A term male newborn, appropriate for gestational age, developed hypothermia, severe cardiac dysrrhythmia, and nonoliguric hyperkalemia within 24 hours of birth. Despite the prenatal identification of cystic renal dysplasia without oligohydramnios, at birth, a solitary left leg vascular hemangioma and large palpable kidneys were the only anomalies. Gradually hypotonia, lethargy, and poor feeding developed and by 20 hours of age recurrent cardiac dysrrhythmias, myocardial dysfunction, and renal insufficiency with intermittent hyperkalemia were apparent. Episodes of apnea developed on day 7 followed by respiratory failure, recurrent cardiac dysrrhythmias, and death on day 12. Eventually laboratory and autopsy findings confirmed the diagnosis of lethal neonatal carnitine palmitoyltransferase II deficiency.
To date, attempted balloon dilation of stenotic standard Blalock-Taussig shunts has been largely disappointing. It has been suggested that this may be due to the use of balloons of insufficient diameter. Balloon dilation of stenotic Blalock-Taussig shunts was attempted with use of relatively large balloons in five patients (11 to 67 months old) with cyanotic heart disease who were becoming progressively cyanotic and polycythemic (hemoglobin 17.9 +/- 1.1 g/dl) because of discrete shunt stenosis at the site of pulmonary anastomosis. Balloon diameters selected were equal to or within 1 mm of the unobstructed proximal shunt diameter. Before balloon dilation the diameter at the site of the stenosis was 2.8 +/- 0.8 mm (range 1.7 to 4); after balloon dilation it was 5.7 +/- 1.1 mm (range 4.5 to 7.5). The diameter increased in all patients (range 2.0 to 3.5 mm); the mean increase was 2.8 +/- 0.2 mm (p less than 0.005). Expressed as a percent, the increase in diameter at the stenosis ranged from 80% to 182.4% (mean 108.2 +/- 16.8%). Before balloon dilation the systemic oxygen saturation was 72.8 +/- 9.2% (range 55% to 80%) and after balloon dilation it was 83.6 +/- 2.9% (range 80% to 87%). A satisfactory increase (range 6% to 25%) in blood oxygen saturation was seen in all patients; the mean increase was 10.8 +/- 3.2% (p less than 0.01). At follow-up, the oxygen saturation by pulse oximetry was 85.8 +/- 2.9% (mean 5.8 +/- 1.7 months after balloon dilation) and the hemoglobin was 15.6 +/- 1.9 g/dl (mean 6.6 +/- 1.5 months after balloon dilation).(ABSTRACT TRUNCATED AT 250 WORDS)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.