The diagnosis of endocarditis related to PM-lead infection should be suspected in the presence of fever, complications, or pulmonary lesions after PM insertion. Transesophageal echocardiography should be performed to look for vegetations. Staphylococci are involved in the majority of these infections. The endocardial system must be entirely removed and appropriate antibiotic therapy pursued for 6 weeks.
AimsThe ECOST trial examined prospectively the long-term safety and effectiveness of home monitoring (HM) of implantable cardioverter defibrillators (ICD).Methods and resultsThe trial's primary objective was to randomly compare the proportions of patients experiencing ≥1 major adverse event (MAE), including deaths from all causes, and cardiovascular, procedure-related, and device-related MAE associated with HM (active group) vs. ambulatory follow-ups (control group) in a sample of 433 patients. The 221 patients assigned to the active group were seen once a year, unless HM reported an ICD dysfunction or a clinical event requiring an ambulatory visit, while the 212 patients in the control group underwent ambulatory visits every 6 months. The characteristics of the study groups were similar. Over a follow-up of 24.2 months, 38.5% of patients in the active and 41.5% in the control group experienced ≥1 MAE (P < 0.05 for non-inferiority). The overall number of shocks delivered was significantly lower in the active (n = 193) than in the control (n = 657) group (P < 0.05) and the proportion of patients who received inappropriate shocks was 52% lower in the active (n = 11) than in the control (n = 22) group (P < 0.05). At the end of the follow-up, the battery longevity was longer in the active group because of a lower number of capacitor charges (499 vs. 2081).ConclusionOur observations indicate that long-term HM of ICD is at least as safe as standard ambulatory follow-ups with respect to a broad spectrum of MAE. It also lowered significantly the number of appropriate and inappropriate shocks delivered, and spared the device battery.Clinical trials registrationNCT00989417.
The results of this multicenter study demonstrate the high acute success rate and a low complication rate of irrigated tip catheter ablation of all clinical relevant VTs in remote myocardial infarction. However, during the follow-up a relevant number of recurrences occurred.
Background: To determine whether local complications at the site of pacemaker implantation indicate infection of the intravascular part of the lead as well as of the pacemaker pocket. Methods: 105 patients admitted for local inflammatory findings, impending pacemaker or lead exteriorisation, frank pacemaker or lead exteriorisation, or overt infection were studied prospectively. After systematic lead extraction, the initial clinical presentation was related to the results of lead cultures. Results: Regardless of the initial presentation, the intravascular parts of the leads gave positive cultures in 79.3% of patients. Additionally, 91.6% of the cultures of the extravascular lead segments were positive, in contrast to 38.1% positivity for wound swab cultures. No clinical observations or laboratory investigations permitted identification of patients with negative lead cultures. In a subgroup of 50 patients with manifestations strictly limited to the pacemaker implantation site, cultures of intravascular lead segments were positive in 72%. Infection recurred in 4/8 patients without complete lead body extraction (50%) v 1/97 patients (1.0%) whose leads were totally extracted (p , 0.001). Conclusions: Local complications at the site of pacemaker implantation are usually associated with infection of the intravascular part of the leads, with a risk of progressing to systemic infection. Such local symptoms should prompt the extraction of leads even in the absence of other infectious manifestations.
Background-The reentrant mechanism of postinfarct ventricular tachycardia (VT) has been documented by surgical mapping analysis, but little is known about postinfarct VT circuits and the characteristics of their related protected isthmus with the use of 3D catheter mapping systems. Methods and Results-A 3D electroanatomic mapping was performed in 21 patients with well-tolerated, postinfarct, sustained VT. In total, 33 episodes of tachycardia (mean cycle length 432Ϯ74 ms) were induced and mapped. Complete maps demonstrated macroreentrant circuits with 1 loop (nϭ8) or 2 loops (nϭ25) rotating around a protected isthmus bounded by 2 approximately parallel conduction barriers that consisted of a line of double potentials, a scar area, or the mitral annulus. A total of 26 critical isthmi were identified for the 33 VTs mapped, with the same isthmus being shared by 2 to 4 different tachycardic morphologies in 5 patients. On average, isthmi were 31Ϯ7 mm long (ranging from 18 to 41 mm) and 16Ϯ8 mm wide (ranging from 6 to 36 mm) and harbored diastolic electrograms. The isthmus axis was oriented parallel to the mitral annulus plane in perimitral circuits and perpendicular to the mitral annulus plane in all other circuits. Linear radiofrequency ablation performed across the most accessible part of the isthmus prevented the recurrence of tachycardia in 19 patients (90%) with a follow-up at 16Ϯ8 months.
Conclusions-Detailed
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.