These findings show mild inflammatory and prothrombic responses and are suggestive of alterations in cardiac repolarization induced by UFCAP inhalation.
E-cigarettes containing ‘nicotine salts’ aim to increase smoker’s satisfaction by improving blood nicotine delivery and other sensory properties. Here, we evaluated the pharmacokinetic profiles and subjective effects of nicotine from two e-cigarette device platforms with varying concentrations of nicotine lactate (nicotine salt) e-liquid relative to conventional cigarettes. A randomised, open-label, cross-over clinical study was conducted in 15 healthy US adult smokers. Five different e-cigarette products were evaluated consecutively on different days after use of own brand conventional cigarette. Plasma nicotine pharmacokinetics, subjective effects, and tolerability were assessed following controlled use of the products. The rate of nicotine absorption into the bloodstream was comparable from all e-cigarettes tested and was as rapid as that for conventional cigarette. However, in all cases, nicotine delivery did not exceed that of the conventional cigarette. The pharmacokinetic profiles of nicotine salt emissions were also dependent upon the properties of the e-cigarette device. Subjective scores were numerically highest after smoking a conventional cigarette followed by the my blu 40-mg nicotine salt formulation. The rise in nicotine blood levels following use of all the tested e-cigarettes was quantified as ‘a little’ to ‘modestly’ satisfying at relieving the desire to smoke. All products were well tolerated with no notable adverse events reported. These results demonstrate that, while delivering less nicotine than a conventional cigarette, the use of nicotine salts in e-cigarettes enables cigarette-like pulmonary delivery of nicotine that reduces desire to smoke.
Changes in fifteen urine, blood and exhaled breath BoEs of HPHCs representing classes of compounds reported by FDA to be significant contributors to smoking-associated disease risks were measured in 105 clinical-confined subjects following randomization and a five-day forced-switch from usual brand conventional combustible cigarettes to: (i) exclusive commercial e-cigarette use; (ii) dual-use of commercial e-cigarettes and the subject’s usual cigarette brand; or (iii) discontinued use of all tobacco or nicotine products. Levels of urinary biomarkers in subjects that completely substituted their usual cigarette with e-cigarettes were significantly lower (29–95%) after 5 days. Percent reductions in eight of nine urinary BoEs were indistinguishable to smokers who had quit smoking, except for nicotine equivalents, which declined by 25–40%. Dual users who halved self-reported daily cigarette consumption with e-cigarettes exhibited reductions (7–38%) in eight of nine urinary biomarkers, but had increase (1–20%) in nicotine equivalents. Reductions were broadly proportional to the reduced numbers of cigarettes smoked. Dual user urinary nicotine equivalents were slightly higher, but not statistically significant. After 5 days, blood nicotine biomarker levels were lower in the cessation (75–96%) and exclusive use groups (11–83%); with dual users experiencing no significant reductions. All subjects experienced significant decreases in exhaled CO. Decreases in the cessation and exclusive groups ranged from 88–89% and 27–32% in dual users. Exhaled NO increased in the cessation and exclusive groups (46–63% respectively), whereas the dual users experienced minimal changes. Overall, smokers who completely or partially substituted conventional cigarettes with e-cigarettes over five days, experienced reductions in HPHCs.
RationaleElectronic cigarettes (ECs) are becoming popular alternatives for smokers, but there has been limited study of their abuse liability.ObjectivesThe objective of this study was to evaluate the abuse liability of three Vuse Solo ECs, ranging from 14 to 36 mg in nicotine content, relative to high- and low-abuse liability comparator products (usual brand combustible cigarettes and nicotine gum, respectively) in a group of 45 EC-naïve smokers.MethodsEnrolled subjects’ ratings of subjective effects and nicotine uptake over 6 h were used to measure abuse liability and pharmacokinetics following in-clinic use of each EC.ResultsUse of Vuse Solo resulted in subjective measures and nicotine uptake that were between those of combustible cigarettes and nicotine gum, although generally closer to nicotine gum. Compared to combustible cigarettes, use of Vuse Solo resulted in significantly lower scores in measures of product liking, positive effects, and intent to use again. These pharmacodynamic findings were consistent with the pharmacokinetic data, showing that cigarettes produced substantially faster and higher levels of nicotine uptake as compared to Vuse Solo and nicotine gum. Vuse Solo resulted in more rapid initial uptake of nicotine compared to nicotine gum, but peak concentration and long-term extent of uptake were not different or were lower with Vuse.ConclusionsCollectively, these findings suggest that Vuse Solo likely has an abuse liability that is somewhat greater than nicotine gum but lower than cigarettes.Trial registration ClinicalTrials.gov identifier: NCT02269514Electronic supplementary materialThe online version of this article (doi:10.1007/s00213-017-4665-y) contains supplementary material, which is available to authorized users.
Background and ObjectiveExposure to fine airborne particles (PM2.5) has been shown to be responsible for cardiovascular and hematological effects, especially in older people with cardiovascular disease. Some epidemiological studies suggest that individuals with diabetes may be a particularly susceptible population. This study examined effects of short-term exposures to ambient PM2.5 on markers of systemic inflammation, coagulation, autonomic control of heart rate, and repolarization in 22 adults (mean age: 61 years) with type 2 diabetes.MethodsEach individual was studied for four consecutive days with daily assessments of plasma levels of blood markers. Cardiac rhythm and electrocardiographic parameters were examined at rest and with 24-hour ambulatory ECG monitors. PM2.5 and meteorological data were measured daily on the rooftop of the patient exam site. Data were analyzed with models adjusting for season, weekday, meteorology, and a random intercept. To identify susceptible subgroups, effect modification was analyzed by clinical characteristics associated with insulin resistance as well as with oxidative stress and by medication intake.ResultsInterleukin (IL)-6 and tumor necrosis factor alpha showed a significant increase with a lag of two days (percent change of mean level: 20.2% with 95%-confidence interval [6.4; 34.1] and 13.1% [1.9; 24.4], respectively) in association with an increase of 10 μg/m3 in PM2.5. Obese participants as well as individuals with elevated glycosylated hemoglobin, lower adiponectin, higher ferritin or with glutathione S-transferase M1 null genotype showed higher IL-6 effects. Changes in repolarization were found immediately as well as up to four days after exposure in individuals without treatment with a beta-adrenergic receptor blocker.ConclusionsExposure to elevated levels of PM2.5 alters ventricular repolarization and thus may increase myocardial vulnerability to arrhythmias. Exposure to PM2.5 also increases systemic inflammation. Characteristics associated with insulin resistance or with oxidative stress were shown to enhance the association.
Introduction This study examined changes in biomarkers of exposure (BoE) after 5 days of nicotine-salt pod system (NSPS) use, compared with continuation of usual-cigarette smoking and cigarette abstinence, among adult combustible cigarette smokers. Aims and Methods A randomized, open-label, parallel-cohort, confinement study of healthy adult smokers, naive to NSPS use, was conducted. Participants (N = 90) were randomized to six cohorts (n = 15 each): exclusive ad libitum use of NSPS (four flavors: Virginia Tobacco, Mint, Mango, Creme), continuation of usual-brand cigarette smoking, or cigarette abstinence. Total nicotine equivalents and BoE (NNN, NNAL, 3-HPMA, MHBMA, S-PMA, HMPMA, CEMA, 1-OHP, and COHb) were measured. Results Eight non-nicotine BoEs, measured in urine, were reduced by an aggregate of 85.0% in the pooled NSPS cohort; increased by 14.4% in the cigarette cohort (p < .001 for pooled NSPS vs. cigarette); and reduced by 85.3% in the abstinence cohort (p > .05; 99.6% relative reduction between pooled NSPS vs. abstinence). Similar changes in individual BoEs were also observed (p < .001 for each BoE between pooled NSPS vs. cigarettes; and abstinence vs. pooled NSPS; p > .05 for each BoE between pooled NSPS vs. abstinence). Blood COHb decreased by 71.8% in the pooled NSPS cohort and 69.1% in the abstinence cohort (p > .05) and increased by 13.3% in the cigarette cohort (p < .001). Mean total urine nicotine equivalents increased in the pooled NSPS and cigarette cohorts by 9% and 26%, respectively, and did not significantly differ (p > .05). Conclusion Complete switching from cigarettes to NSPS produced significant reductions in key non-nicotine BoEs associated with cigarette smoking. Implications The results of this study concorded with evidence that complete switching from combustible cigarettes to tobacco and nontobacco-flavored vapor products may reduce exposure to key carcinogens and other toxicants known to be associated with tobacco-related diseases. Future research is needed to assess the long-term health effects of NSPS use. These results should not be interpreted to mean that the use of NSPS is without any risk, particularly for nonusers of tobacco products.
BackgroundElectronic cigarettes (e-cigarettes) are popular alternatives to conventional cigarettes among adult smokers wishing to reduce their exposure to harmful smoke constituents. However, little information exists on the relative internal exposures resulting from the exclusive or dual use of e-cigarettes.MethodsMeasurements of product use; adverse events; changes in smoking urge; and blood, urine and exhaled breath biomarkers of exposure (BoE) representing toxicants believed to contribute to smoking related diseases were made at baseline and after five days of product use in 105 clinically-confined smokers randomized into groups that partially or completely substituted their usual brand combustible cigarette with commercial e-cigarettes, or discontinued all nicotine and tobacco products.ResultsSubjects switching to e-cigarettes had significantly lower levels (29 %–95 %) of urinary BoEs after 5 days. Nicotine equivalents declined by 25 %–40 %. Dual users who substituted half of their self-reported daily cigarette consumption with e-cigarettes experienced 7 %–38 % reductions, but had increases (1 %–20 %) in nicotine equivalents. Blood nicotine biomarker levels were lower in the cessation (75 %–96 %) and e-cigarette use groups (11 %–83 %); dual users had no significant reductions. All groups experienced significant decreases in exhaled CO (27 %–89 %). Exhaled NO increases (46 %–63 %) were observed in the cessation and e-cigarette use groups; dual users had minimal changes. By Day 5, all groups had greater reductions in smoking urge compared to cessation. However, reductions were larger in the dual use group. No serious adverse events were observed.ConclusionsExposures to harmful smoke toxicants were observed to be lower in smokers who completely or partially replaced their cigarettes with e-cigarettes over five days.
RationaleWe previously reported that following a short-term product use period, use of non-menthol Vuse Solo electronic cigarettes (ECs) resulted in product effect-related subjective responses and nicotine uptake between those of combustible cigarettes (high-abuse liability comparator) and nicotine gum (low-abuse liability comparator); the results were generally closer to those of nicotine gum.ObjectiveUsing a similar design to the previous study, we evaluated the abuse liability of three menthol-flavored Vuse Solo ECs with the same nicotine contents (14, 29, and 36 mg) in a group of EC-naïve, menthol cigarette smokers, relative to comparator products.MethodsSix-hour nicotine uptake and ratings of subjective effects were used to determine abuse liability and pharmacokinetics.ResultsUse of menthol Vuse Solo resulted in significantly lower responses to subjective measurements (product liking, intent to use product again, and liking of positive product effects), higher urge to smoke responses, and a lower peak (Cmax) and overall extent (AUC0–360) of nicotine uptake compared to smoking the usual brand menthol cigarette. When compared with use of nicotine gum, subjective responses to use of menthol Vuse ECs were in the same direction as those resulting from smoking cigarettes but were more similar to nicotine gum use in magnitude than they were to cigarettes.ConclusionThese findings are concordant with our previous results and provide evidence that menthol Vuse Solo ECs have abuse liability that is lower than menthol cigarettes and potentially greater than that of nicotine gum.Trial registrationClinicalTrials.gov identifier: NCT02664012Electronic supplementary materialThe online version of this article (10.1007/s00213-018-4904-x) contains supplementary material, which is available to authorized users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.