In this study, we adopted the solution combustion method to synthesize magnesium ferrite (MgFe2O4) using urea as the fuel. Various techniques including TGA, XRD, SEM, TEM, FTIR, UV-Vis DRS, and EDS were employed to characterize the synthesized MgFe2O4 nanoparticles. The XRD analysis revealed that single-phase MgFe2O4 was formed at a calcination temperature of at 500–600°C for 3 hours in the absence of an intermediate phase. TEM analysis also revealed the formation of monodisperse magnesium ferrite nanoparticles, averaged at 30 nm in size. The photocatalytic activity of the synthesized MgFe2O4 nanoparticles against methylene blue dye under visible light was investigated, showing the efficiency of 89.73% after 240 minutes of light irradiation with the presence of H2O2.
The bottom-hole zone treatment to eliminate contaminating materials is one of the most effective measures to improve oil and gas exploitation efficiency. At Joint Venture Vietsovpetro, in addition to utilizing of traditional acid systems to treat the bottom-hole zone, researchs and applications of new technologies have been conducted to improve treatment efficiency, especially for wells with specific conditions and wells which are entering the final stage of exploitation. In this report, the results of research and assessments of the effectiveness of the chemical systems currently used by Vietsovpetro and the results of research and applications of some new technological solutions in this field in the period 2015-2019 will be presented
Background: The process of using proximal bone in hip arthroplasty will allow the remaining bone to be preserved in future surgeries. To take advantage of these advantages, many types of short stem prosthetics have been developed in recent years. The obtained survey parameters combined with the obtained anatomical parameters shown that the Spiron joint is suitable when applied to adult Vietnamese.Research subjects and methods: The anatomical dimensions of the hip joint related to Spiron joint replacement were analyzed by the authors.Results: The anatomical results with Spiron showed that the acetabular average diameter and tilt angle were 49.77 mm and 41.55°. The femoral neck-to-body angle, the femoral upper-neck diameter, the distance from the crest to the hard shell along the femoral neck axis was on average 131.52°, 34, 32mm, and 51.39mm, respectively. The offset distance from the center of the crest to the axis of the femur is 38.33mm. These parameters show the working ability as well as stability when replaced by the Spiron joint.Conclusion: When applied to adult Vietnamese, the femoral neck diameter is consistent with the Spiron diameter. Preoperative planning is needed to check the femoral neck angle and femoral neck length prior to surgery to see if the Spiron joint replacement is eligible. The findings of this study support the assumption that it is feasible to use Spiron prostheses in joint replacement in Vietnamese adults.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.