Dual-chamber minimal ventricular pacing, as compared with conventional dual-chamber pacing, prevents ventricular desynchronization and moderately reduces the risk of persistent atrial fibrillation in patients with sinus-node disease. (ClinicalTrials.gov number, NCT00284830 [ClinicalTrials.gov].).
The combination of three atrial prevention pacing algorithms did not decrease device classified atrial tachyarrhythmia frequency or burden during a 3-month cross-over period in bradycardic patients and septal or nonseptal atrial pacing leads. Prevention pacing was associated with decreased frequency of premature atrial contractions and with decreased symptomatic atrial tachyarrhythmia frequency in patients with atrial septal leads.
The incidence of AT in pacemaker recipients is high. Most device-detected AHRE are asymptomatic. Prior history of AT is associated with higher arrhythmia burden. AHRE diagnostics have a high positive predictive value for identifying AT events.
Coronary stents improve resting blood flow and flow reserve in the presence of stenoses, but the impact of these devices on fluid dynamics during profound vasodilation is largely unknown. We tested the hypothesis that stent implantation affects adenosine-induced alterations in coronary hemodynamics and wall shear stress in anesthetized dogs (n = 6) instrumented for measurement of left anterior descending coronary artery (LAD) blood flow, velocity, diameter, and radius of curvature. Indexes of fluid dynamics and shear stress were determined before and after placement of a slotted-tube stent in the absence and presence of an adenosine infusion (1.0 mg/min). Adenosine increased blood flow, Reynolds (Re) and Dean numbers (De), and regional and oscillatory shear stress concomitant with reductions in LAD vascular resistance and segmental compliance before stent implantation. Increases in LAD blood flow, Re, De, and indexes of shear stress were observed after stent deployment (P < 0.05). Stent implantation reduced LAD segmental compliance to zero and potentiated increases in segmental and coronary vascular resistance during adenosine. Adenosine-induced increases in coronary blood flow and reserve, Re, De, and regional and oscillatory shear stress were attenuated after the stent was implanted. The results indicate that stent implantation blunts alterations in fluid dynamics during coronary vasodilation in vivo.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.