Introduction There are few reports of injury to the soft palate and retropharynx sustained during intubation with the GlideScope® video laryngoscope. Most reports are of isolated injury to the soft palate. Case History We describe a patient in whom the retropharynx was injured but the extent of the injury was not observed initially. The patient did not suffer severe sequelae from this injury. However, this injury can cause serious sequelae if it is not recognised (eg development of a retropharyngeal abscess). Conclusions We recommend that any patient who sustains injury to the soft palate during intubation (particularly if the endotracheal tube passes through the soft palate) should be reviewed an otolaryngologist before removal of the endotracheal tube.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.