The study is focused on correlation of isotherms derived from thermal images with an isodoses describing treatment plan for patients with breast cancer treated by radiotherapy. The irradiated area covered the part of the body after mastectomy. The study included patients diagnosed with breast cancer who were qualified for radiotherapy treatment. All patients were monitored during each treatment week during the entire radiotherapy process. The measurements were made under strictly defined conditions. In the treatment planning system (TPS), the specific plan was created for each patient. Spatial dose distribution in the patient’s body was obtained and presented by the isodoses (lines connecting points with the same dose values). The following areas from the treatment planning system were plotted on the thermograms: target (tumor area) and isodose: 45 Gy, 40 Gy, 30 Gy, 20 Gy and 10 Gy. The obtained results indicated a high correlation between magnitude of the dose represented as the isodose and the temperature of the treated skin. Moreover, preliminary analysis showed a repeatable increase of the mean temperature in the irradiated area during the treatment.
The aim of the study was to use thermal imaging to evaluate long-term chest temperature changes in patients who had previously been treated with radiotherapy. The examination with a thermal imaging camera involved 144 women—48 of them were patients after RT, 48 were females before breast cancer radiotherapy and the last group of participants were 48 healthy women. All patients (before and after radiotherapy) were divided into women after mastectomy and those after conservative surgery. In addition, the first group of women, those who had received radiotherapy, were divided into three other groups: up to 1 year after RT, over 1 year and up to 5 years after RT and over 5 years after RT. Due to this, it was possible to compare the results and analyse the differences between the temperature in the healthy and treated breasts. The comparison of obtained temperature results showed that the area treated by ionizing radiation is characterized by a higher temperature even a few years after the finished treatment. It is worth mentioning that despite the fact that the difference was visible on the thermograms, the patients had no observable skin lesion or change in color at the treatment site. For the results of the study provided for the group of healthy patients, there were no significant differences observed between the average temperatures in the breasts. The use of thermal imaging in the evaluation of skin temperature changes after radiotherapy showed that the average temperature in the treated breast area can change even a long time after treatment.
The accuracy of radiotherapy is the subject of continuous discussion, and dosimetry methods, particularly in dynamic techniques, are being developed. At the same time, many oncology centers develop quality procedures, including pretreatment and online dose verification and proper patient tracking methods. This work aims to present the possibility of using portal dosimetry in the assessment of radiotherapy repeatability. The analysis was conducted on 74 cases treated with dynamic techniques. Transit dosimetry was made for each collision‐free radiation beam. It allowed the comparison of summary fluence maps, obtained for fractions with the corresponding summary maps from all other treatment fractions. For evaluation of the compatibility in the fluence map pairs (6798), the gamma coefficient was calculated. The results were considered in four groups, depending on the used radiotherapy technique: stereotactic fractionated radiotherapy, breath‐hold, free‐breathing, and conventionally fractionated other cases. The chi2 or Fisher's exact test was made depending on the size of the analyzed set and also Mann–Whitney U‐test was used to compare treatment repeatability of different techniques. The aim was to test whether the null hypothesis of error‐free therapy was met. The patient is treated repeatedly if the P‐value in all the fluence maps sets is higher than the level of 0.01. The best compatibility between treatment fractions was obtained for the stereotactic technique. The technique with breath‐holding gave the lowest percentage of compliance of the analyzed fluence pairs. The results indicate that the repeatability of the treatment is associated with the radiotherapy technique. Treated volume location is also an essential factor found in the evaluation of treatment accuracy. The EPID device is a useful tool in assessing the repeatability of radiotherapy. The proposed method of fluence maps comparison also allows us to assess in which therapeutic session the patient was treated differently from the other fractions.
The aim of the study was to evaluate the temperature parameter of the breast area in patients undergoing radiotherapy at various intervals. The relationship between temperature changes on the patient’s skin and the time after the end of radiotherapy was studied. Measurements with a thermal imaging camera were performed in a group of twelve volunteers. Six of them were healthy women who did not have thermal asymmetry between the breasts, whereas six were diagnosed with breast cancer and underwent mastectomy due to the advanced stage of the disease. The patients were qualified for radiation therapy. Thermographic examinations were performed before treatment, two months later and then six months after the end of the treatment. Temperature differences between the healthy breasts and the treated areas were assessed. Additionally, the correlation between a patient’s skin temperature changes and the time after the end of radiotherapy was analyzed. The highest skin temperature increase (1.47 °C) was observed 6 months after the end of RT compared to the measurement before treatment. It seems that thermovision may bring a new tool for quantitative analyses of the temperature effects of radiotherapy.
Biomedical accelerators used in radiotherapy are equipped with detector arrays which are commonly used to obtain the image of patient position during the treatment session. These devices use both kilovolt and megavolt x-ray beams. The advantage of EPID (Electronic Portal Imaging Device) megavolt panels is the correlation of the measured signal with the calibrated dose. The EPID gives a possibility to verify delivered dose. The aim of the study is to answer the question whether EPID can be useful as a tool for interfraction QC (quality control) of dose and geometry repeatability. The EPID system has been calibrated according to the manufacturer’s recommendations to obtain a signal and dose values correlation. Initially, the uncertainty of the EPID matrix measurement was estimated. According to that, the detecting sensitivity of two parameters was checked: discrepancies between the planned and measured dose and field geometry variance. Moreover, the linearity of measured signal-dose function was evaluated. In the second part of the work, an analysis of several dose distributions was performed. In this study, the analysis of clinical cases was limited to stereotactic dynamic radiotherapy. Fluence maps were obtained as a result of the dose distribution measurements with the EPID during treatment sessions. The compatibility of fluence maps was analyzed using the gamma index. The fluence map acquired during the first fraction was the reference one. The obtained results show that EPID system can be used for interfraction control of dose and geometry repeatability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.