Purpose SPECT/CT is a hybrid imaging modality, which combines a 3D scintigraphy (SPECT) and a conventional computerised tomography (CT). SPECT/CT allows accurate anatomical localisation of metabolic tracer activity. It allows the correlation of surgical factors such as tunnel position and orientation with mechanical alignment, clinical outcome and biological factors. The purpose of this study was to investigate whether the SPECT/CT tracer uptake (intensity and distribution) correlates with the stability and laxity of the knee joint and the position and orientation of the tibial and femoral tunnels in patients after anterior cruciate ligament (ACL) reconstruction. Methods A consecutive series of knees (n066), with symptoms of pain and/or instability after ACL reconstruction were prospectively evaluated using clinical examination and 99mTc-HDP-SPECT/CT. Clinical laxity testing was performed using the Rolimeter (Ormed, Freiburg, Germany) including Lachman testing (0-2 mm, 3-5 mm, 6-10 mm, >10 mm), anterior drawer test (0-2 mm, 3-5 mm, 6-10 mm, >10 mm), pivot shift test (positive versus negative) and patientbased subjective instability (yes versus no).For analysis of SPECT/CT tracer uptake a previously validated SPECT/CT localisation scheme consisting of 17 tibial, nine femoral and four patellar regions on standardised axial, coronal, and sagittal slices was used. The tracer activity on SPECT/CT was localised and recorded using a 3D volumetric and quantitative analysis software.Mean, standard deviation, minimum and maximum of grading for each area of the localisation scheme were recorded. The position and orientation of the tibial and femoral tunnel was assessed using a previously published method on 3D-CT. Results Correlation of instability, pivot shift as well as clinical laxity testing with 99mTc-HDP-SPECT/CT tracer uptake intensity and distribution showed no significant correlation. 99mTc-HDP-SPECT/CT tracer uptake correlated significantly with the position and orientation of the ACL graft. A more horizontal femoral graft position showed significantly increased tracer uptake within the superior and posterior femoral regions. A more posteriorly-placed femoral insertion site showed significantly more tracer uptake within the femoral and tibial tunnel regions. A more vertical or a less medial tibial tunnel orientation showed significant increased uptake within the tibial and femoral tunnel regions. A more anterior tibial tunnel position showed significantly more tracer uptake in the femoral and tibial tunnel regions as well as the entire tibiofemoral joint. Conclusions SPECT/CT tracer uptake intensity and distribution showed a significant correlation with the femoral and tibial tunnel position and orientation in patients with symptomatic knees after ACL reconstruction. No correlation was found with stability or clinical laxity.Michael T. Hirschmann and Dominic Mathis contributed equally to this paper.
The SPECT/CT algorithm presented is highly reliable and clinically feasible. Combining the 3D-mechanical information on tunnel placement and attachment areas and the 3D metabolic data will be helpful in evaluating patients with pain after ACL reconstruction.
Background: The primary aim of this study is to assess characteristics of pain in patients with ongoing pain after total knee arthroplasty (TKA). The secondary aim of this study is to identify specific pain patterns and link these to underlying pathologies. Methods: A prospectively collected cohort of 97 painful primary TKA patients was retrospectively evaluated. All patients followed a standardized diagnostic algorithm, which led to a diagnosis that set the indication for revision surgery. Character, location, dynamics, and radiation of pain were systematically assessed and correlated with the underlying pathologies. Results: Most frequent pain characters were pricking/lancinating (45.7%), pinching/crushing, and dull/ heavy (38.6%); 89.5% of all patients localized their knee pain anteriorly; 48.1% reported pain aggravations by descending stairs. Radiating pain was reported in 14% of the patients. Patella-related problems (56.7%) and instability (52.6%) were the most frequent pathologies. Based on correlations between the characteristics 6 specific pain patterns were identified. The most outstanding ones include the following: pattern 1, instability is associated with jumping/shooting, pricking/lancinating and tugging/wrenching pain, and aggravated by chair raising and starting; pattern 6, pain aggravation by descending stairs is associated with anterior and lateral jumping/shooting, tingling/stinging and sharp/lacerating pain character, and TKA positioning and patella baja.
Conclusion:The assessment of painful TKA patients involving specific pain patterns help to further differentiate and define the clinical picture and ultimately the cause of a painful TKA. If the causes of the described complaints are known, a decision for a therapy can be made reliably and sustainably at an early stage before the state of pain becomes chronic.
Background
With the Persona® knee system a new polyethylene formulation incorporating vitamin-E which aims to reduce oxidation and maintain wear resistance was introduced. Although in-vitro studies have demonstrated positive effects of the vitamin-E antioxidants on UHMWPE, no retrieval study has looked at polyethylene damage of this system yet. It was the aim to investigate the in-vivo performance of this new design, by comparing it with its predecessor in retrieval analysis.
Methods
15 NexGen® and 8 Persona® fixed-bearing implants from the same manufacturer (Zimmer Biomet) were retrieved from two knee revision centres. For retrieval analysis, a macroscopic analysis of polyethylene using a peer-reviewed damage grading method was used (Hood-score). The roughness of all articulating metal components was measured using a contact profilometer. The reason(s) for TKA revision were recorded. Statistical analyses (t-test) were performed to investigate differences between the two designs.
Results
The mean Hood score for Persona® inserts was 109.3 and for NexGen® 115.1 without significant differences between the two designs. Results from the profilometer revealed that Persona® and NexGen® femoral implants showed an identical mean surface roughness of 0.14 μm. The Persona® tibial tray showed a significantly smoother surface (0.06 μm) compared to the NexGen® (0.2 μm; p < 0.001). Both Hood score and surface roughness were influenced by the reasons for revision (p < 0.01).
Conclusions
The bonding of the antioxidant vitamin-E to the PE chain used in the novel Persona® knee system does not reduce in-vivo surface damage compared to highly crosslinked PE without supplemented vitamin-E used in its predecessor knee system NexGen®. However, the Persona® titanium alloy tibial tray showed a significantly smoother surface in comparison to the NexGen® titanium alloy tibial tray. This study provides first retrieval findings of a novel TKA design and may help to understand how the new Persona® anatomic knee system performs in vivo.
Purpose
The diagnostic process in patients after painful total knee arthroplasty (TKA) is challenging. The more clinical and radiological information about a patient with pain after TKA is included in the assessment, the more reliable and sustainable the advice regarding TKA revision can be. The primary aim was to investigate the position of TKA components and evaluate bone tracer uptake (BTU) using pre-revision SPECT/CT and correlate these findings with previously published pain patterns in painful patients after TKA.
Methods
A prospectively collected cohort of 83 painful primary TKA patients was retrospectively evaluated. All patients followed a standardized diagnostic algorithm including 99m-Tc-HDP-SPECT/CT, which led to a diagnosis indicating revision surgery. Pain character, location, dynamics and radiation were systematically assessed as well as TKA component position in 3D-CT. BTU was anatomically localized and quantified using a validated localization scheme. Component positioning and BTU were correlated with pain characteristics using non-parametric Spearman correlations (p < 0.05).
Results
Based on Spearman’s rho, significant correlations were found between pain and patients characteristics and SPECT/CT findings resulting in nine specific patterns. The most outstanding ones include: Pattern 1: More flexion in the femoral component correlated with tender/splitting pain and patella-related pathologies. Pattern 3: More varus in the femoral component correlated with dull/heavy and tingling/stinging pain during descending stairs, unloading and long sitting in patients with high BMI and unresurfaced patella. Pattern 6: More posterior slope in the tibial component correlated with constant pain.
Conclusion
The results of this study help to place component positioning in the overall context of the "painful knee arthroplasty" including specific pain patterns. The findings further differentiate the clinical picture of a painful TKA. Knowing these patterns enables a prediction of the cause of the pain to be made as early as possible in the diagnostic process before the state of pain becomes chronic.
Level of evidence
Level III
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.