Among patients with unstable angina or myocardial infarction without ST-segment elevation, prasugrel did not significantly reduce the frequency of the primary end point, as compared with clopidogrel, and similar risks of bleeding were observed. (Funded by Eli Lilly and Daiichi Sankyo; TRILOGY ACS ClinicalTrials.gov number, NCT00699998.).
BackgroundThe unanticipated di icult airway is a potentially life-threatening event during anaesthesia or acute conditions. An unsuccessfully managed upper airway is associated with serious morbidity and mortality. Several bedside screening tests are used in clinical practice to identify those at high risk of di icult airway. Their accuracy and benefit however, remains unclear. ObjectivesThe objective of this review was to characterize and compare the diagnostic accuracy of the Mallampati classification and other commonly used airway examination tests for assessing the physical status of the airway in adult patients with no apparent anatomical airway abnormalities. We performed this individually for each of the four descriptors of the di icult airway: di icult face mask ventilation, di icult laryngoscopy, di icult tracheal intubation, and failed intubation. Search methodsWe searched major electronic databases including CENTRAL, MEDLINE, Embase, ISI Web of Science, CINAHL, as well as regional, subject specific, and dissertation and theses databases from inception to 16 December 2016, without language restrictions. In addition, we searched the Science Citation Index and checked the references of all the relevant studies. We also handsearched selected journals, conference proceedings, and relevant guidelines. We updated this search in March 2018, but we have not yet incorporated these results. Selection criteriaWe considered full-text diagnostic test accuracy studies of any individual index test, or a combination of tests, against a reference standard. Participants were adults without obvious airway abnormalities, who were having laryngoscopy performed with a standard laryngoscope and the trachea intubated with a standard tracheal tube. Index tests included the Mallampati test, modified Mallampati test, Wilson risk score, thyromental distance, sternomental distance, mouth opening test, upper lip bite test, or any combination of these. The target condition was di icult airway, with one of the following reference standards: di icult face mask ventilation, di icult laryngoscopy, di icult tracheal intubation, and failed intubation. Airway physical examination tests for detection of di icult airway management in apparently normal adult patients (Review)
Although bedside screening tests are routinely used to identify people at high risk of having a difficult airway, their clinical utility is unclear. We estimated the diagnostic accuracy of commonly used bedside examination tests for assessing the airway in adult patients without apparent anatomical abnormalities scheduled to undergo general anaesthesia. We searched for studies that reported our pre-specified bedside index screening tests against a reference standard, published in any language, from date of inception to 16 December 2016, in seven bibliographic databases. We included 133 studies (127 cohort type and 6 case-control) involving 844,206 participants. Overall, their methodological quality (according to QUADAS-2, a standard tool for assessing quality of diagnostic accuracy studies) was moderate to high. Our pre-specified tests were: the Mallampati test (6 studies); modified Mallampati test (105 studies); Wilson risk score (6 studies); thyromental distance (52 studies); sternomental distance (18 studies); mouth opening test (34 studies); and the upper lip bite test (30 studies). Difficult facemask ventilation, difficult laryngoscopy, difficult intubation and failed intubation were the reference standards in seven, 92, 50 and two studies, respectively. Across all reference standards, we found all index tests had relatively low sensitivities, with high variability, but specificities were consistently and markedly higher than sensitivities. For difficult laryngoscopy, the sensitivity and specificity (95%CI) of the upper lip bite test were 0.67 (0.45-0.83) and 0.92 (0.86-0.95), respectively; upper lip bite test sensitivity (95%CI) was significantly higher than that for the mouth opening test (0.22, 0.13-0.33; p < 0.001). For difficult tracheal intubation, the modified Mallampati test had a significantly higher sensitivity (95%CI) at 0.51 (0.40-0.61) compared with mouth opening (0.27, 0.16-0.41; p < 0.001) and thyromental distance (0.24, 0.12-0.43; p < 0.001). Although the upper lip bite test showed the most favourable diagnostic test accuracy properties, none of the common bedside screening tests is well suited for detecting unanticipated difficult airways, as many of them are missed.
Aim: Prior studies suggest that the use of personal protective equipment might impair the quality of critical care. We investigated the influence of personal protective equipment on out-of-hospital cardiopulmonary resuscitation. Methods: Randomised controlled non-inferiority triple-crossover study. Forty-eight emergency medical service providers, randomized into teams of two, performed 12 min of basic life support (BLS) on a manikin after climbing 3 flights of stairs. Three scenarios were completed in a randomised order: Without personal protective equipment, with personal protective equipment including a filtering face piece (FFP) 2 mask with valve, and with personal protective equipment including an FFP2 mask without valve. The primary outcome was mean depth of chest compressions with a pre-defined non-inferiority margin of 3.5 mm. Secondary outcomes included other measurements of CPR quality, providers' subjective exhaustion levels, and providers' vital signs, including end-tidal CO 2. Results: Differences regarding the primary outcome were well below the pre-defined non-inferiority margins for both control vs. personal protective equipment without valve (absolute difference 1 mm, 95% CI [À1, 2]) and control vs. personal protective equipment with valve (absolute difference 1 mm, [À0.2, 2]). This was also true for secondary outcomes regarding quality of chest compressions and providers' vital signs including etCO 2. Subjective physical strain after BLS was higher in the personal protective equipment groups (Borg 4 (SD 3) without valve, 4 (SD 2) with valve) than in the control group (Borg 3 (SD 2)). Conclusion: PPE including masks with and without expiration valve is safe for use without concerns regarding the impairment of CPR quality.
Low quality of evidence suggests that off-label use of ESAs may reduce mortality in a critical care setting. There was a lack of high-quality evidence about the harm of ESAs in critically-ill people. The information for biosimilar ESAs is less conclusive. Most studies neither evaluated ESAs' harm as a primary outcome nor predefined adverse events. Any further studies of ESA should address the quality of evaluating, recording and reporting of adverse events.
Background The COVID-19 pandemic led to widespread use of personal protection equipment (PPE), including filtering face piece (FFP) masks, throughout the world. PPE. Previous studies indicate that PPE impairs neurocognitive performance in healthcare workers. Concerns for personnel safety have led to special recommendations regarding basic life support (BLS) in patients with a potential SARS-CoV-2 infection, including the use of PPE. Established instruments are available to assess attention and dexterity in BLS settings, respectively. We aimed to evaluate the influence of PPE with different types of FFP masks on these two neuropsychological components of EMS personnel during BLS. Methods This was a randomized controlled non-inferiority triple-crossover study. Teams of paramedics completed three 12-min long BLS scenarios on a manikin after having climbed three flights of stairs with equipment, each in three experimental conditions: (a) without pandemic PPE, (b) with PPE including a FFP2 mask with an expiration valve and (c) with PPE including an FFP2 mask without an expiration valve. The teams and intervention sequences were randomized. We measured the shift in concentration performance using the d2 test and dexterity using the nine-hole peg test (NHPT). We compared results between the three conditions. For the primary outcome, the non-inferiority margin was set at 20 points. Results Forty-eight paramedics participated. Concentration performance was significantly better after each scenario, with no differences noted between groups: d2 shift control versus with valve − 8.3 (95% CI − 19.4 to 2.7) points; control versus without valve − 8.5 (− 19.7 to 2.7) points; with valve versus without valve 0.1 (− 11.1 to 11.3) points. Similar results were found for the NHPT: + 0.3 (− 0.7 to 1.4), − 0.4 (− 1.4 to 0.7), 0.7 (− 0.4 to 1.8) s respectively. Conclusion Attention increases when performing BLS. Attention and dexterity are not inferior when wearing PPE, including FFP2 masks. PPE should be used on a low-threshold basis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.