, a preferred initiation location in northern Kansas and southern Nebraska, and a preferred north–south orientation to linear convective systems. In this study, four case studies of convection that is initiated without a nearby surface boundary are detailed to reveal a number of possible initiation mechanisms, including quasigeostrophic-aided ascent, elevated ascent associated with convergent layers (of unknown causes), the low-level jet, and gravity waves. The case studies chosen illustrate the wide variety of synoptic-scale conditions under which these events can occur.
The maximum upward vertical velocity at the leading edge of a density current is commonly <10 m s−1. Studies of the vertical velocity, however, are relatively few, in part owing to the dearth of high spatiotemporal observations. During the Plains Elevated Convection at Night (PECAN) field project, a mobile Doppler lidar measured a maximum vertical velocity of 13 m s−1 at the leading edge of a density current created by a mesoscale convective system during the night of 15 July 2015. Two other vertically-pointing instruments recorded 8 m s−1 vertical velocities at the leading edge of the density current on the same night. This study describes the structure of the density current and attempts to estimate the maximum vertical velocity at their leading edges using the following properties: the density current depth, the slope of its head, and its perturbation potential temperature. The method is then be applied to estimate the maximum vertical velocity at the leading edge of density currents using idealized numerical simulations conducted in neutral and stable atmospheres with resting base states and in neutral and stable atmospheres with vertical wind shear. After testing this method on idealized simulations, this method is then used to estimate the vertical velocity at the leading edge of density currents documented in several previous studies. It was found that the maximum vertical velocity can be estimated to within 10-15% of the observed or simulated maximum vertical velocity and indirectly accounts for parameters including environmental wind shear and static stability.
In many instances, synchronization of Doppler radar data among multiple platforms for multiple-Doppler analysis is challenging. This study describes the production of dual-Doppler wind analyses from several case studies using data from a rapid-scanning, X-band, polarimetric, Doppler radar—the RaXPol radar—and data from nearby WSR-88Ds. Of particular interest is mitigating difficulties related to the drastic differences in scanning rates of the two radars. To account for differences in temporal resolution, a variational reflectivity tracking scheme [a spatially variable advection correction technique (SVAC)] has been employed to interpolate (in a Lagrangian sense) the coarser temporal resolution data (WSR-88D) to the times of the RaXPol volume scans. The RaXPol data and temporally interpolated WSR-88D data are then used to create quasi–rapid scan dual-Doppler analyses. This study focuses on the application of the SVAC technique to WSR-88D data to create dual-Doppler analyses of three tornadic supercells: the 19 May 2013 Edmond–Carney and Norman–Shawnee, Oklahoma, storms and the 24 May 2016 Dodge City, Kansas, storm. Results of the dual-Doppler analyses are briefly examined, including observations of the ZDR columns as a proxy for updrafts. Potential improvements to this technique are also discussed.
Vertical shear in the boundary layer affects the mode of convective storms that can exist if they are triggered. In western portions of the southern Great Plains of the United States, vertical shear, in the absence of any transient features, changes diurnally in a systematic way, thus leading to a preferred time of day for the more intense modes of convection when the shear, particularly at low levels, is greatest. In this study, yearly and seasonally averaged wind observations for each time of day are used to document the diurnal variations in wind at the surface and in the boundary layer, with synoptic and mesoscale features effectively filtered out. Data from surface mesonets in Oklahoma and Texas, Doppler wind profilers, instrumented tower data, and seasonally averaged wind data for each time of day from convection-allowing numerical model forecasts are used. It is shown through analysis of observations and model data that the perturbation wind above anemometer level turns in a clockwise manner with time, in a manner consistent with prior studies, yet the perturbation wind at anemometer level turns in an anomalous, counterclockwise manner with time. Evidence is presented based on diagnosis of the model forecasts that the dynamics during the early evening boundary layer transition are, in large part, responsible for the behavior of the hodographs at that time: as vertical mixing in the boundary layer diminishes, the drag on the wind at anemometer level persists, leading to rapid deceleration of the meridional component of the wind. This deceleration acts to turn the wind to the left rather than to the right, as would be expected from the Coriolis force alone.
The objectives of this study are to determine the finescale characteristics of the wind and temperature fields associated with a prefrontal wind-shift line and to contrast them with those associated with a strong cold front. Data from a mobile, polarimetric, X-band, Doppler radar and from a surveillance S-band radar, temperature profiles retrieved from a thermodynamic sounder, and surface observations from the Oklahoma Mesonet are used to analyze a prefrontal wind-shift line in Oklahoma on 11 November 2013. Data from the same mobile radar and the Oklahoma Mesonet are used to identify the finescale characteristics of the wind field associated with a strong surface cold front in Oklahoma on 9 April 2013. It is shown that the prefrontal wind-shift line has a kinematic and thermodynamic structure similar to that of an intrusion (elevated density current), while the cold front has a kinematic structure similar to that of a classic density current. Other characteristics of the prefrontal wind-shift line and front are also discussed. Evidence of waves generated at the leading edge of the prefrontal wind-shift line is presented.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.