Background The need for permanent pacemaker (PPM) implantation is a common complication after transcatheter aortic valve replacement (TAVR). Deep implantation position is a risk factor for PPM implantation. Thus, in the field of self-expandable (SE) transcatheter heart valves (THV) cusp overlap projection (COP) technique was implemented to reduce parallax, allowing a more precise guidance of implantation depth. Aims This meta-analysis aims to report the outcome of patients undergoing TAVR with SE THV using COP versus conventional implantation technique (CIT). Methods Systematical search in MEDLINE and EMBASE yielded five observational controlled studies comparing both implantation techniques for the SE Evolut prosthesis (Medtronic Intern. Ltd., CA, USA) and fulfilling the inclusion criteria for meta-analysis. Results Totally, 1227 patients were included, comprising 641 who underwent COP and 586 CIT TAVR. Incidence of post-procedural need for PPM implantation was significantly lower in COP group (9.8% vs 20.6%; OR = 0.43; p < 0.00001). This was accompanied by significantly higher implantation position in COP group (mean difference distance from distal end of the intraventricular portion of the THV to the non-coronary cusp (NCC): − 1.03 mm; p = 0.00001). Incidence of new-onset left bundle branch block did not differ. Regarding procedural and 30-day mortality, technical success, post-procedural aortic regurgitation, and rates of multiple device implantation, no difference between COP and CIT was found. Conclusion COP is an effective and safe implantation technique to reduce the need for a permanent pacemaker implantation during TAVR with SE Evolut prosthesis. Graphical abstract
Background The exact incidence and predictors of new-onset atrial fibrillation (AF) after percutaneous closure of patent foramen ovale (PFO) are unknown. Objective We sought to find post-procedural AF incidence rates and differences due to different screening strategies and devices. Methods A systematic search was conducted in Cochrane, MEDLINE and EMBASE. Controlled trials fulfilling the inclusion criteria were included into this meta-analysis. The incidence of new-onset AF was the primary outcome. Further parameters were surveillance strategy, device type, AF treatment and neurological events. New AF was determined as early onset within one month after implantation and late thereafter. Results 8 controlled trials and 16 cohort studies were eligible for quantitative analysis. 7643 patients received percutaneous PFO closure after cryptogenic stroke or transient ischaemic attack, 117 with other indications, whereas 1792 patients formed the control group. Meta-analysis of controlled trials showed an AF incidence of 5.1% in the interventional and 1.6% in the conservative arm, respectively (OR 3.17, 95% CI 1.46–6.86, P = 0.03, I2 = 55%). 4.7% received high-quality surveillance strategy with Holter-ECG or Loop recorder whereby AF incidence was overall higher compared to the low-quality group with 12-lead ECG only (3.3–15% vs. 0.2–4.3%). Heterogeneous results on time of AF onset were found, limited by different follow-up strategies. CardioSEAL and Starflex seemed to have higher AF incidences in early and late onset with 4.5% and 4.2%, respectively. Conclusion Percutaneous PFO closure led to higher AF post-procedural incidence compared to the conservative strategy. Heterogeneity in surveillance and follow-up strategy limited the generalizability. Trial Registration Registered on PROSPERO (CRD42022359945). Graphical abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.