BACKGROUNDA dental implant is utilised to hold the counterfeit tooth into its legitimate position in the human jaw. It fills the need of characteristic root which is there in a normal tooth. Implant design, implant stability, materials used in dental implants are the main factors required for the long-haul accomplishment of a dental implant.The aim of this article is to give a brief review on dental implant materials, implant design, numerical approach used in dental implants by the researchers over the years.
Background: Implant thread profile plays a vital role in magnitude and distribution of contact stresses at the implant-bone interface. The main goal of this study was to evaluate the biomechanical effects of four distinct thread profiles of a dental implant in the mandibular premolar region.
Methods: The dental implant represented the biocompatible Zirconia material and the bone block was modelled as transversely isotropic and elastic material. Three-dimensional finite element simulations were conducted for four distinct thread profiles of a dental implant at 50%, 75%, and 100% osseointegration. An axial static load of 500 N was applied on the abutment surface to estimate the stresses acting within the bones surrounding the implant.
Results: Regions of stress concentration were seen mostly along the mesiodistal direction compared to that in the buccolingual direction. The cortical bone close to the cervical region of the implant and the cortical bone next to the first thread of the implant experienced peak stress concentration. Increasing the degree of osseointegration resulted in increased von-Mises stresses on the implant-cortical transition region, the implant-cancellous transition region, the cortical bone, and the cancellous bone.
Conclusion: The results show that the application of distinct thread profiles at different degrees of osseointegration had significant effect on the stresses distribution contours in the surrounding bony structure. Comparing all four thread profiles, a dental implant with V-thread profile induced lower values of von-Mises stresses and shear stresses on the implant-cortical transition region, implant-cancellous transition region, cortical bone, and cancellous bone.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.