The use of a target hemoglobin level of 13.5 g per deciliter (as compared with 11.3 g per deciliter) was associated with increased risk and no incremental improvement in the quality of life. (ClinicalTrials.gov number, NCT00211120 [ClinicalTrials.gov].).
Trials of anemia correction in chronic kidney disease have found either no benefit or detrimental outcomes of higher targets. We did a secondary analysis of patients with chronic kidney disease enrolled in the Correction of Hemoglobin in the Outcomes in Renal Insufficiency trial to measure the potential for competing benefit and harm from achieved hemoglobin and epoetin dose trials. In the 4 month analysis, significantly more patients in the high-hemoglobin compared to the low-hemoglobin arm were unable to achieve target hemoglobin and required high-dose epoetin-α. In unadjusted analyses, the inability to achieve a target hemoglobin and high-dose epoetin-α were each significantly associated with increased risk of a primary endpoint (death, myocardial infarction, congestive heart failure or stroke). In adjusted models, high-dose epoetin-α was associated with a significant increased hazard of a primary endpoint but the risk associated with randomization to the high hemoglobin arm did not suggest a possible mediating effect of higher target via dose. Similar results were seen in the 9 month analysis. Our study demonstrates that patients achieving their target had better outcomes than those who did not; and among subjects who achieved their randomized target, no increased risk associated with the higher hemoglobin goal was detected. Prospective studies are needed to confirm this relationship and determine safe dosing algorithms for patients unable to achieve target hemoglobin.
Pulse pressure is associated with risk of death in a large, nationally representative sample of patients undergoing maintenance hemodialysis. The recognition of pulse pressure as an important correlate of mortality in patients receiving dialysis highlights the need to investigate the relationship between potential therapeutic implications of conduit vessel function and clinical outcomes in patients with end-stage renal disease.
Background— Outcomes in patients with mild to moderate renal function (RF) abnormalities presenting with acute coronary syndromes (ACS) are not well defined. Methods and Results— A convenience sample of 4 ACS trial databases including all enrolled patients was assessed to determine 30- and 180-day outcomes. The 4 trials were Global Use of Strategies to Open Occluded Coronary Arteries (GUSTO) IIb, GUSTO-III, Platelet Glycoprotein IIb/IIIa in Unstable Angina: Receptor Suppression Using Integrilin Therapy (PURSUIT), and Platelet IIb/IIIa Antagonism for the Reduction of Acute coronary syndrome events in a Global Organization Network (PARAGON-A). Patients were stratified into ST-segment elevation (STE) and non–ST-segment elevation (NSE) groups and by the presence or absence of abnormal RF (creatinine clearance <70 mL/min). In the STE group, 7670 of 18 621 patients (41%) had abnormal RF. In the NSE group, 8152 of 19 304 (42%) had abnormal RF. Patients with abnormal RF were older, more often female, and more likely to have adverse baseline characteristics. They had higher mortality and higher mortality/nonfatal myocardial infarction (MI) at both 30 and 180 days, regardless of ST-segment status. Creatinine clearance was independently associated with risk of mortality (hazard ratio 0.79 in the STE group and 0.81 in the NSE group) and with risk of mortality/MI (hazard ratio 0.93) in the NSE group at 180 days. Conclusions— Patients presenting with ACS frequently have abnormal RF. Abnormal RF is a marker of adverse baseline clinical characteristics and is independently associated with increased risk of death and death/MI.
The relationship between blood pressure (BP) and clinical outcomes among hemodialysis patients is complex and incompletely understood. This study sought to assess the relationship between blood pressure changes with hemodialysis and clinical outcomes during a 6-month period. This study is a secondary analysis of the Crit-Line Intradialytic Monitoring Benefit Study, a randomized trial of 443 hemodialysis subjects, designed to determine whether blood volume monitoring reduced hospitalization. Logistic regression was used to estimate the association between BP changes with hemodialysis (Deltasystolic blood pressure=postdialysis-predialysis systoic BP (SBP) and the primary outcome of non-access-related hospitalization and death. Subjects whose systolic blood pressure fell with dialysis were younger, took fewer blood pressure medications, had higher serum creatinine, and higher dry weights. After controlling for baseline characteristics, lab variables, and treatment group, subjects whose SBP remained unchanged with hemodialysis (N=150, DeltaSBP -10 to 10 mm Hg) or whose SBP rose with hemodialysis (N=58, DeltaSBP > or =10 mm Hg) had a higher odds of hospitalization or death compared to subjects whose SBP fell with hemodialysis (N=230, DeltaSBP < or =-10 mm Hg) (odds ratio: 1.85, confidence interval: 1.15-2.98; and odds ratio: 2.17, confidence interval: 1.13-4.15). Subjects whose systolic blood pressure fell with hemodialysis had a significantly decreased risk of hospitalization or death at 6 months, suggesting that hemodynamic responses to dialysis are associated with short-term outcomes among a group of prevalent hemodialysis subjects. Further research should attempt to elucidate the mechanisms behind these findings.
Complications related to inadequate volume management are common during hemodialysis. This trial tested the hypothesis that availability of an intradialytic blood volume monitoring (IBVM) device improves fluid removal, reducing morbidity. A six-center, randomized trial with 6 mo of intervention comparing IBVM using Crit-Line versus conventional clinical monitoring was conducted. The average rate of non-access-related hospitalizations was compared across treatment groups using Poisson regression. Mortality analysis used the Kaplan Meier method. A total of 227 patients were randomized to Crit-Line, and 216 were randomized to conventional monitoring. Both groups had similar baseline characteristics. During the study, no differences in weight, BP, or number of dialysis-related complications were observed. There were 120 and 81 non-access-related hospitalizations in the Crit-Line and conventional monitoring groups. The adjusted risk ratio for non-access-related and access-related hospitalization was 1.61 (95% confidence interval 1.15 to 2.25; P ؍ 0.01) and 1.52 (95% confidence interval 1.02 to 2.28; P ؍ 0.04) for the Crit-Line monitoring group. Mortality was 8.7% in the Crit-Line monitoring group and 3.3% in the conventional group (P ؍ 0.021). Standardized mortality ratios comparing the Crit-Line and conventional monitoring groups to the prevalent hemodialysis population were 0.77 (NS) and 0.26 (P < 0.001). Hospitalization rates were 1.51 and 1.03 events/yr in the Crit-Line and standard monitoring groups, compared with 2.01 for the prevalent hemodialysis population. IBVM was associated with higher nonvascular and vascular access-related hospitalizations and mortality compared with conventional monitoring. The atypically low hospitalization and mortality rates for the conventional monitoring group suggest that these findings should be generalized to the US hemodialysis population with caution.
An increased neutrophil count is strongly associated with, and reduced lymphocyte count associated less strongly with, many surrogates of both malnutrition and inflammation. An increased neutrophil count and reduced lymphocyte count are independent predictors of increased mortality risk in haemodialysis patients.
ABSTRACT. Cardiovascular disease is an important cause of mortality among patients with chronic kidney disease (CKD). This study describes associations between CKD, cardiac revascularization strategies, and mortality among patients with CKD and cardiovascular disease. All patients undergoing cardiac catheterization at Duke University Medical Center (1995 to 2000) with documented stenosis ≥75% of at least one coronary artery and available creatinine data were included. CKD was staged using creatinine clearance (CrCl) derived from the Cockcroft-Gault formula (normal, ≥90 ml/min; mild, 60 to 89 ml/min; moderate, 30 to 59 ml/min; severe, 15 to 29 ml/min). Cox proportional-hazard regression estimated the relationship between clinical variables, including CrCl and percutaneous coronary artery intervention (PCI), coronary artery bypass grafting (CABG), medical management, and patient survival. There were 4584 patients included, and 24% had CrCl <60 ml/min. Each 10-ml/min decrement in CrCl was associated with an increase in mortality (hazard ratio, 1.14; P < 0.0001). CABG was associated with a survival benefit among patients with both normal renal function and patients with CKD compared with medical management. In patients with normal renal function, CABG was not associated with survival benefit over PCI. However, in patients with CKD, CABG was associated with improved survival. PCI was associated with a survival benefit compared with medical management among patients with normal, mildly, and moderately impaired renal function. Among patients with severe CKD, PCI was not associated with improved survival. CABG is associated with greater mortality reduction than PCI in severe CKD. E-mail: dreddan@eircom.net
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.